First DTC 200/2G Installation Manual Download Page 1

1

FIRŠT-ROTOTEHNIKA, s.p., Radegunda 54, SI-3330 Mozirje, Slovenija

tel. +386 3 898 35 00, fax. +386 3 898 35 35, e-mail: [email protected], http://www.rototehnika-sp.si

DTC 200/2G

Differential thermostat can be used for:
- Heating sanitary water with possibility to control

the burner.

- Cooling living space with blowing the cool

outside air into the living space

INSTALLATION INSTRUCTIONS

P7-3603-22-DTC200-2-montaža

WARNING!

Installation instructions are meant for specialist. All examples
listed in the instructions are merely indicative. The manufacturer
accepts no responsibility for incorrect hydraulic connection of
machine parts of installations should comply with all safety
regulations defined by law and the rules. Carefully read the
instructions to make good use of the product.

INFORMATION FOR ORDER:

CODE

DTC 200/2G ..................................................................

13017

The set consists of:
Differential thermostat DTC 200/2G, sensor BSF1, sensor KF,
mounting kit, installation instructions and instruction for use

Tube TV2 ......................................................................

27080

(1/2", l=100mm, inner diameter 14mm)

INDEX:

Technical data ---------------------------------------------------------- 2
Testing sensors
Mounting the thermostat
Cables connection
Choosing the working regime -------------------------------------- 3

1. HEATING THE DOMESTIC HOT WATER FROM ONE HEATING
SOURCE (SOLAR COLLECTORS, BOILERS, HEAT PUMP...)
WITH CONTROLLING THE HEATING SOURCE (BURNER) --- 3

1.1 Basics
1.2 Operation
1.3 Sensors installation
1.4 Electrical connection --------------------------------------------- 4
1.5 Examples of use

2. HEATING THE DOMESTIC HOT WATER FROM ONE HEATING
SOURCE (SOLAR COLLECTORS, BOILERS, HEAT PUMP...)
WITH ADDITIONAL HEATING WITH ELECTRICAL HEATER -- 6

2.1 Basics
2.2 Operation
2.3 Sensors installation
2.4 Electrical connection
2.5 Examples of use --------------------------------------------------- 7

3. COOLING LIVING SPACE WITH BLOWING THE COOL
OUTSIDE AIR INTO THE LIVING SPACE

-------------------------- 8

2.1 Basics
2.2 Operation
2.3 Sensors installation
2.4 Examples of use
2.5 Electrical connection

WITH DIFFERENTIAL THERMOSTAT ARE THREE
POSSIBLE WAY OF USE:

1. HEATING THE DOMESTIC HOT WATER FROM ONE HEATING
SOURCE (SOLAR COLLECTORS, BOILERS, HEAT PUMP...)
WITH CONTROLLING THE HEATING SOURCE (BURNER).

Differential thermostat controls the electric motor actuated ball
valve (EMV 110..) and the circulation pump. If it necessary turns
ON or OFF the heating source (burner).

2. HEATING THE DOMESTIC HOT WATER FROM ONE HEATING
SOURCE (SOLAR COLLECTORS, BOILERS, HEAT PUMP...)
WITH ADDITIONAL HEATING WITH ELECTRICAL HEATER.

Differential thermostat controls the electric motor actuated ball
valve (EMV 110..) and the circulation pump. In case that the
primary heating source (solar collectors, boilers...) has not
enough energy, water in water tank is heated with electrical
heater.

3. COOLING LIVING SPACE WITH BLOWING THE COOL
OUTSIDE AIR INTO THE LIVING SPACE

Differential thermostat controls the ventilator.

We reserve the right to modify the instructions and the technical
data of the product without prior notice.

Summary of Contents for DTC 200/2G

Page 1: ...1 Basics 1 2 Operation 1 3 Sensors installation 1 4 Electrical connection 4 1 5 Examples of use 2 HEATINGTHEDOMESTICHOTWATERFROMONEHEATING SOURCE SOLAR COLLECTORS BOILERS HEAT PUMP WITHADDITIONALHEATI...

Page 2: ...gime Temperature diference setting 0K 15K Hysteresis of thermostat 1K 2K Temperature of ambient 0 C 40 C Outputs 2 relay outputs 230V 50Hz 6 1 A working contact SPST controlling the electric motor act...

Page 3: ...Heating sanitary water with possibility to control the burner Cooling living space with blowing the cool outside air into the living space If it s used for heating the jumpers must be in position sun...

Page 4: ...ng source burner The thermostat enables setting of two parameters 1 Regulation of maximum temperature in hot water tank from 5 to 85 C This temperature is defined by T2 sensor witch is generally mount...

Page 5: ...nnection for example 3 7 2W Electric motor actuated ball valve EMV 110 series 602 502 Jumperposition HEATING 1 5 EXAMPLES OF USE example 1 Heating sanitary water with solar collectors example 2 Heatin...

Page 6: ...ion you define how much the value of the source temperature collector boiler should exceed the temperature of water around the exchanger in hot water tank that the thermostat opens the valve and activ...

Page 7: ...by central heating water When energy of central heating water is too low the water in storage tank is after heated by el heater Jumperposition HEATING This action causes activity for only one heating...

Page 8: ...w much the value of the source temperature outside air should be lower than inside temperature that thermostat switches on the ventilator 3 2 OPERATION DTC 200 2G single differential thermostat measur...

Reviews: