INTRODUCTION

Thank you for choosing BRK Brands, Inc. for your Smoke Alarm needs. You have pur-

chased a state-of-the-art Smoke Alarm designed to provide you with early warning of a fire.  

Key features include:
Smart Technology

 designed to help reduce unwanted or nuisance alarms.

Single Button Test/Silence

 eliminates confusion. Depending on what mode the alarm is  

in, pushing the button provides different functions such as testing the alarm, silencing the 

alarm, re-testing the alarm when in silence and clearing the Latching feature.

Latching Alarm Indicator

 easily identifies initiating alarm even after the alarm condition 

has subsided.

Perfect Mount System

 includes a gasketless base for easy installation and a new mounting 

bracket that keeps the alarm secure over a wide rotation range to allow for perfect  

alignment.

Dust Cover

 is included to keep the alarm clean during construction.

Easy Installation/Maintenance

 features include a large opening in the mounting bracket for 

easy access to wiring. A battery pull tab keeps the battery fresh until the home is occupied. 

A Side Load Battery Drawer allows for easy battery replacement without removing the alarm 

from the ceiling or wall.

Improved UV Resistance

 keeps the alarm from discoloring over time.

© 2015 BRK Brands, Inc.  All rights reserved.  Distributed by BRK Brands, Inc. 

BRK

®

 is a registered trademark of BRK Brands, Inc. 

First Alert

®

 is a registered trademark of the First Alert Trust. 

3901 Liberty Street Road, Aurora, IL 60504-8122 
Consumer Affairs: (800) 323-9005 
www.brkelectronics.com   •   www.firstalert.com

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking materials properly. 

Never smoke in bed. 2) Keep matches or lighters away from children; 3) Store flammable 

materials in proper containers; 4) Keep electrical appliances in good condition and don’t 

overload electrical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys grease- 

and debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep portable 

heaters and open flames, like candles, away from flammable materials; 8) Don’t let rubbish 

accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they are not 

working properly. Smoke Alarms that do not work cannot alert you to a fire. Keep at least 

one working fire extinguisher on every floor, and an additional one in the kitchen. Have fire 

escape ladders or other reliable means of escape from an upper floor in case stairs are 

blocked.

BEFORE YOU INSTALL THIS SMOKE ALARM

Important!

 Read “Recommended Locations for Smoke Alarms” and “Locations to Avoid  

for Smoke Alarms” before beginning. This unit monitors the air, and when smoke reaches  

its sensing chamber, it alarms. It can give you more time to escape before fire spreads.  

This unit can ONLY give an early warning of developing fires if it is installed, maintained and 

located where smoke can reach it, and where all residents can hear it, as described in this 

manual. This unit will not sense gas, heat, or flame. It cannot prevent or extinguish fires.

Understand The Different Type of Smoke Alarms

Battery powered or electrical? Different Smoke Alarms provide different types of  

protection. See “About Smoke Alarms” for details. 

Know Where To Install Your Smoke Alarms

Fire Safety Professionals recommend at least one Smoke Alarm on every level of your 

home, in every bedroom, and in every bedroom hallway or separate sleeping area. See 

“Recommended Locations For Smoke Alarms” and “Locations To Avoid For Smoke 

Alarms” for details.

Know What Smoke Alarms Can and Can’t Do

A Smoke Alarm can help alert you to fire, giving you precious time to escape. It can 

only sound an alarm once smoke reaches the sensor. See “Limitations of Smoke 

Alarms” for details.

Check Your Local Building Codes

This Smoke Alarm is designed to be used in a typical single-family home. It alone will not 

meet requirements for boarding houses, apartment buildings, hotels or motels. See “Special 

Compliance Considerations” for details.

1

All First Alert

®

 and BRK

®

 Smoke Alarms conform to regulatory requirements,  

including UL217 and are designed to detect particles of combustion. Smoke parti-

cles of varying number and size are produced in all fires.

Ionization technology is generally more sensitive than photoelectric technology  

at detecting small particles, which tend to be produced in greater amounts by 

flaming fires, which consume combustible materials rapidly and spread quickly. 

Sources of these fires may include paper burning in a wastebasket, or a grease 

fire in the kitchen.

Photoelectric technology is generally more sensitive than ionization technology at 

detecting large particles, which tend to be produced in greater amounts by smol-

dering fires, which may smolder for hours before bursting into flame. Sources of 

these fires may include cigarettes burning in couches or bedding.

For maximum protection, use both types of Smoke Alarms on each level and in every 

bedroom of your home.

 

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Smoke 

Alarm is installed before removing it from the mounting bracket. Failure to turn off 

the power first may result in serious electrical shock, injury or death.

 

•    This unit will not alert hearing impaired residents. It is recommended that 

you install special units which use devices like flashing strobe lights to alert 

hearing impaired residents.

 

•    Installation of this unit must conform to the electrical codes in your area; 

Articles 210 and 300.3 (B) of NFPA 70 (NEC), NFPA 72, NFPA 101; ICC; SBC 

(SBCCI); UBC (ICBO); NBC (BOCA); OTFDC (CABO), and any other local or 

building codes that may apply. Wiring and installation must be performed by 

a licensed electrician. Failure to follow these guidelines may result in injury 

or property damage.

 

•    This unit must be powered by a 24-hour, 120V AC pure sine wave 60 Hz  

circuit. Be sure the circuit cannot be turned off by a switch, dimmer, or 

ground fault circuit interrupter. Failure to connect this unit to a 24-hour  

circuit may prevent it from providing constant protection. Unit may be  

connected to an arc fault circuit interrupter.

 

•    This Smoke Alarm must have AC or battery power to operate. If the AC 

power fails, battery back-up will allow the alarm to sound for at least 4  

minutes. If AC power fails and the battery is weak, protection should last for 

up to 7 days. If AC power fails and the battery is dead or missing, the alarm 

cannot operate.

 

•    Never disconnect the power from an AC powered unit to stop an unwanted 

alarm. Doing so will disable the unit and remove your protection. In the case 

of a true unwanted alarm open a window or fan the smoke away from the 

unit. The alarm will reset automatically when it returns to normal operation. 

Never remove the batteries from a battery operated unit to stop an unwanted 

alarm (caused by cooking smoke, etc.). Instead open a window or fan the 

smoke away from the unit. The alarm will reset automatically.

 

•    Connect this unit ONLY to other compatible units. See “How To Install This 

Smoke Alarm” for details. Do not connect it to any other type of alarm or  

auxiliary device. Connecting anything else to this unit may damage it or  

prevent it from operating properly.

 

•    The battery compartment resists closing unless a battery is installed. This 

warns you the unit will not operate under DC power without a battery.

 

•    Do not paint over the unit. Paint may clog the openings to the sensing  

chamber and prevent the unit from operating properly.

IMPORTANT! PLEASE READ CAREFULLY AND SAVE

This user’s manual contains important information about your Smoke Alarm’s opera-

tion. If you are installing the Smoke Alarm for use by others, you must leave this man-

ual — or a copy of it — with the end user.

The Mounting Bracket:

  

To remove the mounting bracket from the Smoke Alarm base, 

hold the Smoke Alarm base firmly and twist the mounting  

bracket counterclockwise. The mounting bracket installs onto  

the junction box. It has a variety of screw slots to fit most boxes.

The Power Connector:  

The power connector plugs into a power input block on the  

Smoke Alarm. It supplies the unit with AC power.

• The black wire is “hot.”

• The white wire is neutral.

•  The orange wire is used for interconnect.

If you need to remove the power connector, insert a flat screwdriver 

blade between the power connector and the security tab inside the  

power input block. Gently pry back the tab and pull the connector free.

1

2

3

5

6

4

2

3

9

7

8

The Parts of This Unit

Mounting Bracket

Mounting Slots

Locking Pins (break out of bracket)

Hot (Black) AC Wire

Neutral (White) AC Wire

Interconnect (Orange) Wire

Latch to Open Battery Compartment

Swing-Out Battery Compartment

Quick-Connect Power Connector

The basic installation of this Smoke Alarm is similar whether you want to install one  

Smoke Alarm, or interconnect more than one Smoke Alarm. If you are interconnecting 

more than one Smoke Alarm, you MUST read “Special Requirements For Interconnected 

Smoke Alarms” below before you begin installation.

 

ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this  

unit at the circuit breaker or fuse box before beginning installation. Failure to turn off 

the power before installation may result in serious electrical shock, injury or death.

1.  Using wire nuts, connect the power connector to the household wiring.

 

Improper wiring of the power connector or the wiring leading to the power connec-

tor will cause damage to the Alarm and may lead to a non-functioning Alarm.

2.  Remove the mounting bracket from the base, and attach it to the junction box.

3.  Plug the power connector into the back of the Smoke Alarm.

4.  Position the base of the Smoke Alarm over the mounting bracket and turn. The 

Alarm will remain secure over a wide rotation range to allow for perfect alignment. 

When wall mounting, this will allow fine-tuning on the positioning to compensate  

for misaligned wall studs and to keep the wording level. The Alarm can be positioned 

over the bracket every 120°. Rotate the Alarm until aligned properly.

5.  Check all connections.

 

ELECTRICAL SHOCK HAZARD. Do not restore power until all Smoke Alarms are  

completely installed. Restoring power before installation is complete may result in  

serious electrical shock, injury or death.

6.  Make sure the Smoke Alarm is receiving AC power. Under normal operation, the 

Green power indicator light will shine continuously.

7.  If the Green power indicator light does not light, 

TURN OFF POWER TO THE  

JUNCTION BOX

 and recheck all connections. If all connections are correct and  

the Green power indicator still does not light when you restore the power, the unit 

should be replaced immediately.

8. 

Single Station Alarms:

 Test each Smoke Alarm. Press and hold the Test/Silence  

button until the unit alarms.  

Interconnected Alarms:

 Press and hold the Test/Silence button until the unit 

alarms. All interconnected Alarms should sound. The other Alarms sounding only 

tests the interconnect signal between Alarms. It does not test each Alarm’s opera-

tion. 

You must test each Alarm individually to check if the Alarm is functioning 

properly.

 

If any unit in the series does not alarm, 

TURN OFF POWER

 and recheck connections.  

If it does not alarm when you restore power, replace it immediately.

SPECIAL REQUIREMENTS FOR INTERCONNECTED SMOKE ALARMS

•   Failure to meet any of the above requirements could damage the units and 

cause them to malfunction, removing your protection.

•   AC and AC/DC Smoke Alarms can be interconnected. Under AC power, all 

units will alarm when one senses smoke. When power is interrupted, only  

the AC/DC units in the series will continue to send and receive signals.  

AC powered Smoke Alarms will not operate.

Interconnected units can provide earlier warning of fire than stand-alone units, especially 

if a fire starts in a remote area of the dwelling. If any unit in the series senses smoke, all 

units will alarm. To determine which Smoke Alarm initiated an alarm, see table:

During an Alarm:

On Initiating Alarm(s)  

Red LED(s) flashes (flash) rapidly

On All Other Alarms  

Red LED is Off

After an Alarm (Latching):

On Initiating Alarm(s)  

Green LED(s) On for 2 seconds/Off for 2 seconds

On All Other Alarms  

Green LED(s) On, Red LED(s) is Off

Compatible Interconnected Units

 

Interconnect units within a single family residence only. Otherwise all households will  

experience unwanted alarms when you test any unit in the series. Interconnected units 

will only work if they are wired to compatible units and all requirements are met. This unit 

is designed to be compatible with:  

First Alert

®

 Smoke Alarm Models

 SA4120, SA4121B, SA100B, SA520 and 

BRK

®

 Smoke 

Alarm Models

 9120B, SC6120B, SC9120B, 7010B, SC7010B, SC7010BV, 100S, 4120, 

4120B, 4120SB; 

BRK

®

 CO Alarm Models

 CO5120BN, CO5120PDBN; 

BRK

®

 Heat 

Alarm Models

 HD6135F and HD6135FB; 

BRK

®

 Auxiliary Devices Models 

RM3 and 

RM4 (Relay Modules), SL177 (Strobe Light).  

See www.brkelectronics.com for most current interconnect list.

Interconnected units must meet ALL of the following requirements:

•  A maximum of 18 compatible units may be interconnected  

(Maximum of 12 Smoke Alarms).

•  The same fuse or circuit breaker must power all interconnected units.
•  The total length of wire interconnecting the units should be less than 1000 feet  

(300 meters). This type of wire is commonly available at Hardware and Electrical 

Supply stores.

•  All wiring must conform to all local electrical codes and NFPA 70 (NEC). Refer 

to NFPA 72, NFPA 101, and/or your local building code for further connection 

requirements.

HOW TO INSTALL THIS SMOKE ALARM

THE PARTS OF THIS SMOKE ALARM

This Smoke Alarm is designed to be mounted on any standard wiring junction box to a 4-inch (10 cm) size, on either the ceiling or wall. Read “Recommended Locations For Smoke Alarms” and 

“Locations to Avoid For Smoke Alarms” before you begin installation. 

Tools you will need:  • Needle-nose pliers or utility knife

  • 

Standard Flathead screwdriver.

STAND-ALONE ALARM ONLY:

• 

Connect the white wire on the power connector to the neutral wire in the junction 

box.

• 

Connect the black wire on the power connector to the hot wire in the junction 

box.

• 

Tuck the orange wire inside the junction box. It is used for interconnect only.

INTERCONNECTED UNITS ONLY:
Strip off about 1/2” (12 mm) of the plastic coating on the orange wire on the 

power connector.

• 

Connect the white wire on the power connector to the neutral wire in the junction 

box.

• 

Connect the black wire on the power connector to the hot wire in the junction box.

• 

Connect the orange wire on the power connector to the interconnect wire in the 

junction box. Repeat for each unit you are interconnecting. Never connect the hot 

or neutral wires in the junction box to the orange interconnect wire. Never cross hot 

and neutral wires between Alarms.

STAND-ALONE ALARM ONLY:

• 

If you are only installing one Smoke Alarm, restore power to the junction box.

INTERCONNECTED UNITS ONLY:
• 

If you are interconnecting multiple Smoke Alarms, repeat steps 1-5 for each 

Smoke Alarm in the series. When you are finished, restore power to the  

junction box.

8

4

3
1

5

4

3
1

5

2

A

B

}

}

A.  Unswitched 120VAC  

60 Hz source

B.  To additional units; Maximum = 18 total 

(Maximum 12 Smoke Alarms)

1. Smoke Alarm
2. Ceiling or Wall
3.  Power Connector

4. Wire Nut
5. Junction Box
6.  Neutral Wire (Wht) 

7.  Interconnect Wire 

(Orange)

8.  Hot Wire (Blk) 

FOLLOW THESE INSTALLATION STEPS

 

   Make sure the Alarm is not receiving excessively noisy power. Examples of noisy power could be major appliances on the same circuit, power from a generator or solar power, 

light dimmer on the same circuit or mounted near fluorescent lighting. Excessively noisy power may cause damage to your Alarm.

9.  For new construction, place supplied dust cover over Alarm to prevent damage from 

dust and construction debris. When construction is complete, remove cover.

 

Smoke will not be able to reach smoke sensor while cover is in place. Cover must 

be removed!

2

3

4

OPTIONAL LOCKING FEATURES

The optional locking features are designed to discourage unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households where  

unauthorized battery or alarm removal is not a concern.

These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting bracket.  

You can choose to use either feature independently, or use them both.

Tools you will need:

  • Needle-nose pliers or utility knife  • Standard Flathead screwdriver.

Both locking features use locking pins, which are molded into the mounting bracket. Using needle nose pliers or a utility knife, remove one or both pins from the 

mounting bracket, depending on how many locking features you want to use.

 

To permanently remove either lock insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.

Locking Pin

TO LOCK THE BATTERY COMPARTMENT

Do not lock the battery compartment until you have activated the battery and  

tested the battery back-up.

1.  Activate the battery back-up by removing the 

“Pull to Activate Battery Back-Up” tab.

2.  Push and hold test button until the alarm 

sounds: 3 beeps, pause, 3 beeps, pause.

 

If the unit does not alarm during testing, DO 

NOT lock the battery compartment! Install a  

new battery and test again. If the Smoke Alarm 

still does not alarm, replace it immediately.

3.  Using needle-nose pliers or a utility knife, 

detach one locking pin from the mounting 

bracket.

TO UNLOCK THE BATTERY COMPARTMENT

 

Once the Smoke Alarm is installed, you must disconnect it from the AC power before  

unlocking the battery compartment.

 

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Smoke 

Alarm is installed before removing it from the mounting bracket. Failure to turn off the 

power first may result in serious electrical shock, injury or death.

 

Always discharge the branch circuit before servicing an AC or AC/DC Smoke Alarm.  

First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery 

from Smoke Alarms with battery back-up. Finally, press and hold the test button for 5-10 

seconds to discharge the branch circuit.

1.  Remove the Smoke Alarm from the mounting bracket. If the unit is locked to the  

bracket, see the section “To Unlock the Mounting Bracket.”

2.  Disconnect the power connector by gently prying it away from the back of the Smoke 

Alarm.

3.  Insert a flathead screwdriver under the head of  

the locking pin, and gently pry it out of the battery 

compartment lock. (If you plan to relock the battery 

compartment, save the locking pin.)

4.  To relock the battery compartment, close the battery 

door and reinsert locking pin in lock.

5.  Reconnect the power connector to the back of the 

Smoke Alarm, reattach the Smoke Alarm to the  

mounting bracket, and restore the power.

 

When replacing the battery, always test the Smoke Alarm before relocking the battery  

compartment.

TO UNLOCK THE MOUNTING BRACKET

 

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Smoke 

Alarm is installed before removing it from the mounting bracket. Failure to turn off 

the power first may result in serious electrical shock, injury or death.

 

Always discharge the branch circuit before servicing an AC or AC/DC Smoke Alarm. 

First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery 

from Smoke Alarms with battery back-up. Finally, press and hold the test button for  

5-10 seconds to discharge the branch circuit.

1.  Insert a flathead screwdriver between the mounting bracket pin and the mounting 

bracket.

2.  Pry the Smoke Alarm away from the bracket by turning both the screwdriver and the 

Smoke Alarm counterclockwise (left) at the same time.

TO LOCK THE MOUNTING BRACKET

1.  Using needle-nose pliers or utility knife, 

detach one locking pin from mounting 

bracket.

2.  Insert the locking pin into the  

lock located on the base as shown  

in the diagram.

3.  When you attach the Smoke 

Alarm to the mounting 

bracket, the locking pin’s 

head will fit into a notch on 

the bracket.

Locking Features (Continued)

4.  Push the locking pin through the black  

dot on the label on the back of the Smoke 

Alarm.

WEEKLY TESTING

 

NEVER use an open flame of any kind to test this unit. You might accidentally dam-

age or set fire to the unit or to your home. The built-in test switch accurately tests the 

unit’s operation as required by Underwriters Laboratories, Inc. (UL).

 

DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range 

may be harmful to your hearing. When testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is working properly. Using 

the test button is the recommended way to test this Smoke Alarm.

 Press and hold the 

test button on the cover of the unit until the alarm sounds (the unit may continue to alarm 

for a few seconds after you release the button). If it does not alarm, make sure the unit is 

receiving power and test it again. If it still does not alarm, replace it immediately. 

During 

testing, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.

When testing a series of interconnected units you must test each unit individually.  

Make sure all units alarm when each one is tested.

REGULAR MAINTENANCE

This unit has been designed to be as maintenance-free as possible, but there are a few  

simple things you must do to keep it working properly.
• 

Test it at least once a week.

• 

Clean the Smoke Alarm at least once a month; gently vacuum the outside of the 

Smoke Alarm using your household vacuum’s soft brush attachment. Test the Smoke 

Alarm. Never use water, cleaners or solvents since they may damage the unit.

• 

If the Smoke Alarm becomes contaminated by excessive dirt, dust and/or grime, and 

cannot be cleaned to avoid unwanted alarms, replace the unit immediately.

• 

Relocate the unit if it sounds frequent unwanted alarms. See “Locations To Avoid For 

Smoke Alarms” for details.

• 

When the battery back-up becomes weak, the Smoke Alarm will “chirp” about once  

a minute (the low battery warning). This warning should last 7 days, but you should 

replace the battery immediately to continue your protection.

Choosing a replacement battery:

Your Smoke Alarm requires one standard 9V battery. The following batteries are acceptable 

as replacements: Duracell #MN1604, (Ultra) #MX1604; Eveready (Energizer) #522, Eveready 

(Energizer) #1222. You may also use a Lithium battery like the Ultralife U9VL-J, U9VL-J-P 

for longer service life between battery changes. 

These batteries are available at many 

local retail stores.

• 

Always use the exact batteries specified by this User’s Manual. DO NOT use 

rechargeable batteries. Clean the battery contacts and also those of the device 

prior to battery installation. Install batteries correctly with regard to polarity  

(+ and -).

• 

Please dispose of or recycle used batteries properly, following any local regula-

tions. Consult your local waste management authority or recycling organization 

to find an electronics recycling facility in your area. DO NOT DISPOSE OF  

BATTERIES IN FIRE. BATTERIES MAY EXPLODE OR LEAK.

• 

Keep battery out of reach of children. In the event a battery is swallowed,  

immediately contact your poison control center, your physician, or the National 

Battery Ingestion hotline at 202-625-3333 as serious injury may occur

 

Actual battery service life depends on the Smoke Alarm and the environment in which it is 

installed. All the batteries specified above are acceptable replacement batteries for this unit. 

Regardless of the manufacturer’s suggested battery life, you MUST replace the battery  

immediately once the unit starts “chirping” (the “low battery warning”).

UNDERSTANDING THE INDICATOR LIGHTS AND  
ALARM HORN PATTERNS

Condition

LED (Red or Green 

Lights)

Horn

Normal Operation 

(AC Power) 

Green LED ON; flashing 

Red LED once/ minute

No Audible Alarm

DURING TESTING

Red LED flashes 

once every second

Horn pattern:  

3 beeps, pause, 3 beeps, 

pause

LOW OR MISSING  

BATTERY

Red LED flashes 

once/minute

Horn “chirps”  

once/minute

Normal Operation 

(DC Power)

Green LED OFF; Red LED 

flashes once/minute

No Audible Alarm

ALARM CONDITION 

Smoke Initiating Device

Red LED flashes  

rapidly on the unit 

that triggered the 

Alarm.

Horn pattern:  

3 beeps, pause, 3 beeps, 

pause repeating on all 

Alarms

ALARM CONDITION 

Interconnect Alarm

Red LED on the  

other Alarms in an 

interconnected series 

will be OFF.

Horn pattern:  

3 beeps, pause, 3 beeps, 

pause repeating on all 

Alarms

IN SILENCE MODE

Red LED flashes 

once every 10  

seconds

Horn remains silent for 

up to 10 minutes. Horn 

will sound if smoke levels 

increase.

“LATCHING” ALARM  

INDICATOR

Green LED ON for  

2 seconds/OFF for  

2 seconds,  

repeatedly until 

reset, on initiating unit(s).

Horn remains silent

IF THIS SMOKE ALARM SOUNDS, Continued

WHAT TO DO IN CASE OF FIRE

• 

Don’t panic; stay calm. Follow your family escape plan. 

• 

Get out of the house as quickly as possible. Don’t stop to get dressed or collect  

anything.

• 

Feel doors with the back of your hand before opening them. If a door is cool, open 

it slowly. Don’t open a hot door. Keep doors and windows closed, unless you must 

escape through them.

• 

Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.

• 

Meet at your planned meeting place outside your home, and do a head count to make 

sure everybody got out safely.

• 

Call the Fire Department as soon as possible from outside. Give your address, then  

your name.

• 

Never go back inside a burning building for any reason.

• 

Contact your Fire Department for ideas on making your home safer.

 

Alarms have various limitations. See “Limitations of Smoke Alarms” for details.

IF THIS SMOKE ALARM SOUNDS

RESPONDING TO AN ALARM

During an alarm, you will hear a loud, repeating horn pattern: 3 beeps, pause,  

3 beeps, pause.

 

•  If the unit alarms and you are not testing the unit, it is warning you of a  

potentially dangerous situation that requires your immediate attention.  

NEVER ignore any alarm. Ignoring the alarm may result in injury or death.

 

•  Never disconnect the AC power to quiet an unwanted alarm. Disconnecting  

the power disables the Alarm so it cannot sense smoke. This will remove your 

protection. Instead open a window or fan the smoke away from the unit.  

The alarm will reset automatically.

 

• If the unit alarms get everyone out of the house immediately.

 

•  ELECTRICAL SHOCK HAZARD: Attempting to disconnect the power connector 

from the unit when the power is on may result in electrical shock, serious injury 

or death.

When an interconnected system of AC powered units is in alarm, the alarm indicator light on 

the unit(s) that initiated the alarm will blink rapidly. It will remain OFF on any remaining units.
If the unit alarms and you are certain that the source of smoke is not a fire—cooking smoke 

or an extremely dusty furnace, for example—open a nearby window or door and fan the 

smoke away from the unit. Use the Silence Feature to silence the alarm. This will silence the 

alarm, and once the smoke clears the unit will reset itself automatically.

5

“LATCHING ALARM” INDICATOR

IF YOU SUSPECT A PROBLEM

Smoke Alarms may not operate properly because of dead, missing or weak batteries, a 

build-up of dirt, dust or grease on the Smoke Alarm cover, or installation in an improper 

location. Clean the Smoke Alarm as described in “Regular Maintenance,” and install a fresh 

battery, then test the Smoke Alarm again. If it fails to test properly when you use the Test/

Silence button, or if the problem persists, replace the Smoke Alarm immediately.

• 

If you hear a “chirp” once a minute, replace the battery.

• 

If you experience frequent non-emergency alarms (like those caused by cooking 

smoke), try relocating the Smoke Alarm.

• 

If the alarm sounds when no smoke is visible, try cleaning or relocating the 

Smoke Alarm. The cover may be dirty.

• 

If the alarm does not sound during testing, make sure it is receiving AC power 

from the household current.

 

Always discharge the branch circuit before servicing an AC or AC/DC Smoke Alarm.  

First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery 

from Smoke Alarms with battery back-up. Finally, press and hold the test button for 5-10 

seconds to discharge the branch circuit.

Do not try fixing the alarm yourself – this will void your warranty!

If the Smoke Alarm is still not operating properly, and it is still under warranty, please see 

“How to Obtain Warranty Service” in the Limited Warranty.

RECOMMENDED LOCATIONS FOR SMOKE ALARMS

Installing Smoke Alarms in Single-Family Residences

The National Fire Protection Association (NFPA), recommends one Smoke Alarm on every 

floor, in every sleeping area, and in every bedroom. In new construction, the Smoke Alarms 

must be AC powered and interconnected. See “Agency Placement Recommendations” for 

details. For additional coverage, it is recommended that you install a Smoke Alarm in all 

rooms, halls, storage areas, finished attics, and basements, where temperatures normally 

remain between 40˚ F (4.4˚ C) and 100˚ F (37.8˚ C). Make sure no door or other obstruction 

could keep smoke from reaching the Smoke Alarms.

More specifically, install Smoke Alarms:

• 

On every level of your home, including finished attics and basements.

• 

Inside every bedroom, especially if people sleep with the door partly or completely 

closed.

• 

In the hall near every sleeping area. If your home has multiple sleeping areas, install a 

unit in each. If a hall is more than 40 feet (12 meters) long, install a unit at each end.

• 

At the top of the first-to-second floor stairway, and at the bottom of the basement stair-

way.

 

Specific requirements for Smoke Alarm installation vary from state to state and from region 

to region. Check with your local Fire Department for current requirements in your area. 

It is 

recommended AC or AC/DC units be interconnected for added protection.

GARAGE�

BEDROOM

BEDROOM

HALL

LIVING ROOM

KITCHEN

BASEMENT

BEDROOM

LATCHING ALARM: �

Unit was exposed �

to alarm levels of Smoke

LATCHING NOT ACTIVATED: �

Unit was not exposed �

to alarm levels of Smoke

KEY:

The Latching Alarm Indicator

 is automatically activated after an Alarm is exposed to alarm 

levels of smoke. After smoke levels drop below alarm levels, the green LED will be On for 2 

seconds/Off for 2 seconds, repeatedly. This feature helps emergency responders, investiga-

tors, or service technicians identify which unit(s) in your home were exposed to alarm levels 

of smoke after the condition has subsided. The Latching Alarm Indicator stays ON until you 

reset it by pressing the Test/Silence button. The Latching Alarm Indicator is also reset when 

AC and DC power is removed from the Alarm.

USING THE SILENCE FEATURE

The Silence Feature on this unit can temporarily quiet an unwanted alarm for up to 10 minutes.

 

The Silence Feature does not disable the unit—it makes it temporarily less sensitive 

to smoke. For your safety, if smoke around the unit is dense enough to suggest a 

potentially dangerous situation, the unit will stay in alarm or may re-alarm quickly.  

If you do not know the source of the smoke, do not assume it is an unwanted alarm. 

Not responding to an alarm can result in property loss, injury, or death. If the unit will 

not silence and no heavy smoke is present, or if it stays in silence mode continuously, 

it should be replaced immediately.

 

To silence Smoke Alarms in an interconnected series:

1.  To silence multiple alarms in an interconnected series, you must press the Test/Silence 

button on the unit(s) that initiated the alarm.

 NOTE: 

The red LED on the initiating alarm will flash rapidly. The red LED will be Off on 

all other non-initiating alarms. No audible sound will be heard. The unit will exit “silence 

mode” in approximately 10 minutes.

2.  While the unit is in “silence mode”, pressing and holding the Test/Silence button for 

approximately 10 seconds will test the unit. After testing, the unit will re-enter “silence 

mode” and the 10-minute timer is reset.

6

Printed in Mexico 

M08-0134-009   

K1

   11/15

USER’S MANUAL

Smoke Alarms

AC Powered Smoke Alarms 

120V AC 

~

, 60 Hz, 0.04A

Model 9120B

with Battery Back-up  

and Silence

Printed in Mexico 

M08-0134-009   

K1 

  11/15

CONFORMS TO

UL STD 217 

IONIZATION

Model 

9120B

• 

 In air streams near kitchens. Air currents can draw cooking smoke into the sensing 

chamber of a Smoke Alarm near the kitchen.

• 

 In very damp, humid or steamy areas, or directly near bathrooms with showers.  

Keep units at least 10 feet (3 meters) away from showers, saunas, dishwashers, etc.

• 

Where the temperatures are regularly below 40˚ F (4.4˚ C) or above 100˚ F (37.8˚ C) 

including unheated buildings, outdoor rooms, porches, or unfinished attics or  

basements.

• 

 In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm directly over the  

stove or range. Clean a laundry room unit frequently to keep it free of dust or lint.

• 

 Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can blow smoke away 

from the unit, preventing it from reaching sensing chamber.

• 

 In insect infested areas. Insects can clog openings to the sensing chamber and cause 

unwanted alarms.

•   Less than 12 inches (305 mm) away from fluorescent lights. Electrical “noise” can  

interfere with the sensor.

• 

 In “dead air” spaces. “Dead air” spaces may prevent smoke from reaching the Smoke 

Alarm.

AVOIDING DEAD AIR SPACES

“Dead air” spaces may prevent smoke from reaching the Smoke Alarm. To avoid dead air 

spaces, follow the installation recommendations below.

On ceilings,

 install Smoke Alarms as close to the center of the ceiling as possible. If this is 

not possible, install the Smoke Alarm at least 4 inches (102 mm) from the wall or corner.

For wall mounting

 (if allowed by building codes), the top edge of Smoke Alarms should be 

placed between 4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line, below 

typical “dead air” spaces. 

On a peaked, gabled, or cathedral ceiling,

 install the first Smoke Alarm within 3 feet (0.9 

meters) of the peak of the ceiling, measured horizontally. Additional Smoke Alarms may be 

required depending on the length, angle, etc. of the ceiling’s slope. Refer to NFPA 72 for 

details on requirements for sloped or peaked ceilings.

LIMITED WARRANTY

BRK Brands, Inc., (“BRK”) the maker of BRK

®

 brand and First Alert

®

 brand products,  

warrants that for a period of ten years from the date of purchase, this product will be free 

from defects in material and workmanship. BRK, at its option, will repair or replace this 

product or any component of the product found to be defective during the warranty  

period. Replacement will be made with a new or remanufactured product or component. 

If the product is no longer available, replacement may be made with a similar product of 

equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail  

purchase and is not transferable. Keep the original sales receipt. Proof of purchase is 

required to obtain warranty performance. BRK dealers, service centers, or retail stores 

selling BRK products do not have the right to alter, modify or any way change the terms 

and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the 

following: negligent use or misuse of the product, use on improper voltage or current, use 

contrary to the operating instructions, disassembly, repair or alteration by anyone other 

than BRK or an authorized service center. Further, the warranty does not cover Acts of 

God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with 

this unit.
BRK shall not be liable for any incidental or consequential damages caused by the 

breach of any express or implied warranty. Except to the extent prohibited by applicable 

law, any implied warranty of merchantability or fitness for a particular purpose is limited 

in duration to the duration of the above warranty. Some states, provinces or jurisdictions 

do not allow the exclusion or limitation of incidental or consequential damages or limita-

tions on how long an implied warranty lasts, so the above limitations or exclusion may 

not apply to you. This warranty gives you specific legal rights, and you may also have 

other rights that vary from state to state or province to province.

How to Obtain Warranty Service
Service: 

If service is required, do not return the product to your retailer. In order to obtain 

warranty service, contact the Consumer Affairs Division at 1-800-323-9005. To assist 

us in serving you, please have the model number and date of purchase available when 

calling.  

For Warranty Service return to:

 BRK Brands, Inc., 1301 Joe Battle, El Paso, TX 79936

Battery:

 BRK Brands, Inc. make no warranty, express or implied, written or oral, including 

that of merchantability or fitness for any particular purpose with respect to battery.

SPECIAL COMPLIANCE CONSIDERATIONS

This Smoke Alarm is suitable for use in apartments, condominiums, townhouses, hospitals, 

day care facilities, health care facilities, boarding houses, group homes and dormitories 

provided a primary fire detection system already exists to meet fire detection requirements 

in common areas like lobbies, hallways, or porches. Using this Smoke Alarm in common 

areas may not provide sufficient warning to all residents or meet local fire protection  

ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete fire detection systems  

in places housing many people—like apartment buildings, condominiums, hotels, motels, 

dormitories, hospitals, health care facilities, nursing homes, day care facilities, or group 

homes of any kind. It is not a suitable substitute for complete fire detection systems in 

warehouses, industrial facilities, commercial buildings, and special-purpose non-residential 

buildings which require special fire detection and alarm systems. Depending on the building 

codes in your area, this Smoke Alarm may be used to provide additional protection in 

these facilities.
In new construction, most building codes require the use of AC or AC/DC powered Smoke 

Alarms only. In existing construction, AC, AC/DC, or DC powered Smoke Alarms can 

be used as specified by local building codes. Refer to NFPA 72 (National Fire Alarm and 

Signaling Code) and NFPA 101 (Life Safety Code), local building codes, or consult your  

Fire Department for detailed fire protection requirements in buildings not defined as 

“households”.

LIMITATIONS OF SMOKE ALARMS

Smoke Alarms have played a key role in reducing deaths resulting from home fires world-

wide. However, like any warning device, Smoke Alarms can only work if they are properly 

located, installed, and maintained, and if smoke reaches the Alarms. They are not foolproof.

Smoke alarms may not waken all individuals.

 Practice the escape plan at least twice a 

year, making sure that everyone is involved – from kids to grandparents. Allow children to 

master fire escape planning and practice before holding a fire drill at night when they are 

sleeping. If children or others do not readily waken to the sound of the smoke alarm, or if 

there are infants or family members with mobility limitations, make sure that someone is 

assigned to assist them in fire drill and in the event of an emergency. It is recommended 

that you hold a fire drill while family members are sleeping in order to determine their 

response to the sound of the smoke alarm while sleeping and to determine whether they 

may need assistance in the event of an emergency.

Smoke Alarms cannot work without power.

 Battery operated units cannot work if the  

batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the 

batteries are not installed correctly. AC units cannot work if the AC power is cut off for any  

reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical 

fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery 

or AC power, install both types of units.

Smoke Alarms cannot detect fires if the smoke does not reach the Alarms.

 Smoke from 

fires in chimneys or walls, on roofs, or on the other side of closed doors may not reach the 

sensing chamber and set off the Alarm. That is why one unit should be installed inside each 

bedroom or sleeping area—especially if bedroom or sleeping area doors are closed at night—

and in the hallway between them.

Smoke Alarms may not detect fire on another floor or area of the dwelling.

 For example,  

a stand-alone unit on the second floor may not detect smoke from a basement fire until the 

fire spreads. This may not give you enough time to escape safely. That is why recommended 

minimum protection is at least one unit in every sleeping area, and every bedroom on every 

level of your dwelling. Even with a unit on every floor, stand-alone units may not provide as 

much protection as interconnected units, especially if the fire starts in a remote area. Some 

safety experts recommend installing interconnected AC powered units with battery back-up 

(see “About Smoke Alarms”) or professional fire detection systems, so if one unit senses 

smoke, all units alarm. Interconnected units may provide earlier warning than stand-alone  

units since all units alarm when one detects smoke.

Smoke Alarms may not be heard.

 Though the alarm horn in this unit meets or exceeds  

current standards, it may not be heard if: 1) the unit is located outside a closed or partially 

closed door, 2) residents recently consumed alcohol or drugs, 3) the Alarm is drowned out  

by noise from stereo, TV, traffic, air conditioner or other appliances, 4) residents are hearing 

impaired or sound sleepers. Special purpose units, like those with visual and audible alarms, 

should be installed for hearing impaired residents.

Smoke Alarms may not have time to alarm before the fire itself causes damage, 

injury, or death, since smoke from some fires may not reach the unit immediately. 

Examples of this include persons smoking in bed, children playing with matches, or 

fires caused by violent explosions resulting from escaping gas.
Smoke Alarms are not foolproof.

 Like any electronic device, Smoke Alarms are made of  

components that can wear out or fail at any time. You must test the unit weekly to ensure 

your continued protection. Smoke Alarms cannot prevent or extinguish fires. They are not a 

substitute for property or life insurance.

Smoke Alarms have a limited life.

 The unit should be replaced immediately if it is not  

operating properly. You should always replace a Smoke Alarm after 10 years from date of  

purchase. Write the purchase date on the space provided on back of unit.

ABOUT SMOKE ALARMS

Battery (DC) operated Smoke Alarms:

 Provide protection even when electricity fails,  

provided the batteries are fresh and correctly installed. Units are easy to install, and do not 

require professional installation. However, they do not provide interconnected functionality.

AC powered Smoke Alarms: 

Can be interconnected so if one unit senses smoke, all 

units alarm. They do not operate if electricity fails. 

AC with battery (DC) back-up: 

will 

operate if electricity fails, provided the batteries are fresh and correctly installed. AC and 

AC/DC units must be installed by a qualified electrician.

Wireless Interconnected Alarms:

 Offer the same interconnected functionality as with 

hardwired alarms, without wires. Units are easy to install and do not require professional 

installation. They provide protection even when electricity fails, provided the batteries are 

fresh and correctly installed.

Smoke Alarms for Solar or Wind Energy users and battery backup power systems:

  

AC powered Smoke Alarms should only be operated with true or pure sine wave inverters. 

Operating this Smoke Alarm with most battery-powered UPS (uninterruptible power supply) 

products or square wave or “quasi sine wave” inverters 

will damage the Alarm

. If you are 

not sure about your inverter or UPS type, please consult with the manufacturer to verify.

Smoke Alarms for the hearing impaired: 

Special purpose Smoke Alarms should be 

installed for the hearing impaired. They include a visual alarm and an audible alarm horn,  

and meet the requirements of the Americans With Disabilities Act. These units can be inter-

connected so if one unit senses smoke, all units alarm.

Smoke alarms are not to be used with detector guards

 unless the combination has 

been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires if located, installed and 

cared for as described in the user’s manual, and if smoke reaches the Alarm. If you are unsure 

which type of unit to install, refer to NFPA (National Fire Protection Association) 72 (National 

Fire Alarm and Signaling Code) and NFPA 101 (Life Safety Code). National Fire Protection 

Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may 

also require specific units in new construction or in different areas of the home.

LOCATIONS TO AVOID FOR SMOKE ALARMS, Continued

LOCATIONS TO AVOID FOR SMOKE ALARMS

For best performance, AVOID installing Smoke Alarms in these areas:

• 

Where combustion particles are produced. Combustion particles form when something 

burns. Areas to avoid include poorly ventilated kitchens, garages, and furnace rooms. 

Keep units at least 20 feet (6 meters) from the sources of combustion particles (stove, 

furnace, water heater, space heater) if possible. In areas where a 20-foot (6 meter)  

distance is not possible – in modular, mobile, or smaller homes, for example – it is  

recommended the Smoke Alarm be placed as far from these fuel-burning sources as 

possible. The placement recommendations are intended to keep these Alarms at a 

 

reasonable distance from a fuel-burning source, and thus reduce “unwanted” alarms. 

Unwanted alarms can occur if a Smoke Alarm is placed directly next to a fuel-burning 

source. Ventilate these areas as much as possible.

Continued...

AGENCY PLACEMENT RECOMMENDATIONS

NFPA 72 Chapter 29

“For “For your information, the 

National Fire Alarm and Signaling Code

, NFPA 72, reads 

as follows:”

29.5.1* Required Detection.
29.5.1.1*

 Where required by other governing laws, codes, or standards for a specific type 

of occupancy, approved single and multiple-station smoke alarms shall be installed as  

follows:
(1)*In all sleeping rooms and guest rooms
(2)* Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m) of any door  

to a sleeping room, with the distance measured along a path of travel

(3) On every level of a dwelling unit, including basements
(4)  On every level of a residential board and care occupancy (small facility), including  

basements and excluding crawl spaces and unfinished attics

(5)*In the living area(s) of a guest suite
(6)  In the living area(s) of a residential board and care occupancy (small facility)
(Reprinted with permission from NFPA 72

®

, National Fire Alarm and Signaling Code 

Copyright © 2010 National Fire Protection Association, Quincy, MA 02269. This reprinted 

material is not the complete and official position of the National Fire Protection Association, 

on the referenced subject which is represented only by the standard in its entirety), 

(National Fire Alarm and Signaling Code

®

 and NFPA 72

®

 are registered trademarks of the 

National Fire Protection Association, Inc., Quincy, MA 02269).

California State Fire Marshal (CSFM)

Early warning detection is best achieved by the installation of fire detection equipment in all 

rooms and areas of the household as follows: A Smoke Alarm installed in each separate  

sleeping area (in the vicinity, but outside bedrooms), and Heat or Smoke Alarms in the living 

rooms, dining rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms, closets,  

utility and storage rooms, basements, and attached garages.