MAINTENANCE
04-UCBTE018_V1-DIMU-00-EN
71
BY SERVICE TECHNICIAN
For each operation:
Carefully close all the panels. .
The inside of the appliance should be kept clean.
Electrical wiring should be kept securely connected and in good condition.
ANNUAL
CHECKS
/
ACTION
1.
Check coupling panels, must be perfectly closed with all the screws.
2.
Check the sealing water system (load tap water).
3.
Check that terminals connections of electrical parts are well fastened. Clean electrical parts .
4.
Cleaning the fan motor mixer with compressed air or vacuum cleaner.
5.
Verify the integrity of mixer motor electric cable. If damaged, replace it(with original spare parts).
6.
Replace mixer engine gaskets (Annual or after 2700h working mixer). With the key, unscrew the
cap (1) and replace the gaskets (2-3). This maintenance requires the use of suitable grease cod.
70400172.
Attention to closing the cap; Do not force too close (risk of seizing the threads!)