background image

6

LED AND HORN PATTERNS

LIGHTS

GREEN light ON

YELLOW light blinks once per
minute

YELLOW light blinks during horn
ramp-up.

RED blinks 4 times right after
horn sounds.

YELLOW light flashes 2 times per
minute after horn beeps

YELLOW light flashes 3 times per
minute after horn beeps

YELLOW light flashes constantly
after horn beeps

RED light flashes 4 times right
after horn

RED light flashes 3 times every
10 seconds

RED light flashes 1 time every
10 seconds

SMART BUTTON KEY

Quick push activates a local
Push-to-Test sequence

Press and RELEASE button
before you hear the third chirp.
The system will perform a single
local test cycle.

Quick press will eliminate the
low-battery warning for about 10
hours

Smart Button WILL NOT silence
the low battery chirp! Replace
battery immediately!

Press to check the alarm again.
Replace alarm if it remains in the
fault condition.

Quick press activates CO Reset

Quick press erases the CO
latched signal

Quick press activates Smart
Quiet™ Trigger Alarm locator for
Model COE and COEA alarms.

TING THE CO ALARM 

PROBLEM

SOLUTION

Horn beeps twice a
minute and YELLOW
light flashes.

Push the Smart Button to allow alarm to reset and self
test. If fault signal continues, alarm is no longer providing
protection and must be replaced.

The alarm beeps once a
minute and YELLOW
light flashes.

The battery needs to be replaced. Turn off power and
replace the battery. (See “REPLACING THE BATTERY” in
“TESTING AND MAINTENANCE”.) Push the Smart Button
to temporarily quiet the low battery signal for 10 hours.

The horn beeps once,
then two beeps, then
three beeps, pauses, and
then sounds the full
alarm when using the
Smart Button to test.

The alarm is operating properly. The Firex patented
Horn Ramp-Up feature lets you start the test sequence
and move away from the unit before the full alarm
horn sounds.

Alarm sounds; 
no hazard present.

Take Emergency Safety Actions in all alarm situations! If
no hazard proves to be present: Test the alarm to check
for proper functioning. Clean the alarm. (See TESTING
AND MAINTENANCE.) Check that the alarm is placed
properly. (See AGENCY RECOMMENDATIONS FOR
ALARM PLACEMENT.)

For Technical Support:
PH: (800) 445-8299
Email: technical [email protected]
Website: www.icca.invensys.com/firex

YELLOW light blinks during horn
ramp-up.

RED blinks 4 times right after
horn sounds.

Press and HOLD button. 
The system will perform a single
local test cycle, then repeat the
interconnect test until you release
the button.

WARNING

DO NOT disconnect the battery or AC power

to quiet an unwanted alarm. This will remove
your protection. 
Use Quick Quiet™ False Alarm Control by
pushing the Smart Button.

110-1125C Eng  2/22/06  11:32 AM  Page 6

Summary of Contents for SERIES 10000

Page 1: ...drogen gas If the sensor is working properly it WILL NOT chirp If the alarm chirps during the monthly self testing it is indicating a problem with the unit Refer to the charts on pages 5 and 6 for the...

Page 2: ...r Please provide the telephone num ber of the emergency provider and a qualified technician on each label WHERE TO INSTALL THIS CO ALARM WARNING DO NOT install CO alarms Near bathrooms or in shower ar...

Page 3: ...y Remove arrow tab and close battery door The yellow light will flash as door is closed DANGER ELECTRICAL SHOCK HAZARD Turn off power at the main fuse box or circuit breaker by removing the fuse or sw...

Page 4: ...l condition 4 After following steps 1 3 if your alarm reactivates within a 24 hour period repeat steps 1 3 and call a qualified appliance technician __________________ to inves tigate sources of CO fr...

Page 5: ...ean alarm see Cleaning on page 8 Interconnected smoke heat or CO alarms do not sound when Smart Button is pushed to test units 1 Press and hold the Smart Button longer until the second set of two quic...

Page 6: ...o longer providing protection and must be replaced The alarm beeps once a minute and YELLOW light flashes The battery needs to be replaced Turn off power and replace the battery See REPLACING THE BATT...

Page 7: ...e discussed with ALL members of the household Mild Exposure Slight headache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throbbing headache drowsiness confusion...

Page 8: ...t return an alarm under warranty send the alarm in a well padded envelope with postage prepaid a note describing the nature of the difficulty and proof of date of purchase to In U S In Canada Invensys...

Reviews: