FireplaceXtrordinair 36E - ZC Builder Booklet Download Page 8

TM

  36E - ZC Builder Booklet

Page 8

Part # 17601184

© 2001, Travis Industries, Inc.

Printed 9/24/04

Chimney Requirements

 

Use one of the following brands and type of chimney:  • Temco 82  • Superior TF8  • FMI 8DM  • Marco 8D

 

Depending on the manufacturer and where the chimney is to be installed, chimney supports, roof braces,
radiation shields, attic insulation shields, attic enclosures, spark arrestors, locking bands, etc... may be
required as part of the chimney system.  The manufacturer's installation instructions, which are reviewed by
the listing agency, specifies when and where each of these components must be used.  Follow the
manufacturer's instructions for the use of flashing and an adjustable storm collar at the roof line to prevent
water from entering the house.  Manufacturers require that chimneys extending beyond a certain height
above the roof (frequently above 5') must also be braced.

 

30° Elbows may be used to offset
the chimney (to align the chimney
or gain clearance to combustibles

 

A maximum four 30° elbows may
be used

 

Each elbow must be used in
conjunction with a return elbow
(so the chimney returns to a
vertical direction)

 

If using a single offset (two 30°
elbows) a maximum of 8' of
inclined chimney may be used
between elbows.

 

If using two offsets (four 30°
elbows) a maximum of 4' of
inclined chimney may be used
between each set of elbows.

 

For every 6' of inclined chimney a
flue support is required

 

Elbows may be used directly off
the top of the fireplace (maintain a
5" clearance to combustibles on
the back wall, 4 1/2" minimum on
the front wall and header)

Chimney must be totally 
enclosed when passing 
through living space with a 
minimum 2" clearance to 
combustibles.

3' Min.

2' Min.

10'

System Height
35' Max.
15' Min.

2" Min. Air 
Space to 
Combustibles

Rain Cap

Storm Collar

Flashing

Firestop Required Between 
Floor Levels (or fireplace 
enclosure)

Attic Firestop (with insulation shield)

Cooling 
Vent

2" Min. Air 
Space to 
Combustibles

Maximum 8'  (4' if two pairs of 
30° elbows used)

Maximum 

30°

Summary of Contents for 36E - ZC

Page 1: ...Flush Floor Hearth Internal or External Chase 8 leads for the power source and the blower 120 Volts A C Set up face is included to ease facing installation 3 blower duct locations for a wide selection...

Page 2: ...ear edge Remove the cover plate to access the blower hook up Optional Electrical Conduit Exit Location Electrical Conduit Location 7 5 8 3 1 4 1 1 2 Wide Nail Down Flange Packing List Shipped with the...

Page 3: ...1 Do not build into this area Do not slope the walls inward Framing Dimensions at 45 AAA AAA AAA AAA AAA AAA A A A A A A A A A A AAAAAAAAA 25 1 2 66 1 2 43 26 Fireplace includes 1 2 standoffs 22 1 4 2...

Page 4: ...d the faceplate NOTE the faceplate protrudes 1 from the front of the fireplace has a 1 8 overlap on the sides and 1 4 overlap on top To achieve a facing that is flush with the drywall to the side of t...

Page 5: ...ted above this point 15 Raised hearth 3 4 Plywood AAAAAAAAA AAAAAAAAA A A A Fireplace 2 x 8 Framing Faceplate Ember Strip 15 Raised hearth Elevated hearths must be constructed of non combustible mater...

Page 6: ...25 Included with the fireplace are two 12 lengths of vent use a connector and seal if adding more length The duct terminations must be located so they can not be blocked e g snow drifts Included with...

Page 7: ...e placed in a ventilated crawl space if approved by the local building department AAAAAAAAAA NOTE The blower may be placed with the grill facing down Do not place the blower on its side The maximum le...

Page 8: ...s may be used to offset the chimney to align the chimney or gain clearance to combustibles A maximum four 30 elbows may be used Each elbow must be used in conjunction with a return elbow so the chimne...

Page 9: ...e the chimney penetrates the ceiling use a firestop the chimney must maintain the clearances listed below 5 to the rear of the chimney 4 1 2 to the front of the chimney 2 to the side of the chimney Mi...

Page 10: ...roof and 2 above any portion within 10 measured horizontally This applies to flat and sloped roofs The chimney must have a chimney cap When using a chase to enclose a chimney the chimney termination...

Reviews: