Deco RU SD & Plaza RU SD Installation
5
2. FLOOR PROTECTOR REQUIREMENTS
If the heater is to be placed on or within 500mm of a heat sensitive floor, an
insulated
floor
protector will be required.
The insulated floor protector needs to extend under the heater and in front of the door. See
dimensions for floor protector. Similarly a 200mm extension is required on each side of the
door opening unless the insulated floor protector forms an abutment with a wall or heat shield
at a lesser distance.
The heater and floor protector must be fixed to the floor for seismic restraint. Anchor
points are provided in the feet of the unit.
INSULATED FLOOR PROTECTOR CONSTRUCTION
An
Insulated
Floor Protector shall consist of a minimum thickness of
40mm
consisting of
20mm of an approved insulation material material i.e. 2 sheets of 10mm micorboard or
superlux, 10mm tile backing board and 10mm tiles or similar on the top surface. All joints
on the upper surface should be sealed to prevent spilt ash from contacting any heat-sensitive
material.
FLOOR PROTECTOR DIMENSIONS
WHEN BEING INSTALLED IN A
MASONRY
FIRE PLACE
FLOOR PROTECTOR DEPTH
HEIGHT
FROM FIRE BREAST
Level
520
20
460
40
330 (minimum)
INBUILT FLOOR PROTECTOR DIMENSIONS
WHEN INSTALLING IN A
BUILT IN FIRE CANOPY
(
ZERO CLEARANCE BOX
)
HEIGHT
FROM FIRE BREAST
40mm
500
3. BUILT IN FIRE CANOPY
A Built In Fire Canopy is required if the fire is not being installed into a
masonry fire place.
For Built In Fire Canopy installations see details on pages 6 to 14.
Summary of Contents for DECO RURAL SD
Page 7: ...Deco RU SD Plaza RU SD Installation 7 ...
Page 9: ...Deco RU SD Plaza RU SD Installation 9 ...
Page 10: ...Deco RU SD Plaza RU SD Installation 10 ...
Page 11: ...Deco RU SD Plaza RU SD Installation 11 ...
Page 12: ...Deco RU SD Plaza RU SD Installation 12 ...
Page 13: ...Deco RU SD Plaza RU SD Installation 13 ...
Page 14: ...Deco RU SD Plaza RU SD Installation 14 ...
Page 15: ...Deco RU SD Plaza RU SD Installation 15 Built In Fire Canopy Instructions ...
Page 19: ...Deco RU SD Plaza RU SD Installation 19 ...