Examples;
1
24...240V
50Hz
L
2
črpalka
3
N
1
blue
black CLOSE
grey OPEN
MV 120/...
EMV 110..
24...240V
50Hz
2 3
Electrical connection of the motorized ball valve EMV .. 110 series or
regulating motor MV 120 / ...
Electrical connection of the burner or circulation pump
Electrical connection of electric radiators and other heating appliances
ELECTRICAL CONNECTION
cx4-2210-Eltherm-TT6-v7-eng.cdr
16A/250VAC, cos =1
ϕ
10A/250VAC, cos =0.6
ϕ
Connection for electric boilers
ETK-SET, ETK SET U, ETK -
SET for pipe systems
TERMOMONT:
Room thermostat
TT6
16A/250VAC, cos =1
ϕ
10A/250VAC, cos =0.6
ϕ
Room thermostat
TT6
Boiler ETK-SET
1 2 3
Room thermostat
TT6
Connection for boilers using solid
fuel, oil
TKK, TKK3, TKU3, TŽK, TEMY,
CTK, BTK
TERMOMONT:
1 2 3
Room thermostat
TT6
pump
burner
room
thermostat
power
supply
Connection for electric boilers
ETK - SET ELEKTRONIK
TERMOMONT:
Boiler ETK-SET ELEKTRONIK
1 2 3
Room thermostat
TT6
4
1 2 3
Room
thermostat
TT6
heating appliance
Max. load:
* Resistive load
16A/250VAC, cos =1
max. 3 kW
φ
* Inductive load
10A/250VAC, cos =0.6
max. 2 kVA
φ
®
ELTHERM TT 6
USER-FRIENDLY PROGRAMMABLE THERMOSTAT
USER'S GUIDE
®
C. WIRING GUIDE
Follow the el. scheme which is printed on the terminal's
cover.
USER'S GUIDE
Choosing location for INSTALLATION
For obtaining thermostat's best performance upon using,
recommend user to follow up with precaution listed below.
(1). Place thermostat on wall inside the room approximate 1.5
meter above floor.
(2). Avoid position where temperature sensing easily
interfered by ambience, such as, directly exposed to
Sun-Light, too near to any Heat-Generate devices
/refrigerator, right next to entrance/exit/window, etc.
(3). Prevent thermostat from installed at position that
furniture may interfere air-flow, stagnant air-flow location
is not suitable for installing thermostat.
(4). Keep thermostat away from high humid ambience, high
humidity is hazardous to thermostat's operational
duration.
(5). It's crucial, before installing thermostat, make sure house
renovation is finished, no tacky painting/plaster is right
on thermostat's installing position.
(6). To level thermostat prior to installation is not necessary.
(7). Push excess cable wires back into the wall while
positioning thermostat. If there is a draft, pack the
opening with non-combustible material.
(8). Place batteries in thermostat requiring batteries,
observing
“
+
”
and
“
-
”
positions.
START INSTALLATION
(1). How to open top housing