Firman H05751 Owner'S Manual Download Page 6

Page 03

CORRECT USAGE

Example location to reduce risk of carbon monoxide poisoning

ONLY use outside and downwind, far away from windows, doors and vents.

Direct exhaust away from occupied spaces.

INCORRECT USAGE

Do not operate in any of the following locations:

Near any door, window or vent
Garage
Basement
Crawl Space
Living Area
Attic
Entry Way
Porch 
Mudroom

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

Summary of Contents for H05751

Page 1: ...and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number DUAL FUEL GENERATOR MODEL NUMB...

Page 2: ......

Page 3: ...tion Connecting to a Building s Electrical Maintenance And Storage 27 Maintenance Schedule 27 Engine Maintenance 28 Change Engine Oil 28 Air Filter Maintenance 28 Spark Plug Maintenance 29 Cleaning Fu...

Page 4: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Page 5: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD WARNING WARNING English Customer Service 1 844 FIRMAN1...

Page 6: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 7: ...OR DRAINING GASOLINE Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfi...

Page 8: ...T handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaus...

Page 9: ...Gasoline can cause a fire or explosion if ignited Gasoline is a liquid fuel but it s vapors can ignite Gasoline is a skin irritant and needs to be cleaned up immediately if spilled on skin or clothes...

Page 10: ...N LPG under pressure is highly flammable and can cause a fire or explosion if ignited LPG is heavier than air and can accumulate in confined spaces and low places in the event of a leak LPG has a dist...

Page 11: ...he axle pin A through the wheel B 3 Slide the axle pin A through the mount point on the frame and flat washer D 4 Secure the wheel and axle pin with the cotter pin C 5 Repeat steps 2 4 to attach anoth...

Page 12: ...d 1 Verify the positive battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 2 Remove bolt M5X12 and M5 nut from black cable ring 3 Remove viny...

Page 13: ...Filter 6 439cc FIRMAN OHV Engine 7 Recoil Starter 8 9 10 11 12 13 10 0 Flat Free Wheel Oil Filler Cap Battery Outlet Cover Control Panel Handle 14 LPG Hose Connector Inlet English Customer Service 1 8...

Page 14: ...Starting the engine successfully during these 4 minutes will turn the indicator light GREEN MUST HAVE SOLID RED INDICATOR LIGHT TO BE ABLE TO START THE GENERATOR THE GENERATOR CANNOT BE STARTED DURIN...

Page 15: ...This should stop the flow of electricity making the lamp shut off The GFCI s indicator light comes off RESET TEST TEST MONTHLY FOLLOW DIRECTIONS RESET BUTTON Receptacle Outlet LED Indicator Light TES...

Page 16: ...llon 37 2 oz 1 1L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 5700 GASOLINE 5700 LPG FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Spark Plug AN IMPORTANT MESSA...

Page 17: ...l activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an e...

Page 18: ...lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke when filling the fuel tank 1 Clean area around fuel fill cap remove cap 2 Slowly add u...

Page 19: ...ut and result in a hazardous condition Do not use tape or any type sealant to seal the LPG hose connections Always position the cylinder so the connection between the valve and the regulator won t cau...

Page 20: ...lso result due to the increased enrichment of the air fuel ratio Other high altitude issues can include hard starting increased fuel consumption and spark plug fouling To alleviate high altitude issue...

Page 21: ...any Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical co...

Page 22: ...the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the prop...

Page 23: ...un at no load for few minutes upon each initial start up to permit engine and generator to stablize StartingtheGenerator RecoilStart LPG 1 Before starting the generator check for loose or missing part...

Page 24: ...EEN 6 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 7 Move choke lever located on engine to START position NOTE D...

Page 25: ...ctor switch is turned to the GAS position the indicator light will become RED up to 4 minutes before goes off Starting the engine successfully during these 4 minutes will turn the indicator light GREE...

Page 26: ...g the engine successfully during these 4 minutes will turn the indicator light GREEN 6 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plug...

Page 27: ...do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during bre...

Page 28: ...STARTED DURING BATTERY POWER SAVING MODE UNLESS THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE GAS OR LPG POSITION Unwanted Shutdown The generator cannot be started...

Page 29: ...ufficient fuel flow to the engine This is not an indication of a problem with the generator but only a problem with the flow of gas from the LPG cylinder If generator performance seems to be deteriora...

Page 30: ...ormance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator abuse or negligence To receive ful...

Page 31: ...o cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine...

Page 32: ...replacement parts Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a fire resulting in death or serious injury and or property Contact with muffler area could cause...

Page 33: ...and attach with the screws Spark arrester screen Flange Screw Battery Replacement 1 Remove the spark plug wire from spark plug 2 Remove the nut and bolt from the negative and positive posts 3 Loosen...

Page 34: ...rator This product is equipped with an automatic battery charging circuit The battery will receive charging voltage when the engine is running The battery will maintain a proper charge if the unit is...

Page 35: ...esh gasoline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility 12...

Page 36: ...Page 33 PARTS DIAGRAM AND PART LIST H05751 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Page 37: ...Page 34 439cc DUAL FUEL ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Page 38: ...Lock Pin Front Cover Plate Frame Nut M8 Flange Bolt M8 35 1 1 5 1 1 1 1 1 1 1 1 1 2 1 2 1 1 3 4 8 4 2 2 2 1 1 5 4 1 19 1 2 1 1 1 2 2 2 1 1 1 4 1 1 4 4 4 1 2 1 1 1 1 1 7 1 1 1 1 1 1 1 1 2 2 2 1 1 8 2...

Page 39: ...1 2 1 1 1 1 2 3 1 1 4 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 3 2 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 Crankcase Comp Locating Pins Oil Level Sensor Flg Bolt M6 12 Cams...

Page 40: ...ranty Do Not Return the Unit to the Place of Purchase Contact the FIRMAN Service Center and FIRMAN will troubleshoot any issue via phone or e mail If the problem is not corrected by this method FIRMAN...

Page 41: ...wear items accessory parts failures due to acts of God and other force majeure events beyond the manufacturer s control problems caused by parts that are not original FIRMAN parts WeareFIRMANPOWER And...

Page 42: ...n emissions related parts is as follows 1 Any warranted part that is not scheduled for replacement as required maintenance in the owner s manual supplied is warranted for the warranty period stated ab...

Page 43: ...esult in eligible warranty service being performed 1 Ignition system including Spark plug Ignition coil 2 Fuel metering system Fuel tank Fuel cap Fuel line and related fittings clamps Carburator assem...

Page 44: ...P N 357745481 Rev 00 Firman Power Equipment Inc Peoria AZ 85381 www firmangenerators com 14131 N Rio Vista Blvd Suite 9...

Reviews: