Page 19
English Customer Service: 1-844-FIRMAN1
Starting the Generator (Recoil Start-Gasoline)
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level and fuel.
9. Pull the starter cord slowly until resistance is
felt and then pull rapidly.
11. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
10. Push the choke button to the “
RUN
” position
.
6
.
Flip
the
engine
switch
to
the “
RUN
"(
l
)
position.
5. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned
on.
3. Make sure the LPG cylinder
knob is fully closed
.
8
.
Pull
the
choke
lever
out
to
the
"
CHOKE
"
position.
7
.
Push the battery power restore switch for about
3 seconds and then release.
Starting the Generator (Recoil Start-LPG)
NOTE
:
hen the fuel
selector switch is in “
GAS
” position(4:30 o’clock).
To close this valve, turn the slector switch to the
“
LPG
” position (1:30 o’clock).
The gasoline valve is OPEN, w
NOTE
: The generator will NOT start with LPG without
battery power or an appropriate connection.
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
4. Turn the fuel selector switch to “
GAS
” position(4:30 o’clock).
Summary of Contents for WH03041
Page 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...
Page 35: ...Page 35 171cc Engine Parts Diagram English Customer Service 1 844 FIRMAN1...
Page 77: ...33 Spanish Servicio al Cliente 1 844 FIRMAN1 171cc Motor Diagrama De Las Piezas...
Page 119: ...33 Fran ais Service Clients 1 844 FIRMAN1 171cc Moteur Sch ma Des Pi ces...