CHAPTER 6:

 Underwriters Laboratories Inc. UL2034

What Levels of CO Cause an Alarm?

Underwriters Laboratories Inc. UL2034 defines 
3 specific alarm points by which all residential 
CO Alarms must alarm. They are measured in 
parts per million (ppm) of CO over time (in 
minutes). 

UL2034 Required Alarm Points:

If the alarm is exposed to 400 ppm
of CO, IT MUST ALARM BETWEEN 
4 and 15 MINUTES

If the alarm is exposed to 150 ppm 
of CO, IT MUST ALARM BETWEEN 
10 and 50 MINUTES.

If the alarm is exposed to 70 ppm 
of CO, IT MUST ALARM BETWEEN 
60 and 240 MINUTES.

IMPORTANT

!

CO Alarms are designed to alarm before there 
is an immediate life threat. Since you cannot 
see or smell CO, never assume it’s not present.

An exposure to 100 ppm of CO for 20 
minutes may not affect average, healthy 
adults, but after 4 hours the same level 
may cause headaches. 

An exposure to 400 ppm of CO may 
cause headaches in average, healthy 
adults after 35 minutes, but can cause 
death after 2 hours.

IMPORTANT

!

This CO Alarm measures exposure to CO over 
time. It alarms if CO levels are extremely high in 
a short period of time, or if CO levels reach a 
certain minimum over a long period of time. The 
CO Alarm generally sounds an alarm before the 
onset of symptoms in average, healthy adults.

Why is this important? Because you need to be 
warned of a potential CO problem while you 
can still react in time. In many reported cases of 
CO exposure, victims may be aware that they 
are not feeling well, but become disoriented 
and can no longer react well enough to exit the 
building or get help. Also, young children and 
pets may be the first affected. The average 
healthy adult might not feel any symptoms 
when the CO Alarm alarms. However, people 
with cardiac or respiratory problems, infants, 
unborn babies, pregnant mothers, or elderly 
people can be more quickly and severely 
affected by CO. If you experience even mild 
symptoms of CO poisoning, consult your 
doctor immediately!

M06_1039_003.E  Page 15  Wednesday, July 12, 2000  9:40 AM

Summary of Contents for FCD2N

Page 1: ...MODEL FCD2N User s Manual 120V Plug In Carbon Monoxide Alarm With Silence Feature M06 1039 003 7 00 120V AC 60 Hz 085A Standby 087A Alarm M06_1039_003 E Page 1 Wednesday July 12 2000 9 40 AM...

Page 2: ...NG AND MAINTENANCE 11 CHAPTER 5 WHAT YOU NEED TO KNOW ABOUT CO 12 What is CO 12 Symptoms of CO Poisoning 12 Potential Sources Of CO In The Home 13 How Can I Protect My Family 14 CHAPTER 6 UNDERWRITERS...

Page 3: ...after any alarm Failure to do so can result in injury or death WARNING This CO Alarm can not operate without continuous electricity It does not operate during a power failure WARNING NEVER ignore your...

Page 4: ...it has been exposed to over time The unit goes into alarm mode when it has been exposed to a critical level of CO measured in parts per million or ppm within a specified time measured in minutes This...

Page 5: ...en light ON Yellow red lights OFF Horn silent During Alarm Malfunction Green light ON Yellow light ON Red light FLASHES Horn chirps about twice a minute During Normal Test All three lights flash brief...

Page 6: ...ensions 5 83 x 3 32 x 1 6 Approx Supply Voltage 120V AC 60Hz 085A Standby 087A Alarm During Alarm CO Alarm horn sounds while the red light flashes rapidly Warranty 5 year limited warranty Standards Un...

Page 7: ...g heat source In a Multi level Home Install at least one CO Alarm near or within each separate sleeping area For added protection install at least one CO Alarm on each level of the home If you have a...

Page 8: ...wing air may prevent CO or smoke from reaching the sensors In direct sunlight In outlets covered by curtains or other obstruction WARNING This CO Alarm is designed for use inside a single family home...

Page 9: ...sounds four loud beeps pause 4 beeps The sequence should last 5 6 seconds During testing the green yellow and red lights flash This is normal 4 While testing the unit have a family member check that...

Page 10: ...burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have the equipment serviced immediately Note any combustion equip...

Page 11: ...ps etc Press and hold the Test Silence button until the horn is silent The initial Silence cycle will last approximately 4 minutes NOTE After initial 4 minute Silence cycle the CO Alarm re evaluates p...

Page 12: ...ENANCE To keep the CO Alarm in good working order Test it every week using the Test Silence button Vacuum the CO Alarm cover at least once a month using the soft brush attachment Never use water clean...

Page 13: ...bbing headache drowsiness confusion fast heart rate Extreme Exposure Convulsions unconsciousness heart and lung failure Exposure to Carbon Monoxide can cause brain damage death CAUTION Some individual...

Page 14: ...outdoor conditions such as Wind direction and or velocity including high gusty winds Heavy air in the vent pipes cold humid air with extended periods between cycles Negative pressure differential res...

Page 15: ...ing appliances Check appli ances for excessive rust and scaling Also check the flame on the burner and pilot lights The flame should be blue A yellow flame means fuel is not being burned completely an...

Page 16: ...e healthy adults after 35 minutes but can cause death after 2 hours IMPORTANT This CO Alarm measures exposure to CO over time It alarms if CO levels are extremely high in a short period of time or if...

Page 17: ...Alarm goes back into alarm 4 minutes after you press the Test Silence button CO levels are still potentially dangerous Refer to Chapter 3 If Your CO Alarm Sounds for details on how to respond to an al...

Page 18: ...olic beverages This is especially true if the door is closed or only partly open Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors Noise from t...

Page 19: ...ts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current or use contrary to the operating instructions disassembly repair or alteratio...

Page 20: ...19 NOTES M06_1039_003 E Page 19 Wednesday July 12 2000 9 40 AM...

Page 21: ...20 NOTES M06_1039_003 E Page 20 Wednesday July 12 2000 9 40 AM...

Page 22: ...21 NOTES M06_1039_003 E Page 21 Wednesday July 12 2000 9 40 AM...

Page 23: ...22 NOTES M06_1039_003 E Page 22 Wednesday July 12 2000 9 40 AM...

Reviews: