Summary of Contents for Contessa AG DRY

Page 1: ...ODBURNER All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior to commencing the installation Failure to follow these instructions may also void your fire insurance and warranty This fire conforms with Ecan Requirements ...

Page 2: ...X Page No Item No Topic 3 1 Warnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 Fitting Seismic Restraints 8 6 Flue Installation 9 Minimum Height of Flue Exit 10 Position of Triangular Baffles Published 15 11 2012 ...

Page 3: ...DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its peak Do NOT burn large quantities of paper or combustible material that would create an extremely hot quick fire USE ONLY DRY WOOD AVOID BURNING WET OR GREEN WOOD THE USE OF ...

Page 4: ...et these standards Any variation from these installation instructions or any doubt about them must be checked against the requirements of the Standards 3 FLOOR PROTECTOR REQUIREMENTS The heater should always be installed on top of its base due to high temperatures sustained over long periods The base must be anchored to both the floor protector and the floor for seismic restraint Anchor points are...

Page 5: ...ve floor an insulated floor protector will be required page 4 HEATER MUST BE INSTALLED WITH A FLUE PIPE SHIELD CLEARANCES A B C D E F G H J K L M N O ON PEDESTAL OR DRAWER 130 280 420 110 100 260 600 420 860 1055 1380 1200 795 600 ON LEGS 130 280 350 110 100 260 600 420 860 985 1310 1130 725 600 Clearances A F K can be reduced BY 30mm provided a Contessa cooktop grill is fitted to the fire ...

Page 6: ... on page 10 8 Replace the rear top casting and refit the front top casting ensuring it fits neatly into the rear sealed channel 9 Refit the stainless steel spigot in the top rear section of the firebox 10 Assemble and fit flue as per instructions page 8 9 A flue shield must be fitted 11 If the option of reducing dimension A to 100mm was used then the optional cooktop grill should be fitted on the ...

Page 7: ...ire box 2 Fit Seismic Restraint brackets 3 Secure both the floor protector and the appliance to the floor using a dyna bolt or similar LEG MODELS 1 Place firebox on leg assembly and fit brackets 2 Locate as per appropriate clearances 3 Secure both the floor protector and the appliance to the floor using a dyna bolt or similar ...

Page 8: ...g screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe can either lowered from the top as a single unit or fed up from the room a length at a time ensuring that all joints are fixed properly 10 Slide the inner casing into place between the outer casing and the flue pipe 11 The flue pipe must extend 200mm above the o...

Page 9: ...Contessa AG Dry 9 ...

Page 10: ...Contessa AG Dry 10 CONTESSA AG DRY IMPORTANT BAFFLES UPON INSTALLATION CHECK THAT THE TRIANGLE BRICKS ON TOP OF THE BAFFLES ARE PLACED AS SHOWN ...

Page 11: ...TSONS LIMITED Manufacturers of Lady Kitchener Contessa Coaster Bronte Royale Viking Encore Zealandia Aqualux Athena Forte Plaza Deco Kompact 98 Niven Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 8430505 Email hothouse firenzo co nz Website www firenzo co nz ...