Firman P08004 Owner'S Manual Download Page 17

Page 15

Altitude main jet 1

Altitude main jet 2

439cc

380717002

380717003

Altitude

3000-6000Feet

6000-8000Feet

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

OPEN

WARNING

Grounding

The National Electric Code requires your generator 
must be properly connected to an appropriate 
ground to help prevent electric shock.

Failure to properly ground the 
generator can result in electric 
shock.

WARNING

THERE IS A PERMANENT CONDUCTOR BETWEEN 
THE GENERATOR (STATOR WINDING) AND THE 
FRAME.

Use approved transfer equipment to prevent 
backfeed by isolating generator from electric 
utility workers.
When using generator for backup power, notify 
utility company.
Use a ground fault circuit interrupter (GFCI) in 
any damp or highly conductive area, such as 
metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords 
which are worn,frayed, bare or otherwise 
damaged.
DO NOT operate generator in the rain or wet 
weather.
DO NOT handle generator or electrical cords 
while standing in water, while barefoot, or 
while hands or feet are wet.
DO NOT allow unqualified persons or children 
to operate or service generator.

Connecting to a Building's Electrical System

WARNING

Generator voltage could cause 
electrical shock or burn resulting 
in death or serious injury.





The

 

part

 

number

 

and

 

recommended

 

minimum

 

altitude  for

 

the

 

application

 

of

 

the

 

high

 

altitude

 

carburetor

 

main  jet

 

is

 

listed

 

in

 

the

 

table

 

below

.

main  jet

 

and

 

installation

 

instructions

 

can  be

 

obtained

 

by  contacting

 

Customer

 

Support

Installation

 

instructions  are

 

also

 

available

 

in

 

the

 

Technical

 

Bulletin

 

area

 

of

 

the FIRMAN

 

internet

 

site

.

increased

 

exhaust

 

emissions

 

can

 

also

 

result due

 

to

 

the

 

increased

 

enrichment

 

of

 

the

 

air

 

fuel

 

ratio

.

Other

 

high

 

altitude

 

issues

 

can

 

include

 

hard

 

starting

increased

 

fuel

 

consumption

 

and

 

s p a r k

 

p l u g

 

f o u l i n g

T o

 

a l l e v i a t e

 

h i g h

 

a l t i t u d e

 

i s s u e s

 

o t h e r

 

t h a n

 

t h e

 

n a t u r a l

power

 

loss

FIRMAN

 

can

 

provide

 

a  high

 

altitude

 

carburetor

 

main

 

jet

.

 The

 

alternative

 

Summary of Contents for P08004

Page 1: ...and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number PORTABLE GENERATOR MODEL NUMB...

Page 2: ...lectric Start 18 Starting the Generator Remote Start 19 Connecting Electrical Loads 20 Stopping the Engine 20 Low Oil Shutdown 21 Do Not Overload Generator 21 Introduction Battery Cable Connection Con...

Page 3: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Page 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Page 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 6: ...ns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loos...

Page 7: ...T handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaus...

Page 8: ...edical devices or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately...

Page 9: ...C F The generator requires some assembly prior to usage If problems arise when assembling the generator call 1 844 347 6261 F E G H K 1 Before adding wheels tip the generator on its side 2 Slide the...

Page 10: ...nnection NOTE The generator comes equiped with the positive red and negative black cables already attached to battery terminals 1 Cut wire tie that is binding the black battery cables A and B 2 Insert...

Page 11: ...gine 8 Recoil Starter 9 10 0 Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel 13 Handle 14 Battery 15 Remote Holder English Customer Service 1 844 FIRMAN1 We are always working to im...

Page 12: ...voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select button English Customer Service 1 844 FIRMAN1 2 3 4 5 1 120V 30A Twist Lock NEMA L5 30R 120 240V 30A Twist Lock N...

Page 13: ...rained Remote Control Programming 1 Flip the engine switch to the RUN l position NOTE YOUR REMOTE CONTROL IS ALREADY PROGRAMMED IN FACTORYFORYOURCONVENIENCE ANDITISREADYTO STARTTHEGENERATOR Before the...

Page 14: ...hase Power Factor Voltage Regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricating Oi...

Page 15: ...l activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an e...

Page 16: ...k Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or wipe up any sp...

Page 17: ...erwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqual...

Page 18: ...the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the prop...

Page 19: ...ine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 8 Pull the starter cord slowly until resistance is felt and then pull r...

Page 20: ...ct all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip the engine switch to the...

Page 21: ...CONVENIENCE ANDITISREADYTO STARTTHEGENERATOR If the remote control is replaced then you will need to go through programming procedure in Remote Control Programming section 3 Disconnect all electrical...

Page 22: ...ill void warranty CAUTION When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle...

Page 23: ...op the engine Check oil level with dipstick If oil level is between LOW and HIGH mark on dipstick 1 DO NOT try to restart the engine 2 Contact an Authorized FIRMAN Service Dealer 3 DO NOT operate engi...

Page 24: ...ould clean or replace the spark plug and replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better and last longer ITEM NOTES Daily Bef...

Page 25: ...ry animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine c...

Page 26: ...ng CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks co...

Page 27: ...xterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to en...

Page 28: ...sential fuel system parts such as the carburetor fuel hoses or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which le...

Page 29: ...s using a fuel stabilizer A FUEL STABLIZER will minimize the formula tion of fuel gum deposits during storage the fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in...

Page 30: ...tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 10 Wait 5 minutes and re crank engine 11 Contact author...

Page 31: ...Page 29 PARTS DIAGRAM AND PART LIST P08004 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Page 32: ...Page 30 English Customer Service 1 844 FIRMAN1 439cc ENGINE PARTS DIAGRAM...

Page 33: ...74 75 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130...

Page 34: ...buretor Gskt carb Carburetor Choke Connector 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 10...

Page 35: ...Warranty Do Not Return the Unit to the Place of Purchase Contact the FIRMAN Service Center and FIRMAN will troubleshoot any issue via phone or e mail If the problem is not corrected by this method FI...

Page 36: ...apply to parts and or labor if your product is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected inc...

Page 37: ...failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on y...

Page 38: ...ld Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FI...

Page 39: ...P N 380745453 Rev 04 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6...

Reviews: