Solid fuel boiler - Maintain a constant temperature in 
heating circuit

M

M

Maintain a constant temperature of heat reservoir

UNI TEMP

UNI TEMP

UNI

TEMP

UNI TEMP

UNI TEMP

DTC100/2

M

Examples:

U

N

T

E

M

P

M

UNI

TEMP

ROTOTERM 

MR-TR

Maintain a constant temperature in 
sanitary water circuit

Floor heating - Maintain a 
constant temperature of 
heating circuit

Solar pool heating - Maintain a constant temperature of 
heating circuit

Floor heating regulation 
from radiator heating circuit

UNI TEMP 

UNI TEMP 

www.first.si

7

FIRŠT-ROTOTEHNIKA, s.p., 

Radegunda 54, 3330 Mozirje 
info@first.si, http://www.first.si

PE VELENJE: 

Koroška c. 56a, 3320 Velenje
tel: 03 / 898 35 00, fax: 03 /  898 35 35

In compliance with standards

All our products fulfil the essential safety and protection requirements for CE conformity marking according to the 
following directives

EMC dire

ctive: 2004/108/EEC

 / LV dire

ctive: 2006/95/EEC / PAH directive 2005/69/EEC.

In compliance with standards:

EN 60730-2-14

;

 1997 + A1:2001 + A11:2005 + A2:2008

EN60730-1:2000 + A12:2003 + A12:2004 + A14:2005 + A16:2007 + A2:2008
EN 55014-1:2006
EN 61000-3-2:2006
EN 61000-3-3:2006
EN 62233:2008
ZEK 01.2-08

We reserve the right to modify the instructions and the technical data of the product without prior notice.

Safety notes:

ź

The actuator has been designed for use in stationary heating, ventilation and air-

conditioning systems and is not allowed to be used outside the specified field of 
application, especially in aircraft or in any other airborne means of transport.

ź

Caution power supply voltage – 24VAC.

ź

It may only be installed by suitably trained personnel. All applicable legal or 

institutional installation regulations must be complied with.

ź

The device must be protected from moisture and is not recommended for use in 

external applications.

ź

The device may only be opened at the manufacturer's site. It does not contain any 

parts that can be replaced or repaired by the user.

ź

The cable must not be removed from the device.

ź

The device contains electrical and electronic components and is not allowed to be 

disposed of as household refuse. All locally valid regulations and requirements 
must be observed.

Recommended mounting position

Examples:

Summary of Contents for UNI TEMP Series

Page 1: ...ithout valve Enclosed mounting kit FIR T ROTOMIX ROTOMIX G ESBE VRG VRB ACASO TERMOMIX BARBERI FEROTERM PAW EURONORM ESBE IMP DANFOSS BESSER SELTRON LOVATO TUXHORN STRAWA CIMBERIO UNI TEMP is a consta...

Page 2: ...OMIX ROTOMIX G ESBE VRG VRB ACASO TERMOMIX BARBERI FEROTERM PAW EURONORM ESBE IMP DANFOSS BESSER SELTRON LOVATO TUXHORN STRAWA CIMBERIO 24V 50Hz UNI TEMP 24VAC UNI TEMP 230VAC 40 6 l 1 5m Sensor VF KT...

Page 3: ...t 58024 G ESBE VRG VRB ACASO TERMOMIX BARBERI FEROTERM PAW EURONORM ESBE IMP DANFOSS BESSER SELTRON LOVATO TUXHORN STRAWA CIMBERIO By special request 58025 SELTRON LOVATO PAW 58026 LAZZARI LANDIS 5802...

Page 4: ...libration is carried out ON 1 2 3 4 DIP switch settings ON 1 2 3 4 LED COM Xp Trimmer Xp is located inside controller To open the controller it is necessary to loosen the screws on the cover 3x and ha...

Page 5: ...red temperature 50 C Xp parameter proportional control range of valve 10K When the temperature is less than 45 controller gives continuous signal for opening mixing valve C When the temperature is bet...

Page 6: ...heat reservoir UNI TEMP UNI TEMP UNI TEMP UNI TEMP UNI TEMP DTC100 2 M Examples UNI TEMP Maintain a constant temperature in sanitary water circuit Floor heating Maintain a constant temperature of hea...

Page 7: ...and the technical data of the product without prior notice Safety notes The actuator has been designed for use in stationary heating ventilation and air conditioning systems and is not allowed to be...

Reviews: