IMPORTANT SAFETY INFORMATION

PLEASE READ AND SAVE 

THESE INSTRUCTIONS

W

A

R

N

I

N

G

This smoke alarm requires constant 120-volt, AC power AND a
working 9-volt battery to operate properly.

This smoke alarm WILL

NOT work if AC power is not connected or has failed or been interrupt-
ed for any reason AND the battery is removed, drained or improperly
connected. DO NOT use any other kind of battery except as specified in
this manual. DO NOT connect this smoke alarm to any other type of
smoke alarm or auxiliary device, except those listed in this manual.

DO NOT remove or disconnect battery or turn off AC power to
quiet unwanted alarms. 

This will remove your protection. Open 

windows or fan the air around smoke alarm to silence it. This smoke
alarm features a False Alarm Control button which, when activated,
will quiet unwanted alarms for up to 15 minutes.

The Push-to-Test button accurately tests all smoke alarm func-
tions. 

DO NOT use any other test method.

Test smoke alarm

weekly to ensure proper operation. 

This smoke alarm should be installed only by a licensed, quali-
fied electrician. 

Observe and follow all local and national electrical

and building codes for installation.

This smoke alarm is designed to be used inside a single family
household only. 

In multi-family buildings, each individual living unit

should have its own smoke alarms. Do not install in non-residential
buildings or places which house many people like hotels, motels, 
dormitories, hospitals, nursing homes, or group homes of any kind.
This smoke alarm is not a substitute for a complete alarm system.

Install a smoke alarm in every room and on every level of the
home.

Smoke may not reach the smoke alarm for many reasons. For

example, if a fire starts in a remote part of the home, on another level,
in a chimney, wall, roof, or on the other side of a closed door, smoke
may not reach the smoke alarm in time to alert household members.
A smoke alarm will not promptly detect a fire EXCEPT in the area or
room in which it is installed.

Interconnected smoke alarms installed in every room and on
every level of the household offer maximum protection.

The

National Fire Protection Agency (NFPA) recommends interconnecting
smoke alarms so that when one smoke alarm senses smoke and
sounds its alarm, all others will sound as well. Do not interconnect
smoke alarms from one individual family living unit to another. Do not
connect this smoke alarm to any other type of alarm or auxiliary device.

Smoke alarms may not alert every household member every
time. 

There may be limiting circumstances where a household

member may not hear the alarm (e.g., outdoor or indoor noise, sound
sleepers, drug or alcohol usage, the hard of hearing, etc.). If you
suspect that this smoke alarm may not alert a household member,
install and maintain specialty smoke alarms. Current studies have
shown smoke alarms may not awaken all sleeping individuals, and
that it is the responsibility of individuals in the household that are
capable of assisting others to provide assistance to those who may
not be awakened by the alarm sound, or to those who may be
incapable of safely evacuating the area unassisted.

Smoke alarms can sound their alarms only when they detect
smoke.

Smoke alarms detect combustion particles in the air. They

do not sense heat, flame, or gas. This smoke alarm is designed to
give audible warning of a developing fire. However, many fires are

!

2

110-1082B  12/12/06  4:01 PM  Page 2

Summary of Contents for FADC

Page 1: ...e previous alarm sound which continually beeped Test button checks smoke alarm operation and activates False Alarm Control feature which quiets unwanted alarms for up to 15 minutes Item 4718 features a latching LED which blinks the initiating alarm s red LED 3 times each minute until manually reset Item 4718 has a ramp up test horn feature which emits 2 reduced volume beeps before reaching the ful...

Page 2: ...on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed Interconnected ...

Page 3: ... in each sleeping room Chapter 2 also reads as follows 2 2 2 1 In new construction where more than one smoke detector is required by 2 2 1 they shall be so arranged that operation of any smoke detector shall cause the alarm in all smoke detectors within the dwelling to sound The NFPA 1993 Edition Appendix A further states The required number of smoke detectors may not provide reliable early warnin...

Page 4: ... Story Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleep ing area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell Typical Two Story or Split Level Home Install a smoke alarm on the ceiling or wal...

Page 5: ... highest point measured horizontally Install a smoke alarm in lived in attics or attics which house electri cal equipment like furnaces air conditioners or heaters DO NOT install smoke alarm Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarms with unwanted alarm control for these areas In areas with high humidity l...

Page 6: ... plate To later engage tamper resist feature twist out and set aside one of the pins molded into the plate Both pins are exactly the same 2 Align recessed slots on plate with mounting holes of a 4 inch octa gon or single gang junction box 3 Gently pull household wires through center hole of plate 4 Secure plate to junction box using mounting screws 5 With a small wire connector connect white wire ...

Page 7: ...re the neutral wire is common to both phases LED INDICATOR S Model FADC features one combined LED indicator The following section explains what condition the LED indicator is describing Constant GREEN on AC power is present GREEN is off AC power is NOT present RED blinks once a minute testing for presence of good battery RED blinks once a second smoke alarm senses smoke and simultaneously sounds a...

Page 8: ... ignite and damage the smoke alarm or your home Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days FIELD TESTING IMPORTANT NOTICE When testing is required in the field by local inspectors or other par ties it should be done using only the Smoke Detector Sensitivity Analyzer model 501 1 manufactured by Gemini Scientific Corporation Fo...

Page 9: ...ute even though the smoke alarm is receiving AC power On item 4718 the red LED will also blink 4 times every minute after each low battery chirp Use only the following batteries as replacements in this smoke alarm Eveready 522 or 1222 Duracell MN 1604 or Ultralife U9VL J WARNING DO NOT USE ANY OTHER TYPE OF BATTERY EXCEPT AS SPECIFIED IN THIS MANUAL DO NOT USE RECHARGEABLE BATTERIES 1 Turn off pow...

Page 10: ...moke alarm and explain what the sound means Determine TWO exits from each room and an escape route to the outside from each exit Teach all household members to touch the door and use an alternate exit if the door is hot INSTRUCT THEM NOT TO OPEN THE DOOR IF THE DOOR IS HOT Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases Determine a safe meeting place ...

Page 11: ... only Be sure red LED is extinguished after replacing battery Smoke alarm sounds 1 Hire an electrician to unwanted alarms inter move smoke alarm to mittently or when a new location See residents are cooking SMOKE ALARM taking showers etc PLACEMENT 2 Clean smoke alarm See Cleaning in the MAINTENANCE AND CLEANING section Interconnected smoke 1 Press and hold test alarms do not sound when button for ...

Page 12: ...ntrols Americas smoke alarm provided that it is returned with postage prepaid and with proof of purchase date to Invensys Controls Americas This warranty does not cover damage resulting from acci dent misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIESOFMERCHANTABILITYANDFITNESSFORAPART...

Reviews: