Finalizing
the
Installation
(for qualified installers only)
25
© Travis Industries
4161018
100-01436
External Wiring Installation
Make sure the household breaker serving the fireplace is shut off prior to working on any electrical lines.
Determine a location for the rheostat and combustor temp. display. Place it in a location that may be
reached by the 20’ harness exiting the right side of the fireplace. Mount the included double-gang
junction box in this location.
Route the wire harness from the fireplace to the junction box. Do not route the wire over the top of the
fireplace or within 2” of the chimney.
Route an approved electrical line (e.g. Romex® wire) from the fireplace junction box to the rheostat.
Do not route the wire over the top of the fireplace or within 2” of the chimney.
Power In
Romex(r) (or similar) Wire
NOT INCLUDED
Combustor Temp. Display
Harness (included)
Rheostat
Combustor Temp. Display
(& GreenStart Button)
Junction Box
Cover Plate
(included)