3
1.0
Gas Requirements:
1.1
Gas type:
Natural
Propane
1.2
Gas Pressure:
7” wc
11”wc
1.4
Gas flow:
1 Burner System:
125,000 Btu/hr
Note: Check with your gas supplier to verify gas flows and pressures available at the location
of your installation. In many cases utility companies will install larger meters at no charge to
accommodate larger flows.
2.0
Installation
Warning: This unit is for outdoor use only
2.1
2.2
2.3
2.4
2.5
2.6
2.7
Do not install near any combustibles such as wood structures, fuels, clothing, fabrics
or dry vegetation.
Installation shall be performed by a licensed contractor. All aspects of installation
must conform to local codes, or in the absence of codes, with National Fuel Gas Code
ANZI Z223.1.
An approved gas valve or keyed valve shall be installed upstream of the unit and
located in an accessible area that is within 5ft from the
Fire's Edge
Unit.
Maintain good piping practice by keeping pipe length and elbows to a minimum to
eliminate unnecessary pressure drops. (Do not use any flexible gas line)
Install the
Fire's Edge
Fire Pit
(48”
Tacora
/42”- 60”
Terra
Nova
/42”
Sumaco
/40”-50”
Amiata
/45”
Grand Curacoa
) as shown in Fig. 1. or Fig. 2.
48”
Tacora
and 45”
Grand Curacoa
and 42”
Sumaco
require a
Fire's Edge
Mounting
Bracket to be
installed. The Mounting Bracket secures bowl and allows for cooling air
and water drainage.
Fig.3 and Fig. 4 illustrate requirements for Fire Pits with Manual Burner Inserts.