FireplaceXtrordinair 44-Elite Installation Manual Download Page 16

16

Installation 

 (for qualified installers only)

© Travis Industries

4050714

93508093

Chimney Requirements

Approved Chimney Brands

 

Use  one  of  the  following  brands  and  type  of  chimney:
- Temco 82          - Firecraft FTF8 (Superior TF8)          - FMI 8DM          - Marco 8D

Chimneys Part Numbers

Chimney  Components

Temco  82 Firecraft  FTF8

FMI  8DM

Marco  8D

12"  Chimney  Section

8212D

TF8-12

12-8DM

12 - 8D

18"  Chimney  Section

8218D

TF8-18

18-8DM

18 - 8D

24"  Chimney  Section

8224D

---

24-8DM

----

36"  Chimney  Section

8236D

TF8-36

36-8DM

36 - 8D

48"  Chimney  Section

8248D

TF8-48

48-8DM

48 - 8D

Offsets

8232E

TF8-30, TF8-E30

30E-8DM

30E - 8D

Flashing

8206F

8-F6

6F8 or 12F8

12F - 8D

Chimney  Cap8203D

TF8-CTO

RTL-8

DM 

BT - 8D

Roof  Support

8204S

8-54

38 RS

12CPS - 8D

Firestop  Spacer

---

8FS-2

FS-8DM

FS30 - 8D

Chimney Installation

 

Each  brand  of  chimney  has  a  slightly  different  outside  diameter.    To  accommodate  this,  the
fireplace  has  three  "L"  brackets  (outer  liner  connectors)  on  the  top  of  the  fireplace  can.    Center
a  section  of  chimney  over  the  chimney  opening  and  mark  the  exterior  location  of  the  chimney.
Reposition  the  "L"  brackets,  if  necessary,  so  they  are  adjacent  the  exterior  of  the  chimney  (see
Figure  19).

Outer Pipe Brackets

Use sheet metal screws to attach 
the outer liner to these brackets.

Inner Liner (ledge along 
inside accepts differed 
sized chimney pipes)

If the outer pipe does not line up 
with the brackets, remove the 
brackets and re-attach them to 
the top of the fireplace.

Connect the inner pipe to 
the inner liner with three 
sheet metal screws.

Figure 19

 

When  attaching  the  chimney  to  the  fireplace,  first  slide  down  the  inner  liner  of  the  chimney
pipe  into  the  inner  liner  of  the  fireplace.    Certain  brands  of  chimney  pipe  will  stop  at  the  ledge,
while  others  will  insert  beyond  the  ledge.    When  the  chimney  pipe  is  fully  seated  and  aligned,
drill  three  holes  in  the  chimney  pipe  where  it  lines  up  with  the  holes  in  the  fireplace  inner  liner.
Secure  the  fireplace  to  the  chimney  pipe  with  three  sheet  metal  screws.    If  there  are  any  large
gaps  between  the  chimney  pipe  and  fireplace,  use  furnace  cement  to  seal  (allow  24  hours  to
dry  before  burning  the  fireplace).

 

Depending  on  the  manufacturer  and  where  the  chimney  is  to  be  installed,  chimney  supports,
roof  braces,  radiation  shields,  attic  insulation  shields,  attic  enclosures,  spark  arrestors,  locking
bands,  etc...  may  be  required  as  part  of  the  chimney  system.    The  manufacturer's  installation
instructions,  which  are  reviewed  by  the  listing  agency,  specifies  when  and  where  each  of  these
components  must  be  used.    Follow  the  manufacturer's  instructions  for  the  use  of  flashing  and  an
adjustable  storm  collar  at  the  roof  line  to  prevent  water  from  entering  the  house.    Manufacturers
require  that  chimneys  extending  beyond  a  certain  height  above  the  roof  (frequently  above  5')
must  also  be  braced.

Summary of Contents for 44-Elite

Page 1: ...A AA AA AA AAA AAA AAA AAA AAA AAA AAA AAA 44 Elite Installation Manual 4800 Harbour Pointe Blvd SW Mukilteo WA 98275 Wood Burning Zero Clearance Fireplace 2007 Travis Industries 10 00 93508093 Tested...

Page 2: ...wood heater in a manner inconsistent with operating instructions in the owner s manual or if the catalytic element is deactivated or removed Do not use a fireplace insert or other products not specif...

Page 3: ...ireplace Placement 11 Clearances 12 Raised Fireplaces 12 Cooling Vent Requirements 13 Blower Requirements 14 Blower Duct Routing 14 Blower Duct Connection 15 Blower Electrical Connection 15 Chimney Re...

Page 4: ...d Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney...

Page 5: ...700 Heating capacity will vary with floor plan insulation and outside temperature Dimensions 8 Blower Lead 8 Electrical Input Lead 6 1 2 46 26 1 8 49 24 31 1 2 Includes the 1 2 stand offs 44 The set u...

Page 6: ...or Blower Two 10 Flex Ducts 7 Diameter For Cooling Vents Two Vent Hoods For Cooling Vents Two Vent Hood Storm Collars For Cooling Vents Faceplate Gasket Items Shipped with the Faceplate Faceplate two...

Page 7: ...the section Minimum Clearances See the section Chimney Requirements See the section Hearth Requirements See the section Blower Requirements See the section Cooling Vent Requirements See the section Mi...

Page 8: ...A A A A AAAAAAAAAAAAAAAAAA AAAAA AA AA AA AA AA Fireplace Interior of Home Internal Blower Exterior Wall Exterior Figure 5 Cooling Air P Trap When installing the cold air ducts make sure to include a...

Page 9: ...ir can be heated by the house causing syphoning This pulls cool air through the cooling channel leading to fireplace cooling Cooling air is required by the fireplace to prevent overheating Negative pr...

Page 10: ...pe to header clearance A firestop is required at the top of the fireplace enclosure or ceiling level whichever is lower Min 4 1 2 NOTE make sure the enclosure is wide enough to accommodate the blower...

Page 11: ...so located on back The fireplace and firebox must be made level and plumb during installation Use shims under the fireplace to properly level the fireplace Zero Clearance Can Firebox WARNING Failure t...

Page 12: ...y from high traffic areas Fireplace must be placed so the vents below and above the glass do not become blocked Raised Fireplaces If the fireplace is raised the fireplace enclosure must be raised as w...

Page 13: ...0 0 and 1 25 Included with the fireplace are two 12 lengths of vent use a connector and seal if adding more length The duct terminations must be located so they can not be blocked e g snow drifts Incl...

Page 14: ...ower duct is 15 use the included duct start collar The maximum length for 8 diameter blower duct is 25 use two 6 to 8 adapters NOTE The shorter the blower duct the greater the air flow A maximum of tw...

Page 15: ...how the homeowner the blower location and inform them of the need to clean periodically Remove the four screws that go into these holes Shake the filter to remove any dirt that may have accumulated In...

Page 16: ...pipes If the outer pipe does not line up with the brackets remove the brackets and re attach them to the top of the fireplace Connect the inner pipe to the inner liner with three sheet metal screws Fi...

Page 17: ...ght above the specified minimum may be necessary to reduce wind induced down drafting and back puffing or to increase draft thereby improving fireplace operating characteristics Chimney must be totall...

Page 18: ...walls The table below details the amount of offset X and rise R gained from various chimney lengths when used with 30 elbows see Figure 21 Make sure to add the amounts for both elbows Two sections may...

Page 19: ...bove the fireplace before the chimney penetrates the ceiling use a firestop the chimney must maintain the clearances listed below 5 to the rear of the chimney 4 1 2 to the front of the chimney Min Cle...

Page 20: ...a sloped roof it is important to determine the size of the framing for clearance purposes Use the appropriate column for 2 x 4 or 2 x 6 rafters It is not necessary to frame around the hole opening if...

Page 21: ...se is above the roof structure The chimney cap must still maintain the 2 3 10 clearance to any other structure See the illustration below Chimneys extending beyond a certain height frequently 5 above...

Page 22: ...quires 1 2 thick concrete board or other non combustible to extend from the header to the base of the fireplace and to the framing members on both sides do not use sheetrock or drywall See Figure 27 T...

Page 23: ...et the mantel requirements listed in this manual To achieve a facing that is flush with the drywall to the side of the fireplace recess the framing directly next to the fireplace see Figure 28 1 2 Dry...

Page 24: ...above the base See Figure 29 The mantel must not extend more than 8 1 2 in front of the faceplate Mantel side columns that extend more than 3 4 beyond the faceplate must maintain an 18 clearance to t...

Page 25: ...rth material can go above this point Fireplace Faceplate Ember Strip 6 1 2 Max 18 Min Check Local Building Codes AA AA AA AAAAAAAAA AAAAAAAAA A A A A AAAAAAAAA AAAAAAAAA AA AA AA Minimum 1 cement boar...

Page 26: ...raps in the fireplace Treated wood breaks down the catalyst inside the fireplace decreasing efficiency and increasing emissions Remove Set Up Face Remove the set up face using a phillips screwdriver s...

Page 27: ...8 allen wrench Install the baffle and grate AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA A A A A A AAAA AAAA AAAA...

Page 28: ...h the gasket onto the back of the face note how the holes on the gasket line up with the holes on the face The 36 is pictured the 44 installs in a similar fashion Attach the side gaskets in the same f...

Page 29: ...h the faceplate see Figure 34 NOTE do not pinch any of the wires in the lower right between the faceplate and the fireplace AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA A...

Page 30: ...ick connects from the switch plate to the two female quick connects leading from the fireplace These male quick connects are for the summer fan switch connect them together to test if the blower opera...

Page 31: ...it between the door gasket and the fireplace Adjustments are made to the door latch by moving the washers from either side of the door latch and tightening the inner nut against the outer nut The door...

Page 32: ...ent Requirements 10 Fireplace Placement 11 Firestops 20 Framing Dimensions at 45 10 Framing the Roof 20 Hearth Requirements 25 Heating Specifications 6 Install the Faceplate Insulation 28 Installation...

Reviews: