Firman P04001 Operator'S Manual Download Page 27

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

It is important to prevent gum deposits from forming in essential fuel system components such 
as the carburetor, fuel hoses or tank during storage. Ethanol-blended fuels (called gasohol, ethanol 
or methanol) attract moisture, which leads to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine while in storage.

Long Term Storage

When the generator set is being stored for more than one month, follow these instructions to avoid
engine problems:

Do not store fuel near any ignition sources.
When draining fuel move generator outdoors and use a commercially available non-conductive 
vacuum siphon. Fuel must be drained into an approved container.

WARNING! 

Fuel and its vapors are extremely flammable which could cause burns 

or fire resulting in death or serious injury.

1-Treat any stored fuel with fuel stabilizer.
2-When storing generator with gasoline in fuel tank, operate the engine for 5-10 minutes to 
circulate treated fuel into fuel lines and carburetor before shutdown.
3- There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added.
4-FUEL STARVATION: If you elect to drain fuel tank move generator outdoors. Once fuel tank is 
drained turn fuel valve to on position. Start and run the portable generator outdoors until engine 
stops from lack of gasoline. This will drain remaining gasoline from tank, fuel lines, and carburetor.
5-Always turn fuel valve  to OFF position prior to storage.
6-Allow the portable generator to cool before cleaning and storage.
7-Change oil .
8-Remove spark plug boot and spark plug. Pour about one teaspoon of engine oil through the
spark plug hole, then slowly pull the recoil starter several times to distribute the oil in the cylinder
Pull recoil slowly until resistance is felt. This will close the valves so no moisture enters the engine 
cylinder. Reinstall the spark plug and attach the spark plug boot. 
9-Cover the portable generator and store in a clean, dry place out of direct sunlight and away from 
any ignition sources.
Any damage or hazards caused by using improper fuel, improperly stored fuel, and/or improperly 
formulated stabilizers, are not covered by manufacturer's warranty.
Do not store gasoline from one season to another season.

26

Maintenance - Storage

Summary of Contents for P04001

Page 1: ...P N 340745450 Rev 03 OPERATOR S MANUAL GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P04001 Rev Level 00...

Page 2: ...upport This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supp...

Page 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Page 4: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Page 5: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Page 6: ...OLS 1 Fuel Gauge 2 6 0 Gallon Capacity Fuel Tank 3 Fuel Cap 4 5 6 7 8 Air Filter 223cc FIRMAN OHV Engine Recoil Starter Bottle Opener Remote Holder The remote controller can be placed inside the remot...

Page 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Page 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Page 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Page 10: ...ctrician or authority having jurisdiction for local grounding requirements 10 Outlet Cover Protects the receptacles from dust and debris 8 Circuit Breakers The receptacles are protected by AC circuit...

Page 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Page 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Page 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Page 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Page 15: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Page 16: ...2 Move portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from the generator Never start or stop the gener...

Page 17: ...elease 10 Do not over choke As soon as engine starts and warms up move the choke lever to the RUN position 11 Push and release the START button on the remote control 3 to 5 seconds and start The gener...

Page 18: ...ircuit breaker on control panel is in the closed on position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the...

Page 19: ...generator 18 OPERATION 3 Electric Start and Recoil Start Operations Flip the engine switch to OFF O position The battery switch always should be in OFF O position at the end of use to prevent battery...

Page 20: ...English Customer Service 1 844 FIRMAN1 19 OPERATION 5 Turn the fuel valve to the OFF O position If a cover is used do not install until unit has cooled...

Page 21: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Page 22: ...olonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REAC...

Page 23: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Page 24: ...0 15 mm 0 004 0 006 in 0 10 0 15 mm Muffler and Spark Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do not touch hot parts It is a violation of California Pu...

Page 25: ...rrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable gene...

Page 26: ...Cover the post with boots 9 Install the spark plug wire onto spark plug A M6X12 Battery Charging The battery powers the starter motor and control module This portable generator is equipped with an aut...

Page 27: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Page 28: ...ill fuel tank with gasoline 4 Drain fuel tank and carburetor fill with fresh gasoline 5 Connect wire to spark plug 6 Replace spark plug 7 Drain gas tank and carburetor fill with fresh gasoline 8 Wait...

Page 29: ...gle Cylinder 4 Stroke OHV Air Cooled 223cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline 6 U S Gallons 23L 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethan...

Page 30: ...29 30 31 32 33 34 35 36 37 37 1 37 2 37 3 37 4 38 39 40 40 1 40 2 40 3 40 4 40 5 41 42 44 45 46 47 48 49 49 1 49 2 49 3 49 5 49 6 49 7 50 51 52 49 4 53 54 55 56 57 58 59 60 61 62 63 64 64 2 64 1 64 3...

Page 31: ...3 97 1 97 2 1 2 2 1 2 2 2 3 2 4 4 3 5 7 8 6 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 27 28 29 25 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 6...

Page 32: ...340723001 330713509 FIRMAN 223cc Engine Rubber Cap 2 Rubber Cap1 Alternator Assy Rotor Assy Stator Assy Stator Cover Generator End Cover Flange Bolt M5 12 Flange Bolt M8 252 Ground Wire Flange Bolt M6...

Page 33: ...3581 336713582 336713660 336713614 336713620 336713619 336718350 336713586 340718305 336713564 329713608 Clamp 8 6 Pipe Clip 8 7 8 Remote Holder Remote Control Adapter Holder Socket Waterproof Cover P...

Page 34: ...Bolt governor Arm Spring governor Rod Governor Control Assembly Flange Bolt M6 12 Breather Tube Stud Intake Gasket Inlet Plate Carburetor Insulator Gasket Carburetor Carburetor Gasket Air Cleaner Ste...

Page 35: ...English Customer Service 1 844 FIRMAN1 34 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Page 36: ...future reference Repairs or replacements without prior authorization or at an unauthorized repair facility will not be covered by this warranty Normal Wear Your product needs periodic parts and servic...

Page 37: ...ct Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are h...

Page 38: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Page 39: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Page 40: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC PEORIA AZ 85381 1 844 347 6261 WWW FIRMANPOWEREQUIPMENT COM 87...

Reviews: