9. Do not over-choke. As soon as engine starts
and warms up, move the choke lever to the
“
RUN
” position.
10. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level and fuel.
Starting the Generator (Remote Start)
NOTE:
YOUR REMOTE CONTROL IS ALREADY PROGRAMMED IN
FACTORY FOR YOUR CONVENIENCE. AND IT IS READY TO
START THE GENERATOR.
If the remote control is replaced, then you will
need to go through programming procedure in
"Remote Control Programming" section.
3. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned
on.
5. Flip the engine switch to the “
RUN
”(
l
) position.
4. Turn the fuel valve to the “
ON
” (
l
)position.
7. Push and release the ''
START
'' button on the
remote control. (Remote control is placed inside
the remote holder for your convenience.)
The generator will turn over for 3 to 5 seconds
and start.
.
START
An engine warmup delay is programmed into
the remote start cycle. After the generator is
running, there will be a delay of electrical
output for 15 seconds.
6. Flip the battery power restore switch for about
3 seconds and then release.