11
1. General Operation:
When the system is operating, one of the three displays may be shown. Pressing
next
will alternate
between displays. One of the displays is always the current time of day. The second display shows
the current treated water flow rate through the system in Gallons Per Minute (gpm). The third display
shows the current volume remaining in Gallons. Capacity remaining is the gallons that will be treated
before the system goes through a regeneration cycle.
The user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at the preset time of regeneration, the words
REGEN TODAY
will appear on the display.
The softener
has an installed water meter, the word “Softening” flashes on the display when water is
being treated (i.e. water is flowing though the system).
2. Regeneration Mode:
When the system begins to regenerate, the display will change to
include information about the step of the regeneration process and
the time remaining for that step to be completed. The system runs
through the steps automatically and will reset itself when the
regeneration has been completed.
3. Manual Regeneration:
Sometimes there is a need to regenerate before the control valve calls for it. This may be needed if a
period of heavy water use is anticipated or when the system has been operated without salt.
To initiate a manual regeneration at the
preset delayed regeneration time, press
and release
regen
. The words “
REGEN
TODAY
” will flash on the display to
indicate that the system will regenerate at
the preset delayed regeneration time.
If you pressed the
regen
button in error,
pressing the button again will cancel the
command.
To initiate an immediate manual regeneration, press and hold the
regen
button for
three seconds. The system will begin to regenerate immediately. This command
cannot be cancelled.
4. Power Loss:
If the power goes out for less than two hours, the system will
automatically reset itself. If an extended power outage
occurs, the time of day will flash on and off which indicated
the time of day should be reset. The system will remember
all other settings.
Error Message:
If the word “ERROR” and a number are
alternately flashing on the display, record the number and contract the dealer for help. This indicates
that the control valve was not able to function properly.
Operating Displays