Connector 14 (CN14), 4-Pin (Optional Sensor Input)
This connector provides optional sensor inputs. Most commonly used with proximity and tilt sensors.
Pin 1 Black – Negative (-) ground.
Pin 2 Black/White - 2nd stage negative (-) input. (Instant trigger)
Pin 3 Red – 12V positive (+) output.
Pin 4 Grey/White - 1st stage negative (-) input. (Warn away)
Option Programming Tables
CM6000
Option Group 1
Feature
Default Setting - I
Optional Setting - II
Optional Setting - III
Optional Setting - IV
1-01
Unlock before, Lock after,
starting
Off
On
Lock After Remote
Start Only
Lock After Shutdown
Only
1-02
Lock / Unlock pulse duration
0.8 sec
2.5 sec
0.125 sec
3.5 sec
1-03
Driver's priority unlock
Off
On
1-04
Double pulse unlock
Off
On
1-05
Rearm Output
After Start Shutdown
and First Lock
After Start Shutdown
and Every Lock
After Start Only
After Shutdown Only
1-06
Reservation Lock
(Manual transmissions)
Locks When Reserva-
tion Mode is Set
Does Not Lock When
Reservation is Set
Reservation Sets 10
Seconds After the Last
Door is Closed
1-07
Unlock / Disarm With Trunk
Release
Unlock, Factory Dis-
arm, and Trunk Release
Factory Disarm, Trunk
Release Only
Trunk Release Only
1-08
Passive Mode
Off
Passive locking with
Passive Arming
No Passive Locking
with Passive Arming
1-09
Ignition controlled door locks
Off
On
RPM Locks (Tach
Sensing Mode Only)
1-10
Auto Relock
(If a door is not opened within
this amount of time)
Off
30 sec
60 sec
5 min
1-11
Ignition / Accessory Out Upon
Unlock
Off
Ignition Pulse - same
timing as disarm pulse
Acc Pulse - same tim-
ing as disarm pulse
Ignition and Acc
Pulse - same timing as
disarm pulse
1-13
Double Pulse Disarm Input
Single Pulse
Double Pulse
1-14
Auto Lock Mode
(2 Way International Remotes)
Off
On
1-15
Trunk Output Timing
1 sec
0.5 sec
2 sec