500-880MM ADJUSTABLE LENGTH
Code:02-***-014
Adjustable lengths come with
two
locking bands – distance to combustibles
remains at 50mm, the same as all standard lengths.
Each adjustable length comes with an extra short length of rockwool which gets
compressed to ensure insulation continues throughout. Care must be taken to
ensure that when assembled to required length no air gaps are left.
There is a high-temp plastic seal in the adjustable length locking band to avoid
any movement once length has been adjusted to required height. The locking
band fits onto the lower lip of the pipe.
350-500MM ADJUSTABLE LENGTH
Code:02-***-015
250-350MM ADJUSTABLE LENGTH
Code:02-***-016
500MM TESTING LENGTH
Code:02-***-019
Working length 457mm, including analysis port
PELLET GASKET
Code:15-***-102
A rubber seal used on condensing installations to stop the condensates from
penetrating the flue. The Product Designation for Clearline AKW with seals fitted
for condensing appliances is:
EN1856-2 T200-P1-W-V2-L50040 0(20)