First Alert MODEL FCD3N User Manual Download Page 19

18

CHAPTER 7:

 Troubleshooting Guide

Problem...

This means...

You should...

The BATTERY Light turns 
YELLOW. It flashes and the 
horn “chirps” twice a minute.

Low battery warning.

Install a new 9V alkaline or lithium battery*.

During testing, when you 
press and hold the Test/
Silence button, the BATTERY 
Light turns YELLOW.

Low battery

Install a new 9V alkaline or lithium battery*.

Horn chirps and yellow 
service light blinks three 
times every 30 seconds.

Unit needs to be 
replaced.

Units under warranty should be returned to 
manufacturer for replacement. See “Limited 
Warranty” for details. 

CO Alarm goes back into 
alarm 4 minutes after you 
press the Test/Silence 
button.

CO levels indicate a 
potentially dangerous 
situation.

IF YOU ARE FEELING SYMPTOMS OF CO 
POISONING, EVACUATE your home and call 
911 or the Fire Department. If not, press the 
Test/Silence button again and keep 
ventilating your home

.

CO Alarm alarms frequently 
even though no high levels of 
CO are revealed in an 
investigation.

The CO Alarm may be 
improperly located. 
Refer to “Where to Install 
Your CO Alarm.”

Relocate your alarm. If frequent alarms 
continue, have home rechecked for potential 
CO problems. You may be experiencing an 
intermittent CO problem.

*For a list of acceptable replacement batteries, see “Regular Maintenance.”

If you have any questions that cannot be answered by reading this manual, call our Consumer Affairs 
Department at 1-800-323-9005, 7:30 a.m. - 5:00 p.m. (CT).

M06_1042_001.E  Page 18  Wednesday, July 12, 2000  9:26 AM

Summary of Contents for MODEL FCD3N

Page 1: ...MODEL FCD3N User s Manual Battery Operated Carbon Monoxide Alarm M06 1042 001 7 00 M06_1042_001 E Page 1 Wednesday July 12 2000 9 26 AM...

Page 2: ...ESTING AND MAINTENANCE 12 CHAPTER 5 WHAT YOU NEED TO KNOW ABOUT CO 14 What is CO 14 Symptoms of CO Poisoning 14 Potential Sources Of CO In The Home 15 How Can I Protect My Family 16 CHAPTER 6 UNDERWRI...

Page 3: ...do so can result in injury or death WARNING This CO Alarm does not operate without a working battery Removing the battery or failure to replace it at the end of its service life removes your protectio...

Page 4: ...ures a permanently installed sensor three colored indicator lights and an 85 dB alarm horn It also has a silence feature to temporarily quiet the alarm horn The Cover of Your CO Alarm 1 Test Silence B...

Page 5: ...press the Test Silence button all three lights will flash briefly but the horn may stay silent If the battery is WEAK the BATTERY light flashes YELLOW IMPORTANT Replace a weak battery immediately CO A...

Page 6: ...ht flashes rapidly This CO alarm is designed to sound for up to 12 hours in alarm conditions provided the battery is fresh and installed correctly Warranty 5 year limited warranty Standards Underwrite...

Page 7: ...t 6 meters away from the furnace or fuel burning heat source In a Multi level Home Install at least one CO Alarm near or within each separate sleeping area For added protection install at least one CO...

Page 8: ...air returns or open windows Blowing air may prevent CO from reaching the sensors In direct sunlight WARNING This CO Alarm is designed for use inside a single family home or apartment It is not meant...

Page 9: ...liance technician is defined as a person firm corporation or company that either in person or through a representative is engaged in and responsible for the installation testing servicing or replaceme...

Page 10: ...marks you made for the mounting holes 4 Insert the plastic screw anchors into the mounting holes until they are flush with the wall If necessary tap them gently with a hammer 5 Line up the mounting br...

Page 11: ...l burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have the equipment serviced immediately Note any combustion equi...

Page 12: ...tern 4 beeps a pause 4 beeps etc Press and hold the Test Silence button until the horn is silent The initial Silence cycle will last approximately 4 minutes NOTE After initial 4 minute Silence cycle t...

Page 13: ...y is low or weak the BATTERY light will flash YELLOW Even if the horn sounds you should replace a low or weak battery immediately for optimum performance If the alarm does not test properly 1 Make sur...

Page 14: ...atteries are acceptable as replacements Duracell MN1604 You can also use an Ultralife 9 volt lithium battery U9VL for longer service life between battery changes These replacement batteries are common...

Page 15: ...bbing headache drowsiness confusion fast heart rate Extreme Exposure Convulsions unconsciousness heart and lung failure Exposure to Carbon Monoxide can cause brain damage death CAUTION Some individual...

Page 16: ...outdoor conditions such as Wind direction and or velocity including high gusty winds Heavy air in the vent pipes cold humid air with extended periods between cycles Negative pressure differential res...

Page 17: ...ing appliances Check appli ances for excessive rust and scaling Also check the flame on the burner and pilot lights The flame should be blue A yellow flame means fuel is not being burned completely an...

Page 18: ...age healthy adults after 35 minutes but can cause death after 2 hours IMPORTANT This CO Alarm measures exposure to CO over time It alarms if CO levels are extremely high in a short period of time or i...

Page 19: ...lence button CO levels indicate a potentially dangerous situation IF YOU ARE FEELING SYMPTOMS OF CO POISONING EVACUATE your home and call 911 or the Fire Department If not press the Test Silence butto...

Page 20: ...ally true if the door is closed or only partly open Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors Noise from traffic stereo radio televisio...

Page 21: ...ts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current or use contrary to the operating instructions disassembly repair or alteratio...

Page 22: ...21 NOTES M06_1042_001 E Page 21 Wednesday July 12 2000 9 26 AM...

Page 23: ...22 NOTES M06_1042_001 E Page 22 Wednesday July 12 2000 9 26 AM...

Reviews: