PROGRAMMING FORM
Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Field Function
Data Entries
Programmable Values
SYSTEM SETUP (
✱
20–
✱
29)
✱
20
INSTALLER CODE
| | |
4 digits, 0–9
NOTE:
Installer code is automatically disabled 4 hours
after power-up.
✱
21
QUICK ARM ENABLE
[1,1]
Part. 1 Part.2
0 = no; 1 = yes
✱
22
RF JAM OPTION
[1]
0 = no RF Jam detection; 1 = send RF Jam report
UL: must be 1 if wireless devices are used
✱
23
QUICK (FORCED) BYPASS
[0,0]
Part. 1 Part. 2
0 = no quick bypass UL: must be “0”
1 = allow quick bypass (code + [6] + [#] )
✱
24
RF HOUSE ID CODE
| | |
Part. 1 Part. 2 Common
00 = disable all wireless keypad usage
01–31 = using 5827, 5827BD or 5804BD keypad
[00,00,00]
✱
26
CHIME BY ZONE
[0]
0 = no; 1 = yes (select zones to chime on zone list 3,
using *81 Menu mode)
✱
27
POWERLINE CARRIER DEVICE (X–10)
HOUSE CODE
[0]
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G,
7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N,
#14 = O, #15 = P UL: not for fire or UL installations
✱
28
ACCESS CODE FOR
PHONE
MODULE
| [00]
(Partition 1 only)
00 = disable; 1st digit: enter 1–9; 2nd digit: enter # + 11
for "
✱
", or # + 12 for "#".
UL: must be “00” for UL Commercial Burg. installations
✱
29
LONG RANGE RADIO OUTPUT
[0]
0 = disable; 1 = enable
ZONE SOUNDS AND TIMING (
✱
31 –
✱
39)
✱
31
SINGLE ALARM SOUNDING per ZONE
[1]
0 = no; 1 = yes
✱
32
FIRE ALARM SOUNDER TIMEOUT
[0]
0 = sounder stops at timeout;
1 = no sounder timeout UL: must be “1” for fire install.
✱
33
ALARM SOUNDER (BELL) TIMEOUT
[1]
0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min; 4 = 16 min;
UL: For residential fire alarm installation, must be set for a
minimum of 4 min (option 1); for UL Commercial Burglary
installations, must be minimum 16 min (option 4)
✱
34
EXIT
DELAY
| | [60, 60]
Part. 1 Part. 2
Common zones use same
delay as partition 1
.
00 - 96 = 0 - 96 secs; 97 = 120 secs;
98 = 180 secs;
99 = 240 secs
SIA Installations: minimum exit delay is 45 seconds
UL: see inst. instr. for requirements.
✱
35
ENTRY DELAY #1 (zone type 01)
| | [30, 30]
Part. 1 Part. 2
Common zones use same
delay as partition 1
.
00 - 96 = 0 - 96 seconds
97 = 120 seconds
SIA Installations:
98 = 180 seconds
minimum entry delay is
99 = 240 seconds
30 seconds
For UL Residential Burglary Alarm installations, must be set
for a maximum of 30 seconds; entry delay plus dial delay
should not exceed 1 min. For UL Commercial Burglar
Alarm, total entry delay may not exceed 45 seconds.
✱
36
ENTRY DELAY #2 (zone type 02)
| | [30, 30]
Part. 1 Part. 2
See *35 Entry Delay 1 above for entries.
Common zones use same delay as partition 1.
∗∗∗∗
37
AUDIBLE EXIT WARNING
[1,1]
Part. 1 Part. 2
0 = no; 1 = yes
SIA Installations: must be enabled (enter 1)
✱
38
CONFIRMATION
OF
ARMING/DISARMING DING
[0,0]
Part. 1 Part. 2
0 = no; 1 = yes (wired keypads and RF)
2 = yes, RF only
UL: must be “1” for UL Commercial Burglar Alarm inst.
✱
39
POWER UP IN PREVIOUS STATE
[1]
0 = always power up disarmed
1 = power up in previous state UL: must be “1”
SIA Installations: must be “1”
DIALER PROGRAMMING (
✱
40 –
✱
42)
Enter the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '
✱
'; #+12 for '#'; #+13 for a 2-second pause. If fewer than the
maximum digits entered, exit the field by pressing [
✶
]. The next field number is displayed.
✱
40
PABX ACCESS CODE or
CALL WAITING DISABLE
| | | | | Enter up to 6 digits. To clear entries, press
✱
40
✱
. If call
waiting used, enter “
∗
(#+11) 70” plus “# + 13” (pause). See Inst. Instr. for notes on
using the Call Waiting Disable feature.
✱
41
PRIMARY PHONE No.
| | | | | | | | | | | | | | | | | | |
✱
42
SECOND PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. To clear entries, press
✱
41
✱
or
✱
42
✱
respectively.