![FireplaceXtrordinair 44-Elite Installation Manual Download Page 16](http://html1.mh-extra.com/html/fireplacextrordinair/44-elite/44-elite_installation-manual_2291994016.webp)
16
Installation
(for qualified installers only)
© Travis Industries
4050714
93508093
Chimney Requirements
Approved Chimney Brands
•
Use one of the following brands and type of chimney:
- Temco 82 - Firecraft FTF8 (Superior TF8) - FMI 8DM - Marco 8D
Chimneys Part Numbers
Chimney Components
Temco 82 Firecraft FTF8
FMI 8DM
Marco 8D
12" Chimney Section
8212D
TF8-12
12-8DM
12 - 8D
18" Chimney Section
8218D
TF8-18
18-8DM
18 - 8D
24" Chimney Section
8224D
---
24-8DM
----
36" Chimney Section
8236D
TF8-36
36-8DM
36 - 8D
48" Chimney Section
8248D
TF8-48
48-8DM
48 - 8D
Offsets
8232E
TF8-30, TF8-E30
30E-8DM
30E - 8D
Flashing
8206F
8-F6
6F8 or 12F8
12F - 8D
Chimney Cap8203D
TF8-CTO
RTL-8
DM
BT - 8D
Roof Support
8204S
8-54
38 RS
12CPS - 8D
Firestop Spacer
---
8FS-2
FS-8DM
FS30 - 8D
Chimney Installation
•
Each brand of chimney has a slightly different outside diameter. To accommodate this, the
fireplace has three "L" brackets (outer liner connectors) on the top of the fireplace can. Center
a section of chimney over the chimney opening and mark the exterior location of the chimney.
Reposition the "L" brackets, if necessary, so they are adjacent the exterior of the chimney (see
Figure 19).
Outer Pipe Brackets
Use sheet metal screws to attach
the outer liner to these brackets.
Inner Liner (ledge along
inside accepts differed
sized chimney pipes)
If the outer pipe does not line up
with the brackets, remove the
brackets and re-attach them to
the top of the fireplace.
Connect the inner pipe to
the inner liner with three
sheet metal screws.
Figure 19
•
When attaching the chimney to the fireplace, first slide down the inner liner of the chimney
pipe into the inner liner of the fireplace. Certain brands of chimney pipe will stop at the ledge,
while others will insert beyond the ledge. When the chimney pipe is fully seated and aligned,
drill three holes in the chimney pipe where it lines up with the holes in the fireplace inner liner.
Secure the fireplace to the chimney pipe with three sheet metal screws. If there are any large
gaps between the chimney pipe and fireplace, use furnace cement to seal (allow 24 hours to
dry before burning the fireplace).
•
Depending on the manufacturer and where the chimney is to be installed, chimney supports,
roof braces, radiation shields, attic insulation shields, attic enclosures, spark arrestors, locking
bands, etc... may be required as part of the chimney system. The manufacturer's installation
instructions, which are reviewed by the listing agency, specifies when and where each of these
components must be used. Follow the manufacturer's instructions for the use of flashing and an
adjustable storm collar at the roof line to prevent water from entering the house. Manufacturers
require that chimneys extending beyond a certain height above the roof (frequently above 5')
must also be braced.