fire's edge 100A-M Owner'S Manual Download Page 3

1.0 

Gas Requirements: 

1.1 

Gas type: 

Natural   

Propane 

1.2 

Gas Pressure: 

7” wc    

11”wc       

1.4 

Gas flow: 

1 Burner System: 

125,000 Btu/hr 

Note: Check with your gas supplier to verify gas flows and pressures available at the location 
of your installation.  In many cases utility companies will install larger meters at no charge to 
accommodate larger flows. 

2.0 

Installation 

Warning: This unit is for outdoor use only 

2.1 

2.2 

2.3 

2.4 

2.5 

2.6 

2.7 

Do not install near any combustibles such as wood structures, fuels, clothing, fabrics   
or dry vegetation. 
Installation shall be performed by a licensed contractor.  All aspects of installation 
must conform to local codes, or in the absence of codes, with National Fuel Gas Code 
ANZI Z223.1. 
An approved gas valve or keyed valve shall be installed upstream of the unit and 
located in an accessible area that is within 5ft from the 

Fire's Edge

 Unit.

Maintain good piping practice by keeping pipe length and elbows to a minimum to     
eliminate unnecessary pressure drops. (Do not use any flexible gas line) 
Install the 

Fire's Edge

 Fire Pit 

(48”

Tacora

/42”- 60”

Terra 

Nova

/42”

Sumaco

/40”-50”

Amiata

/45”

Grand Curacoa

) as shown in Fig. 1. or Fig. 2. 

48”

Tacora

 and 45”

Grand Curacoa

 and 42” 

Sumaco

 require a 

Fire's Edge

 Mounting 

Bracket to be

 

installed. The Mounting Bracket secures bowl and allows for cooling air 

and water drainage. 
Fig.3 and Fig. 4 illustrate requirements for Fire Pits with Manual Burner Inserts. 