Firex G-6GC Manual Download Page 6

TESTING THE 

SMOKE ALARM

W

A

R

N

I

N

G

DANGER: If alarm horn sounds, and smoke alarm is not

being tested, the smoke alarm is sensing
smoke. THE SOUND OF THE ALARM HORN
REQUIRES YOUR IMMEDIATE ATTENTION AND
ACTION.

Test each smoke alarm weekly

to be sure it is installed cor-

rectly and operating properly.

Test smoke alarms upon returning from vacation.

Also test

when no one has been in the household for several days.

Stand at arm’s length from the smoke alarm when testing.

The alarm horn is loud to alert you to an emergency. The alarm
horn may be harmful to your hearing.

The Push-to-Test button accurately tests all functions.

NEVER use

an open flame

from a match or lighter to test this smoke alarm.

You may ignite and set fire to the smoke alarm and your home.

Test all smoke alarms weekly as follows:

1. Look at the Push-to-Test button. A light flashing about once a

minute indicates the smoke alarm is receiving 120V AC power.
See LED INDICATORS above.

2. Firmly depress the Push-to-Test button for at least five (5) sec-

onds. The smoke alarm will sound its horn loudly. The alarm
may sound for up to 10 seconds after releasing the Push-to-
Test button.

3. If smoke alarm does not sound, replace the smoke alarm

immediately. If the smoke alarm is under warranty, see warran-
ty information at the end of this manual for more information.

REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST
FUNCTION DOES NOT OPERATE PROPERLY AFTER
FOLLOWING THE PROCEDURES OUTLINED ABOVE (see
REPAIR below).

CLEANING 

In addition to weekly testing, this smoke alarm requires periodic
cleaning. Periodic cleaning will remove dust, dirt, and debris.

DANGER: ELECTRICAL SHOCK HAZARD. Turn off power

at main service panel by removing fuse or
switching appropriate circuit breaker to OFF
position before cleaning smoke alarm.

CLEANING 

Always turn off power to smoke alarm before cleaning. Clean
the smoke alarm at least once a month

to remove dust, dirt, or

debris as follows:

Using the wand attachment of a powerful vacuum cleaner, vacuum

all sides and the cover of smoke alarm. Be sure all the vents are
free of debris.

If necessary, turn off power and use a damp cloth to clean smoke

alarm cover.

IMPORTANT:

Do not attempt to remove the cover or clean inside the
smoke alarm. THIS WILL VOID YOUR WARRANTY.

REPAIR 

CAUTION: Do not attempt to repair this smoke alarm.

Doing so will void your warranty. 

If smoke alarm is not operating properly, see TROUBLESHOOTING on
page 7. If you cannot solve the problem, and if the alarm is still under
warranty, return smoke alarm to Invensys Controls Americas. Pack it
in a well-padded carton, shipping prepaid, to:

Invensys Controls Americas

Product Service Department
28C Leigh Fisher Blvd.
El Paso, TX 79906

If the smoke alarm is no longer under warranty, replace the smoke
alarm immediately with a comparable Firex brand smoke alarm.

!

6

110-427K English  11/8/06  11:03 AM  Page 6

Summary of Contents for G-6GC

Page 1: ...alized smoke alarms with a False Alarm Control or a photoelectric sensor This smoke alarm should be installed only by a licensed quali fied electrician Observe and follow all local and national electrical and building codes for installation This smoke alarm is designed to be used INSIDE a single family household only In multi family buildings each individual living unit should have its own smoke a...

Page 2: ...alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fire Smoke alarms are not a substitute for insurance Homeowners and renters should insure their lives and property In addition it is possible for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly and replace it every 10 years SMOKE ALARM PLACEMENT ...

Page 3: ...highest point measured horizontally Install a smoke alarm in lived in or finished attics NOTE For mobile homes built before 1978 install smoke alarms on inside walls between 4 and 12 inches from the ceiling Older mobile homes have little or no insulation in the ceiling This is especially important if the ceiling is unusually hot or cold 3 Bedroom Bedroom Bedroom Bedroom Kitchen O O O O Δ Living Ro...

Page 4: ...ect wire location shall be in accordance with NEC Article 300 3b THIS SMOKE ALARM SHOULD BE INSTALLED IN ACCOR DANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIA TION S STANDARD 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 Connect smoke alarms to a dedicated AC branch circuit If local codes do not permit be sure the neutral wire is common to both phases Install smoke alar...

Page 5: ...the neutral wire is common to both phases LED INDICATORS This smoke alarm features an LED indicator which can be seen through the Push to Test button The LED indicates the following Blinks once a minute indicating normal operation Blinks once a second smoke alarm senses smoke and simultaneously sounds an audi ble alarm Blinks once approximately False Alarm Control FAC every 10 seconds feature acti...

Page 6: ...for more information REPLACE OR RETURN THE ALARM IF THE PUSH TO TEST FUNCTION DOES NOT OPERATE PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED ABOVE see REPAIR below CLEANING In addition to weekly testing this smoke alarm requires periodic cleaning Periodic cleaning will remove dust dirt and debris DANGER ELECTRICAL SHOCK HAZARD Turn off power at main service panel by removing fuse or switching a...

Page 7: ... use them near flame or sparks Keep electrical appliances in good condition Make sure stoves fireplaces chimneys barbeque grills and other appliances are clean and free of grease Be sure they are properly installed and operating as designed Keep operating portable heaters and burning candles away from combustible materials Watch them carefully Do not overload electrical circuits WHAT TO DO IN CASE...

Page 8: ...use and service for a period of five 5 years from date of purchase Invensys Controls Americas agrees to repair or replace at its option any defective smoke alarm provided that it is returned with postage prepaid and with proof of purchase date to Invensys Controls Americas This warranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product This war...

Reviews: