Also, as required by the California State Fire Marshal:

“Early warning fire detection is best achieved by the installation of fire
detection equipment in all rooms and areas of the household as follows: 
a smoke alarm installed in each separate sleeping area (in the vicinity, but
outside the bedrooms), and heat or smoke alarms in the living rooms, 
dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, 
closets, utility and storage rooms, basements and attached garages.”

Important Smoke Alarm Placement 
and Exception Information

• Install a smoke alarm as close to the center of the ceiling as possible.

If this is not practical, mount no closer than 4 inches from a wall or
corner. Also, if local codes allow, install smoke alarms on walls,
between 4 and 12 inches from ceiling/wall intersections.

• Install a minimum of two smoke alarms in every home, no matter how

small the home.  New construction codes require a minimum of two 
interconnected smoke alarms in newly built homes.

• Install a smoke alarm in each room that is divided by a partial wall

(either coming down from the ceiling at least 24 inches, or coming 
up from the floor). 

• Install smoke alarms on peaked, cathedral, or gabled ceilings 3 feet

from the highest point (measured horizontally). 

• Install a smoke alarm in lived-in attics or attics which house electrical

equipment like furnaces, air conditioners, or heaters.

Compliance and Proper Applications

• This smoke alarm is designed to be used inside a single-family house-

hold. In multi-family buildings, each individual living unit should have 
its own alarms. It is not a substitute for a complete commercial alarm
system. It should be used only as 

supplemental

protection in hotels,

motels, dormitories, hospitals, nursing homes, or group homes.

• This product is intended for use in ordinary indoor locations of 

family living units. It is not designed to measure compliance with
Occupational Safety and Health Administration (OSHA) commercial 
or industrial standards.

WARNING

DO NOT Install Smoke Alarms:

• In areas with high humidity (bathrooms or areas near dishwashers or

washing machines). Install at least 10 feet (3 meters) away from
these areas if possible. Note: Steam and aerosol sprays can disable
the alarm.

• Near air returns or within 3 feet (1 meter) of heating and cooling supply

vents. The air could blow smoke away from the alarm, interrupting
its alarm.

• In extremely dusty, dirty, or insect-infested areas. Loose particles 

interfere with smoke alarm operation.

• Within 3 feet (1 meter) of fluorescent lighting. Electrical noise may

cause nuisance alarms.

• With alarm guards unless the combination of alarm and guard has

been evaluated and found suitable for that purpose.

• In closets, crawlspaces, unused attics, or unheated areas where sur-

rounding air temperatures may go below 40ºF (4.4ºC) or above 100ºF
(37.8ºC).

• Within five feet of any fuel-burning appliance (stove, kerosene heater,

furnace, fireplace, etc.).

• Within one foot of any wall, corner, or other dead air space.

• In rooms where chemicals or cleaning supplies are frequently used

(paint, hair spray, thinner, etc.). Allow plenty of ventilation in rooms
where chemicals are used.

• Directly above a sink, bathtub or basin.

• Directly above or below air exchanges or heating vents.

• Behind drapes, furniture, or appliances that could block air flow 

to the alarm.

• This smoke alarm cannot be used in recreational vehicle 

applications.

KITCHEN

DINING 
ROOM

BEDROOM

BEDROOM

BEDROOM

LIVING ROOM

BEDROOM

BEDROOM

LIVING
ROOM

DINING
ROOM

BASEMENT

HALL

/

TV ROOM

DINING 
ROOM

KITCHEN

BEDROOM

BEDROOM

BEDROOM

LIVING ROOM

For best protection, install a smoke alarm in EVERY room. 

In addition,

we recommend that all smoke alarms be interconnected.

SMOKE ALARM

COMBO SMOKE/CARBON MONOXIDE ALARM 

Key

CARBON MONOXIDE ALARM 

Summary of Contents for FADCP

Page 1: ...hen quiet the local unit while the remote units alarm Quick Quiet False Alarm Control Quiets nuisance alarms for up to 15 minutes Smart Quiet Low Battery 1 Allows the homeowners to silence the low battery chirp for up to 10 hours giving them time to go back to sleep and or purchase a fresh replacement battery Smart Quiet Low Battery 2 Indicates the battery no longer has enough voltage to adequatel...

Page 2: ...ition special problems requiring engineering judgment such as locations in attics and in rooms with high ceiling are not covered Smoke Alarms or Smoke Detector Mounting Dead Air Space The smoke from a fire generally rises to the ceiling spreads out across the ceiling surface and begins to bank down from the ceiling The corner where the ceiling and wall meet is an air space into which the smoke cou...

Page 3: ...ntended for use in ordinary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards WARNING DO NOT Install Smoke Alarms In areas with high humidity bathrooms or areas near dishwashers or washing machines Install at least 10 feet 3 meters away from these areas if possible Note Steam a...

Page 4: ...ADCP requires constant 120 volt AC power AND OR a working 9 volt battery to operate properly The alarms WILL NOT work if AC power is not connected or has failed or been interrupted for any reason and the battery is removed drained or improperly connected DO NOT use any other kind of battery except as specified in this manual Connect CO and smoke alarms to a single dedicated AC branch circuit If lo...

Page 5: ...OUTSIDE the building 5 DO NOT GO BACK INSIDE A BURNING BUILDING TO TEMPORARILY SILENCE AN ALARM NOTE These features temporarily quiet alarms but do not disable the sensor When you push the Smart Button during an alarm one of two things will happen 1 All interconnected alarms are silenced This means you pushed the button on the unit that actually triggered the alarm Quick Quiet False Alarm Control ...

Page 6: ...e Smart Button to allow alarm to reset and self test If fault signal continues alarm is no longer providing protection and must be replaced The alarm beeps once a minute and YELLOW light flashes The battery needs to be replaced Turn off power and replace the battery See REPLAC ING THE BATTERY in TESTING AND MAINTE NANCE page 7 Push the Smart Button to temporarily quiet the low battery signal for 1...

Page 7: ...l is two chirps every minute and a flashing yellow LED every 10 seconds See Troubleshooting section for more help To make the signal last longer simply skip step 2 and just continue to hold the push to test button until you are satisfied with the test Maintenance and Care DANGER ELECTRICAL SHOCK HAZARD Turn off power at main service panel by removing fuse or switching appropriate circuit breaker t...

Page 8: ...agrees to repair or replace at its option any defective smoke alarm provided it is returned with postage prepaid and with proof of purchase date to Invensys Controls This warranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIES OF MERCHA...

Reviews: