
English Customer Service: 1-844-FIRMAN1
6. Disconnect all electrical loads from the generator. Never start or stop the generator with
electrical devices plugged in.
7. Move choke lever located on engine to “START” position.
(For electric start move to step (11))
8. For recoil start only - PULL-TO-PRIME Pull the starter cord 1-2 times. Pull slowly until resistance
if felt and then pull rapidly.
1-2 Times
19
OPERATION
9.For recoil start only - Move the choke lever to the “RUN” position.
10. For recoil start only - PULL-TO-RUN Pull the starter cord slowly until resistance if felt and pull
rapidly to run the portable generator.
If the engine fails to start in 1-2 pulls with choke in the RUN position, move choke lever to START
position and repeat the PULL-TO-PRIME step (8).
Summary of Contents for H07553
Page 7: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 06...
Page 8: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 07...
Page 9: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 08...
Page 36: ...439cc DUAL FUEL ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 35...