Examples;

1

24...240V

50Hz

L

2

črpalka

3

N

1

blue

black CLOSE

grey OPEN

MV 120/...
EMV 110..

24...240V

50Hz

2 3

Electrical connection of the motorized ball valve EMV .. 110 series or
regulating motor MV 120 / ...

Electrical connection of the burner or circulation pump

Electrical connection of electric radiators and other heating appliances

ELECTRICAL CONNECTION

cx4-2210-Eltherm-TT6-v7-eng.cdr

16A/250VAC, cos =1

ϕ

10A/250VAC, cos =0.6

ϕ

Connection for electric boilers

ETK-SET, ETK SET U, ETK -
SET for pipe systems

TERMOMONT:

Room thermostat

TT6

16A/250VAC, cos =1

ϕ

10A/250VAC, cos =0.6

ϕ

Room thermostat

TT6

Boiler ETK-SET

1 2 3

Room thermostat

TT6

Connection for boilers using solid
fuel, oil
TKK, TKK3, TKU3, TŽK, TEMY,
CTK, BTK

TERMOMONT:

1 2 3

Room thermostat

TT6

pump

burner

room

thermostat

power

supply

Connection for electric boilers

ETK - SET ELEKTRONIK

TERMOMONT:

Boiler ETK-SET ELEKTRONIK

1 2 3

Room thermostat

TT6

4

1 2 3

Room

thermostat

TT6

heating appliance

Max. load:

* Resistive load

16A/250VAC, cos =1

max. 3 kW

φ

* Inductive load

10A/250VAC, cos =0.6

max. 2 kVA

φ

®

ELTHERM TT 6

USER-FRIENDLY PROGRAMMABLE THERMOSTAT

USER'S GUIDE

®

C. WIRING GUIDE

Follow the el. scheme which is printed on the terminal's
cover.

USER'S GUIDE

Choosing location for INSTALLATION

For obtaining thermostat's best performance upon using,
recommend user to follow up with precaution listed below.
(1). Place thermostat on wall inside the room approximate 1.5

meter above floor.

(2). Avoid position where temperature sensing easily

interfered by ambience, such as, directly exposed to
Sun-Light, too near to any Heat-Generate devices
/refrigerator, right next to entrance/exit/window, etc.

(3). Prevent thermostat from installed at position that

furniture may interfere air-flow, stagnant air-flow location
is not suitable for installing thermostat.

(4). Keep thermostat away from high humid ambience, high

humidity is hazardous to thermostat's operational
duration.

(5). It's crucial, before installing thermostat, make sure house

renovation is finished, no tacky painting/plaster is right
on thermostat's installing position.

(6). To level thermostat prior to installation is not necessary.
(7). Push excess cable wires back into the wall while

positioning thermostat. If there is a draft, pack the
opening with non-combustible material.

(8). Place batteries in thermostat requiring batteries,

observing

+

and

-

positions.

START INSTALLATION

(1). How to open top housing