Firman P03613 Operator'S Manual Download Page 26

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

It is important to prevent gum deposits from forming in essential fuel system components such 
as the carburetor, fuel hoses or tank during storage. Ethanol-blended fuels (called gasohol, ethanol 
or methanol) attract moisture, which leads to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine while in storage.

Long Term Storage

When the generator set is being stored for more than one month, follow these instructions to avoid
engine problems:

Do not store fuel near any ignition sources.
When draining fuel move generator outdoors and use a commercially available non-conductive 
vacuum siphon. Fuel must be drained into an approved container.

WARNING! 

Fuel and its vapors are extremely flammable which could cause burns 

or fire resulting in death or serious injury.

1-Treat any stored fuel with fuel stabilizer.
2-When storing generator with gasoline in fuel tank, operate the engine for 5-10 minutes to 
circulate treated fuel into fuel lines and carburetor before shutdown.
3- There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added.
4-FUEL STARVATION: If you elect to drain fuel tank move generator outdoors. Once fuel tank is 
drained turn fuel valve to on position. Start and run the portable generator outdoors until engine 
stops from lack of gasoline. This will drain remaining gasoline from tank, fuel lines, and carburetor.
5-Always turn fuel valve  to OFF position prior to storage.
6-Allow the portable generator to cool before cleaning and storage.
7-Change oil .
8-Remove spark plug boot and spark plug. Pour about one teaspoon of engine oil through the
spark plug hole, then slowly pull the recoil starter several times to distribute the oil in the cylinder
Pull recoil slowly until resistance is felt. This will close the valves so no moisture enters the engine 
cylinder. Reinstall the spark plug and attach the spark plug boot. 
9-Cover the portable generator and store in a clean, dry place out of direct sunlight and away from 
any ignition sources.
Any damage or hazards caused by using improper fuel, improperly stored fuel, and/or improperly 
formulated stabilizers, are not covered by manufacturer's warranty.
Do not store gasoline from one season to another season.

25

Maintenance - Storage

Summary of Contents for P03613

Page 1: ...P N 336745462 Rev 00 OPERATOR S MANUAL GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P03613 Rev Level 00...

Page 2: ...ntains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical powe...

Page 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Page 4: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Page 5: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Page 6: ...ghtly from the image on this page 05 FEATURES AND CONTROLS 1 Fuel Gauge 2 5 0 Gallon 19L Capacity Fuel Tank 3 Fuel Cap 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 Bottle Ope...

Page 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Page 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Page 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Page 10: ...n electrician or authority having jurisdiction for local grounding requirements 3 CO Alert Carbon Monoxide CO Shutdown Indicator Light Indicates the engine shutdown due to carbon monoxide accumulation...

Page 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Page 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Page 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Page 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Page 15: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Page 16: ...fuel cap and air cleaner are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from th...

Page 17: ...ectrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 7 Pull the starter cord...

Page 18: ...ircuit breaker on control panel is in the closed on position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the...

Page 19: ...rt below CO Alert DOES NOT replace carbon monoxide alarms Install battery powered carbon monoxide alarm s in your home Don t run generator in enclosed areas Color Description Red Yellow CO Alert fault...

Page 20: ...44 FIRMAN1 19 OPERATION 2 Flip the engine switch to OFF O position If a cover is used do not install until unit has cooled 3 Turn the fuel valve to the OFF O position 2S Do not leave the generator unt...

Page 21: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Page 22: ...rolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REA...

Page 23: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Page 24: ...valve adjustment procedure is on www firmanpowerequipment com 0 004 0 006 in 0 10 0 15 mm Muffler and Spark Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do...

Page 25: ...rrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable gene...

Page 26: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Page 27: ...enerator on level surface 3 Clean or replace air cleaner 4 Fill fuel tank with gasoline 5 Drain fuel tank and carburetor fill with fresh gasoline 6 Connect wire to spark plug 7 Replace spark plug 8 Dr...

Page 28: ...pe Flywheel Magneto Unleaded Automotive Gasoline 5 U S Gallons 19L 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engi...

Page 29: ...PARTS DIAGRAM AND PART LIST P03613 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 28...

Page 30: ...208cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 29...

Page 31: ...nerator End Cover Flange Bolt M8 252 Flange Bolt M6 179 Ground Wire Flange Bolt M6 12 Nut M6 AVR Flange Bolt M5 16 Bolt washer Assemblies Generator End Cover Cap Flange Bolt M5 12 Terminal Block Bolt...

Page 32: ...ing Gear crankshaft Woodruff Key Crankshaft Gear drive Gasket Crankcase Oil Dipstick Assy Cover crankcase Seal Oil Flg Bolt M8 32 Rod Connecting Clip Piston Pin Pin Piston Piston Ring Set Oil Ring The...

Page 33: ......

Page 34: ...English Customer Service 1 844 FIRMAN1 32 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Page 35: ...rts for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to t...

Page 36: ...t Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 West Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are...

Page 37: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Page 38: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Page 39: ...P N 336745462 Rev 00 All rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM...

Reviews: