background image

¬.20Al

K3590-OM  4/01

SETTING THE KEYPAD ADDRESS

The keypad can be set for an address of 1-8. The keypad's
default address is 8.

To change the keypad's address, do the following:

1.

Enter Address mode: Power up the keypad.  Within 60
seconds of power-up, press and hold down the Stay and
Code keys at the same time for 3 seconds.  (If unable to
enter Address mode, power up and try again.)

The current keypad address will be displayed.  If 10
seconds have passed with no key entry, the keypad
automatically exits Address mode.  If this happens, you
must power down, power up and enter Address mode
again.

2. If the panel does not send a valid command to the

keypad, the display will remain blank.

3. Exit Address mode:

Press [

] to save the displayed address and exit Address

mode.

VIEWING THE KEYPAD ADDRESS

Press and hold down the STAY and CODE  keys  at  the
same time for about 3 seconds.  The current address is
displayed.  No key entry is allowed.  Press any key to exit or
wait 10 seconds to exit viewing mode.

TURNING THE SOUNDER ON/OFF

FA260KP-OM:

Press the BYPASS and CODE keys at the same time
and hold down for two seconds until you hear a beep.
Press any key to toggle the sounder on or off.
0 = Sounder off
1 = Sounder on.

FA560KP-OM:
There are four modes available in the Sounder Menu.  They
are as follows:

 

Off – No Sounds at all

 

Key – Only Key Clicks

 

Fire – Only Fire Sounder (temporal sounder – not
supported by all panels)

 

On – Normal Sounder Keys (all sounds on)

USING THE SOUNDER MENU (FA560KP-OM only)

1.

 

Press the BYPASS and CODE keys at the same time
and hold down for two seconds. This accesses the
Sounder Menu.

2.

 

Press the [1] key to toggle through the four modes listed
above (stop at desired mode).

3.

 

Press the [2] key to toggle through the sounder volume
choices (high or low appears on the display).

4.

 

Press the [3] key to adjust the sound of the key acknow-
ledge (Ack H or L appears on the display).

5.

 

Press the [

] key to exit the Sounder Menu.

SPECIFICATIONS

Physical:
FA260KP-OM:  6-5/8'H x 4-7/8"W x 1-5/16"D
FA560KP-OM:  7-5/16'H x 5-3/8"W x 1-3/8"D

Displays:
FA260KP-OM: Fixed-Word LCD (backlit)
FA560KP-OM: 2 x 16 alphnumeric LCD (backlit)

Sounder:
FA260KP-OM: Speaker
FA560KP-OM: Speaker

Current:
FA260KP-OM: 150mA (backlight and sounder on).

75mA standby mode (backlight on)

FA560KP-OM: 150mA (backlight and sounder on).

80mA standby mode (backlight on)

REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR

WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

175 Eileen Way, Syosset, New York 11791

C

opyright 

 2001

Reviews: