background image

OTDR-File Save

Press            (Save) key to save �ile after test 

complete, pop up the keyboard, enter the name of 

the �ile, and press Enter to save the �ile. If the 

automatic save (otdr) function is turned on in 
"System Settings", it will be saved automatically 
after the test complete without manual operation.

Auto-save function
Enter the system settings, open the auto-saving 
function, the instrument will automatically save the 

test �iles after the average or auto-test.

OTDR-File Operation

Press               to enter the �ile list. 

Press the          key to open a folder or File.

F1

Open �ile

F2

Delete �ile

F3

Rename �ile

F4

Return to the main menu

T h e   f u n c t i o n   c a n   b e   t e s t e d  
automatically by one key, and the 
information of the length of the link, 
the type of event point and the position 
of breakpoint can be displayed in a 
graphical form. The result is clear and 
easy to understand.

This function is used to test the power of 
optical signal and insertion loss of 
various devices and optoelectronic 
components. It can identify and measure 
the frequency of 270/330/1k/2kHz 
frequency optical signal.

F1: Switching wavelength
F2: Setting Reference Power
F3: Zero Reference Power
F4: Enter the Calibration Mode

Absolute power, relative power and 
linear power are converted as follows:
P

Abs.

=10lgP

Lin.

/1mW

P

Rel.

=P 

Abs.

-P

Ref.

2019-04-26

14:00

Wave

Reference

Ref-Zero

CAL

OPM

-29.87

dBm

OPM

1310nm

-50.00dBm

26.00dBm

0.0 dB

Ref. Pow:

1.0 mw

Lin. Pow:

cw/1 kHz

Frequency:

Ref :0.00  dBm

Visible red light (650 nm) is injected into the 

optical �iber, and the position of the optical 
�iber fault point can be judged conveniently 

and accurately by observing the leakage 

position on the measured �iber. It is suitable 
for the detection of bare optical �ibers, 

jumpers and other high loss sections caused 
by near-end faults and micro-bending of 

optical �ibers and cables which can leak red 

light.
Avoid looking directly at the laser output port. 
Laser can cause damage to human retina.

F1

Open VFL

F2

VFL �lash at 1 Hz

F3

VFL �lash at 2 Hz

F4

Turn off VFL

 

The wavelength of stabilized laser source is 
the same as OTDR wavelength. It is used to 
measure the parameters of telecommunica-
tion, CATV, LAN cable, insertion loss, isola-
tion loss and echo loss of optical passive 
devices, and wavelength responsiveness of 
detectors.

There are �ive modes of light source: CW, 

270 Hz, 330 Hz, 1 kHz and 2 kHz.

F1

Open LS

F2

Turn off LS

F3

Switch LS Wavelength

F4

Switch LS Mode

RJ45 line sequence measurement.

F1

Start Test

F3

Switch Line Sequence Test Standard

F4

Return to the main menu

RJ45 Line Tracker
Used for RJ45 cable length testing and wire 

tracker.After the line-�inding function is activat

-

ed, the cable being searched is touched by the 
distal end of the line-searching, and the sound of 
continuous "drops and drops" is heard.

RJ45 Line Length Test
F1: Start Line Length Test
F2: Switch Line Length Unit
F3: Switch Line Sequence Test Standard
F4: Start Line-tracker Function

Set up automatic shutdown, backlight brightness, time, 
language, upgrade and other information.

F1: Optional for switching the current menu
F3: System Software Upgrade

F4: Con�irmation settings

OTDR-File Save

9

F3

OTDR-File Operation

10

2019-04-26

14:00

20180328

20180327

20180326

20180325

20180322

20180324

20180323

FOLDER

Open

Del

Rename

Back

F2

F3

F4

F1

F2

F3

F4

F1

F4

OK

iLOM(Event Map)

11

OPM

12

F2

F3

F4

F1

VFL

13

2019-04-26

14:00

Set

Save

File

OTDR

NK700-39

5.201

3.82

Km

Link Length

Link Loss

dB

0.25

Average Loss

dB/km

45.2

Return Loss

dB

Link quality

PASS/FAIL

start

END

5-1

5.201Km

5.201Km

5.201Km

0.5dB

2019-04-26

14:00

Normal

1 Hz

2 Hz

Close

VFL

650

nm

Avoid looking directly at the laser 

output port. Laser can cause damage to 

human retina.

DANGER

F2

F3

F4

F1

F2

F3

F4

F1

F2

F3

F4

F1

LS-Laser Source 

14

2019-04-26

14:00

Open

Close

Mode

Back

Optic Laser

Avoid looking directly at the 

laser output port. Laser can 

cause damage to human retina.

DANGER

CW/270/330/1k/2kHz

1550nm

Output Mode

F3

F4

F1

RJ45 Sequence

15

2019-04-26

14:00

Test

Standard

Back

Sequence Test:TIA-568B

Tips:

Please connect the remote device.
Click F1 for cable sequence test.

Port:1

Port:2

Port:3

Port:4

Port:5

Port:6

Port:7

Port:8

Port:1

Port:2

Port:3

Port:4

Port:5

Port:6

Port:7

Port:8

RJ45 Sequence

RJ45 Line Length & LineTracker

16

2019-04-26

14:00

Length

Unit

Standard

Tracker

Tips:

Click F1 for cable length test.
Click F4 for cable track test.

RJ45 Length:TIA-568B

Port:1

Port:2

Port:3

Port:4

Port:5

Port:6

Port:7

Port:8

200m

200m

200m

200m

200m

200m

200m

200m

Length&Tracker

System settings

17

2019-04-26

14:00

Set

Help

Update

OK

Auto OFF

Back Light

Beep

Language

Auto Save(OTDR)

USB Connection

Factory Data Reset

Version Information

10 Min

50%

English

Date

Time

2019-04-25

20:18:20

System

2019-04-26

14:00

PASS

A  0.000Km

B  10.057Km

Q W E R T Y U I O P

1 2 3 4 5 6 7 8 9 0

A S D F G H J K

Z X C V B N M

L

space

Enter

#

.

Save SOR

Del

OK

OK

Press left and right buttons to switch events

Link state

Link information

Link events

Current event information

Note:The function module is optional accessories.

Note:The function module is optional accessories.

exit

The Line-Tracker test is 

under way. Please use the 

r e m o t e   l i n e - � i n d i n g  

module to test and click 

the return key to exit.

Switch settings entry
Switch options of current entry

Reference Power

Absolute Power

Power Measurement Range 

Relative Power 

Linear Power 

Frequency Measurement

Status Indicator

Warning information

Mode

LS Information

Warning Information 

Test Results

Test Standard

Tips

Test Results

Test Standard

Tips

Len

Loss

Event

Reviews: