SMOKE ALARM DESCRIPTION

Model GC240

Ionisation 230V AC smoke alarm with
False Alarm Control

Model I240C

Ionisation 230V AC smoke alarm with 9V 
battery back-up and False Alarm Control

Model IAR230C

Ionisation 230V AC smoke alarm with recharge-
able battery backup and False Alarm Control

Model PG240

Optical 230V AC smoke alarm and False Alarm Control

Model PAD240

Optical 230V AC smoke alarm with 9V 

& PADC240

battery back-up with False Alarm Control

Model PAR230

Optical 230V AC smoke alarm with rechargeable 
battery back-up and False Alarm Control

SMOKE ALARM FEATURES

• Interconnects with up to 36 Model GC240, I240C, PG240, PAD240, PADC240,

IAR230C, PAR230 smoke alarms. Unique power connector prevents 
interconnection with incompatible smoke alarms or security systems.

• Tamper-resist bracket quickly snaps into place and serves as a safeguard

against tampering. 

• Multi-purpose green and red LEDs indicate that the smoke alarm is receiving

AC power, working under normal operation, in alarm, or under False Alarm
Control.

• Loud alarm horn—85 decibels at 3 metres (10 feet)—sounds to alert you of

an emergency. 

• Test button checks smoke alarm operation.

• Models GC240, I240C, PADC240 , PG240, PAR230 and IAR230C feature 

False Alarm Control, which, when activated, quiets unwanted alarms for up to 
15 minutes.

• Models I240C, PAD240 and PADC240 will not attach to the mounting bracket

if a battery is not in the battery pocket. These models will also sound a short
beep about once a minute if the battery is weak or improperly connected.

• Models IAR230C and PAR230 include permanent rechargeable

lithium batteries.

IMPORTANT SAFETY INFORMATION

PLEASE READ AND SAVE THESE 

INSTRUCTIONS

W

A

R

N

I

N

G

• AC smoke alarms require constant 230V AC, 50Hz power to operate

properly. Mains-powered smoke alarms WILL NOT work if AC power is not
connected or has failed or been interrupted for any reason. Models I240C,
PAD240 and PADC240 require a working 9-volt battery to operate properly in
the event of a power failure. Models IAR230C and PAR230 require a mini-
mum of 2 full days under mains power to reach full backup capacity. DO
NOT use any other kind of battery except as specified in this manual. DO
NOT connect this smoke alarm to any other type of smoke alarm or auxiliary
device, except those listed in this manual.

• DO NOT remove or disconnect battery or turn off AC power to quiet

unwanted alarms. This will remove your protection. Open windows or fan the air
around smoke alarm to silence it. Models GC240, I240C, IAR230C, PG240,
PAR230 and PADC240 smoke alarms feature a False Alarm Control button which,
when activated, will quiet unwanted alarms for up to 15 minutes. 

• The Push-to-Test button accurately tests all smoke alarm functions.

DO NOT use any other test method. Test smoke alarm weekly to
ensure proper operation. 

• This smoke alarm should be installed only by a qualified

electrician. 

• This smoke alarm is designed to be used inside a single family

household only. In multi-family buildings, each individual living unit
should have its own smoke alarms. Do not install in non-residential build-
ings or places which house many people like hotels, motels, dormitories,
hospitals, nursing homes, or group homes of any kind. This smoke alarm
is not a substitute for a complete alarm system. 

1

USER’S
MANUAL

PLEASE READ AND SAVE

INSTALLER: Please leave this manual with the product.

© 2002 Maple Chase

110-666C

BS5446 : Pt 1 : 2000
LICENSE NO. 7832

Model
I240C, GC240
IAR230C

Ionisation

Models 
PG240, PAD240, PADC240,
PAR230

Optical

Printed

in 

U.S.A.

!

Summary of Contents for GC240

Page 1: ...STRUCTIONS W A R N I N G AC smoke alarms require constant 230V AC 50Hz power to operate properly Mains powered smoke alarms WILL NOT work if AC power is not connected or has failed or been interrupted for any reason Models I240C PAD240 and PADC240 require a working 9 volt battery to operate properly in the event of a power failure Models IAR230C and PAR230 require a mini mum of 2 full days under m...

Page 2: ...used by carelessness or safe ty hazards Smoke may not reach the smoke alarm QUICKLY ENOUGH to ensure safe escape Smoke alarms have limitations This smoke alarm is not fool proof and is not warranted to protect lives or property from fire Smoke alarms are not a substitute for insurance Homeowners and renters should insure their lives and property In addition it is possible for the smoke alarm to fa...

Page 3: ... with smoke alarm operation HOW TO INSTALL THIS SMOKE ALARM DANGER ELECTRICAL SHOCK HAZARD Turn off power at the main fuse box or circuit breaker by removing the fuse or switching the circuit breaker to the OFF position and securing it WARNING Mains operated smoke alarms should be installed by a qualified electrician in accor dance with the Regulations for Electrical Installations published by the...

Page 4: ...ecting maximum wire length between any two is 450 m for 1 5mm2 or 1200 m for 2 5mm2 20 OHMS loop resistance This smoke alarm may be interconnected with as many as 35 other Models GC240 I240C PG240 PAD240 PADC240 IAR230C and PAR230 smoke alarms DO NOT connect to any other type or model smoke alarm Connect smoke alarms to a single AC branch circuit If local codes do not permit be sure the neutral wi...

Page 5: ...an alarm within three seconds after any test button is pushed and the tested smoke alarm sounds 3 If smoke alarm does not sound turn off power at main fuse box or cir cuit breaker and check wiring Retest smoke alarm DANGER If alarm horn sounds and smoke alarm is not being tested the smoke alarm is sensing smoke THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION MAINTENANCE AN...

Page 6: ...LL VOID YOUR GUARANTEE REPAIR CAUTION Do not attempt to repair this smoke alarm Doing so will void your guarantee If smoke alarm is not operating properly see Troubleshooting If neces sary and if still under guarantee return smoke alarm to Sensotec Pack it in a well padded carton and send postage prepaid to Sensotec address at the end of this manual If the smoke alarm is no longer under guarantee ...

Page 7: ...operly attached to connector 3 Clean smoke alarm Smoke alarm beeps about 1 Turn off power and once a minute replace battery See Models I240C and Battery Replacement PAD240 only in the MAINTENANCE AND CLEANING section 2 Clean smoke alarm Models IAR230C and 3 Verify that unit has been PAR230 under mains operation for a minimum of 2 full days If the beeping persists after required charging period ret...

Page 8: ...e states do not allow limita tions on how long an implied warranty lasts so the above limitations may not apply to you IN NO CASE SHALL MAPLE CHASE COMPA NY BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAM AGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT Some states do not allow the exclusion or limitation ...