![FISCHBEIN Empress Series Operator'S Manual Download Page 28](http://html1.mh-extra.com/html/fischbein/empress-series/empress-series_operators-manual_2294109028.webp)
FISCHBEIN
®
MODELS 100 & 101 EMPRESS™ SERIES SEWING HEAD
OPERATOR’S MANUAL
REV. H 2005 / 11
27
Illustration 29
6. Refer to
Illustration 29
. Check the
parallelism of the new needle holder (
D
) using
the gauge (
F
) (part # 10230) where it is
parallel to the front edge of the throat plate.
Press the gauge flat against the screw (
E
).
7. If the needle holder (
D
) is not parallel, loosen
screw (
A
) in
Illustration 27
, and rotate the
needle holder (
C
) until it is parallel.
8. Tighten screw (
A
).
D =
needle holder
E =
screw to lock
needle
F =
Gauge (part #
10230)
X
Illustration 28