INSIDE THIS MANUAL

 

THIS USER’S MANUAL HAS BEEN RESIZED TO PRINT OUT ON 8-1/2 x 11” PAGES.

BLACK page numbers reference the original printed document.

RED page numbers reference this web version.

Other Features Of Smoke Alarms  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Special Compliance Considerations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Limitations Of Smoke Alarms  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Where To Install Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Where Not To Install Smoke Alarms  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Protecting Your Family From Fire  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

/3

What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Important! Read Before Installing This Smoke Alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
How To Install This Smoke Alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Weekly Testing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

/4

Regular Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
If This Smoke Alarm Goes Into Alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
If This Smoke Alarm Is Not Working Properly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

/5

10-Year Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

/5

 

All Rights Reserved. ©1999 BRK Brands, Inc. 
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: Monday-Friday, 7:30am-5pm (Central Time): (800) 323-9005 • Internet: www.firstalert.com

 

OTHER FEATURES OF SMOKE ALARMS

 

Battery (DC) operated smoke alarms:  

 

Provide protection even when electricity fails, provided the batteries are fresh 

and correctly installed. Units are easy to install, and do not require professional installation.

 

AC powered smoke alarms: 

 

Can be interconnected so if one unit senses smoke, all units alarm. They do not operate 

if electricity fails. Units must be installed by a qualified electrician.

 

AC/DC powered smoke alarms (AC with battery back-up): 

 

Can be interconnected so if one unit senses smoke, all 

units alarm. They will operate if electricity fails, provided the batteries are fresh and correctly installed. Units must be 
installed by a qualified electrician.

 

Smoke alarms for the hearing impaired: 

 

 

 

Special purpose smoke alarms should be installed for the hearing 

impaired.

 

 

 

They include a visual alarm and an audible alarm horn, and meet the requirements of the Americans With 

Disabilities Act. These units can be interconnected so if one unit senses smoke, all units alarm. They do not operate if 
electricity fails. Units must be installed by a qualified electrician. 

 

First Alert

 

®

 

 smoke alarm model SA100B is an AC 

powered unit that has an 85 decibel alarm and a 177 candela strobe light, which flashes rapidly when the unit is in alarm. 

All these smoke alarms are designed to provide early warning of fires if located, installed and cared for as described in 
the user’s manual, and if smoke reaches them. If you are unsure which type of smoke alarm to install, refer to 
Chapter 2 of the National Fire Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life 
Safety Code). National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building 
codes may also require specific units in new construction or in different areas of the home.

 

SPECIAL COMPLIANCE CONSIDERATIONS

 

This smoke alarm alone is not a suitable substitute for complete fire detection systems in places housing many 
people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long-term health care facilities, 
nursing homes, day care facilities, or group homes of any kind—even if they were once single-family homes. It is not a 
suitable substitute for complete fire detection systems in warehouses, industrial facilities, commercial buildings, and 
special-purpose non-residential buildings which require special fire detection and alarm systems. Depending on the 
building codes in your area, this smoke alarm may be used to provide additional protection in these facilities.

 

The following information applies to all four types of buildings listed below:  

 

In new construction, most building 

codes require the use of AC or AC/DC powered smoke alarms only. In existing construction, AC, AC/DC, or DC 
powered smoke alarms can be used as specified by local building codes. Refer to NFPA 101 (Life Safety Code) or NFPA 
72 (National Fire Alarm Code), local building codes, or consult your Fire Department for detailed fire protection 
requirements in buildings not defined as “households.” 

 

1. Single-Family Residence: 

 

 Single family home, townhouse. It is recommended smoke alarms be installed on every 

level of the home, in every bedroom, and in each bedroom hallway.

 

2. Multi-Family or Mixed Occupant Residence: 

 

 Apartment building, condominium. This smoke alarm is suitable for 

use in individual apartments or condos, provided a primary fire detection system already exists to meet fire detection 
requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not 
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.

 

3. Institutions: 

 

Hospitals, day care facilities, long-term health care facilities. This smoke alarm is suitable for use in 

individual patient sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection 
requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not 
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.

 

4. Hotels and Motels: 

 

Also boarding houses and dormitories. This smoke alarm is suitable for use inside individual 

sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in 
common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not provide sufficient 
warning to all residents or meet local fire protection ordinances/regulations.

 

LIMITATIONS OF SMOKE ALARMS

 

Smoke alarms have played a key role in reducing deaths resulting from home fires worldwide. However, like any warning 
device, smoke alarms can only work if they are properly located, installed, and maintained, and if smoke reaches them. 
They are not foolproof.

 

Smoke alarms cannot work without power. 

 

 Battery operated units cannot work if the batteries are missing, 

disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units 
cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a 
power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or 
AC power, install both types of units.

 

Smoke alarms cannot detect fires if the smoke does not reach them. 

 

 Smoke from fires in chimneys or walls, on 

roofs, or on the other side of closed doors may not reach the sensing chamber and set off the alarm. That is why one 
unit should be installed inside each bedroom or sleeping area—especially if bedroom or sleeping area doors are closed 
at night—and in the hallway between them.

 

Smoke alarms may not detect fire on another floor or area of the home. 

 

 For example, a stand-alone unit on the 

second floor may not detect smoke from a basement fire until the fire spreads. This may not give you enough time to 
escape safely. That is why recommended minimum protection is at least one unit in every sleeping area, and every 
bedroom on every level of your home. Even with a unit on every floor, stand-alone units may not provide as much 
protection as interconnected units, especially if the fire starts in a remote area. Some safety experts recommend 
installing interconnected AC powered units with battery back-up (see “Other Features Of Smoke Alarms”) or professional 
fire detection systems, so if one unit senses smoke, all units alarm. Interconnected units may provide earlier warning 
than stand-alone units since all units alarm when one detects smoke.

 

Smoke alarms may not be heard. 

 

 Though the alarm horn in this unit meets or exceeds current standards, 

Smoke Alarm With Silence Feature

Cat. SA87B, SA87C

Smoke Alarm With Silence Feature 
and Long-Life Lithium Power

Cat. SA97B, SA97C

Ionization smoke alarms are generally more effective at detecting flaming fires which 
consume combustible materials rapidly and spread quickly. Sources of these fires may 
include paper burning in a wastebasket, or a grease fire in the kitchen.

Photoelectric smoke alarms are generally more effective at detecting smoldering fires 
which smolder for hours before bursting into flame. Sources of these fires may include 
cigarettes burning in couches or bedding.

For maximum protection, use both types of smoke alarms on each level of your home.

User’s Manual

M06-2008-005 8/99

Model

SA87B
SA97B

IMPORTANT! PLEASE READ CAREFULLY AND SAVE.

This user’s manual contains important information about your smoke alarm’s operation. If you are installing 
this smoke alarm for use by others, you must leave this manual—or a copy of it—with the end user.