3.01 Environment
This Power Source is designed for use in environments
with increased hazard of electric shock. Additional safety
precautions may be required when using unit in an
environment with increased hazard of electric shock.
Please refer to relevant local standards for further
information prior to using in such areas.
A. Examples of environments with increased hazard of
electric shock are:
1. In locations in which freedom of movement
is restricted, so that the operator is forced to
perform the work in a cramped (kneeling, sit-
ting or lying) position with physical contact with
conductive parts.
2. In locations which are fully or partially limited
by conductive elements, and in which there is
a high risk of unavoidable or accidental contact
by the operator.
3. In wet or damp hot locations where humidity
or perspiration considerably reduces the skin
resistance of the human body and the insulation
properties of accessories.
B. Environments with increased hazard of electric shock
do not include places where electrically conductive parts
in the near vicinity of the operator, which can cause
increased hazard, have been insulated.
3.02 Location
Be sure to locate the welder according to the following
guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 14° F (0° C) to 104°
F (40° C).
C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or
shock.
E. In areas, not exposed to direct sunlight or rain.
SECTION 3: INSTALLATION, OPERATION AND SETUP
F. Place at a distance of 12" (305mm) or more from
walls or similar that could restrict natural air flow
for cooling.
G. The enclosure design of this Power Source meets the
requirements of IP23S as outlined in EN 60529. This
provides adequate protection against solid objects
(greater than 1/2", 12mm) and direct protection from
vertical drops. Under no circumstances should the
Power Source be operated or connected in a micro
environment that will exceed the stated conditions.
For further information please refer to EN 60529.
H. Precautions must be taken against the power source
toppling over. The power source must be located on
a suitable horizontal surface in the upright position
when in use.
WARNING
This equipment should be electrically con-
nected by a qualified electrician.
3.03 Ventilation
!
WARNING
Since the inhalation of welding fumes can
be harmful, ensure that the welding area is
effectively ventilated.
3.04 Electricity Supply
The Electricity Supply voltage
should be within 208/230V AC ± 15% or 115 V AC ±
15%. Too low a supply voltage may cause poor welding
performance in STICK mode such as the arc snuffing
out during welding. Too high a supply voltage will cause
components to overheat and possibly fail. The Welding
power Source must be:
• Correctly installed, if necessary, by a qualified electri
-
cian.
• Correctly earthed (electrically) in accordance with
local regulations.
• Connected to the correct size power point and fuse as
per the Specifications on page 2-4.
Summary of Contents for MST 220i
Page 6: ...This Page Intentionally Blank...
Page 80: ...FIREPOWER MST 220i BASIC WELDING 4 22 Manual 0 5343 This Page Intentionally Blank...
Page 90: ...FIREPOWER MST 220i REPLACEMENT PARTS 6 4 Manual 0 5343 This Page Intentionally Blank...
Page 92: ...FIREPOWER MST 220i APPENDIX A 2 Manual 0 5343 This page intentionally blank...
Page 94: ...This page intentionally blank...