Firman P09201 Operator'S Manual Download Page 12

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

Reduce Risk of Fire

WARNING!

 Exhaust heat/gases could ignite combustibles, structures or damage fuel 

tank causing a fire, resulting in death or serious injury. 

Keep portable generator at least 5 ft. (1.5 m) from any structure, trees or vegetation over 12 
in. (30 cm) in height.

Select an outdoor site that is dry and protected from the weather. Do not move portable 
generator indoors to protect it from the weather.
Do not locate the portable generator under a deck or other similar structure that may 
confine heat and airflow.

11

OPERATION

5  ft.(1.5 m)

min.

5  ft.(1.5 m)

min.

20  ft.(6 m)min.

Summary of Contents for P09201

Page 1: ...P N 392745450 Rev 00 GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P09201 Rev Level 00 OPERATOR S MANUAL...

Page 2: ...ntains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical powe...

Page 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Page 4: ...erator is designed to be used only with FIRMAN authorized parts FIRMAN The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacl...

Page 5: ...ED Extension cords running directly into the home increase your risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is used to power indoor item...

Page 6: ...1 Fuel Gauge 2 9 0 Gallon 34L Capacity Fuel Tank 3 Fuel Cap 5 Fuel Valve 6 Air Filter 7 459cc FIRMAN OHV Engine 8 Recoil Starter 9 11 0 28cm Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Contr...

Page 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Page 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Page 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Page 10: ...grounding requirements 2 3 4 5 9 10 11 1 6 7 8 12 13 3 Battery Switch Power the electric starter 4 Remote Start Indicator Light The light will light or flash depending on the status of the remote star...

Page 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Page 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Page 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Page 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact FIRMAN custom...

Page 15: ...ative main jet and installation instructions can be obtained by contacting customer service NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Page 16: ...2 Move portable generator outdoors to safe operating location at least 20 ft 6 m from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from the generator Never start or stop the gen...

Page 17: ...apidly 10 Do not over choke As soon as engine starts and warms up move the choke lever to the RUN position 11 Push and release the START button on the remote control 3 to 5 seconds and start The gener...

Page 18: ...r service If GFCI trips while in use reset and test the outlet Electric cords laying on the ground with worn insulation may trip the GFCI only use cords in good condition RESET TEST TEST MONTHLY FOLLO...

Page 19: ...th the largest load first 5 Allow the engine to stabilize 6 Plug in and turn on the next item 7 Allow the engine to stabilize 8 Repeat steps 5 6 for each additional item Surge Protection There is a re...

Page 20: ...show CO ALERT is functioning properly TM Carbon monoxide accumulated around generator Prior to restart move generator to an open outdoor area 20 ft 6 m from occupied spaces with exhaust pointed away...

Page 21: ...off Skip this step and go to step 3 if you are not using Remote Start to shut down the engine Flip the engine switch to OFF O position STOP 3 Electric Start and Recoil Start Operations 4 Flip the batt...

Page 22: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Page 23: ...olonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REAC...

Page 24: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Page 25: ...ARNING Contact with muffler area could cause burns resulting in serious injury Do not tough hot parts It is a violation of California Public Resource Code Section 4442 to use or operate the engine on...

Page 26: ...ffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable generator is kept cle...

Page 27: ...provided 9 Install the spark plug boot onto spark plug The battery powers the starter motor and control module This portable generator is equipped with an automatic battery charging circuit The batter...

Page 28: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Page 29: ...soline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility Engine la...

Page 30: ...e Cylinder 4 Stroke OHV Air Cooled 459cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline 9 U S Gallons 34L 37 2 oz 1 1L Counter Clockwise Facing P T O Float Brushed Polyurethane...

Page 31: ...PARTS DIAGRAM AND PART LIST P09201 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 30...

Page 32: ...459cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 31...

Page 33: ...l Head Bolt M8 60 Nut M8 Bolt M8 16 1 2 1 1 1 1 1 1 1 1 1 1 1 3 1 2 1 1 2 4 2 2 1 1 1 2 1 1 1 1 9 1 1 3 1 2 1 7 2 1 1 1 1 1 1 1 1 2 4 2 NO Part Number Description Qty 36 36 1 36 2 36 3 36 4 37 38 39 4...

Page 34: ...lt M3 6 Rectifier Bridge Charger Control Module Nut M3 Multi Meter Bolt M5 12 CO Alarm Remote Holder Remote Control Engine Switch Battery Switch Indicator Light Bolt M6 22 Flat Washers Spring Pad Nut...

Page 35: ...Comp Camshaft Comp Valve Lifter Push Rod 3 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 5 1 1 1 2 10 2 1 1 2 2 1 1 1 2 1 2 1 1 2 2 1 5 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 2 4 1 1 1 1 1 2 2 55 56 57 57 1 57 2 57 3 57...

Page 36: ...English Customer Service 1 844 FIRMAN1 35 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Page 37: ...pt of your Warranty Registration Card and a copy of your sales receipt from one of FIRMAN s retail locations as proof of purchase Please submit your warranty registration and your proof of purchase wi...

Page 38: ...stallation Use and Maintenance This warranty will not apply to parts and or labor if your product is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s...

Page 39: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Page 40: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Page 41: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria A...

Reviews: