Bronte Rear Outlet RU
8
7. REAR OUTLET FLUE SYSTEM
INSTALLATION INSTRUCTIONS
AS PER AS/NZ2918:2001
CAUTION
:
Mixing of appliance or flue system
components from different sources or modifying the
dimensional specifications of components may
result in hazardous conditions. Where such action is
considered the manufacturer should be consulted in the
first instance.
WARNING
: The appliance and flue system shall be
installed in accordance with AS:NZS2918:2001 and the
appropriate requirements of the relevant building code or
codes.
1. Position the rear outlet flue stand in fireplace. Adjust
height to align with flue spigot on fire. Check
appropriate dimensions (see page 4). Extend plumb line
from top of chimney, ensuring spigot is in line with top of
chimney. If not, flue pipe offsets will be required.
2. Assemble flue pipes ensuring all seams are in line and
assembly is straight and tight with crimped ends pointing
downwards. Secure flue pipes with at least 3 pop rivets
or self tapping screws.
3. Fasten chimney plate supplied onto the chimney top.
The chimney plate must be weather sealed with silicone
or mortar.
4. Install chimney liner on top of chimney plate.
5. Ensure flue pipe is extended over the chimney liner
by 180mm. Secure top spacer bracket to the flue pipe and
ensure slots fit snugly inside the chimney liner.
6. Slide flashing cone over top of flue, until it rests
firmly over top spacer. Secure with pop rivets or self
tapping screws.
7. Fit anti-down draught cowl. Do NOT secure as it
must be removed for cleaning.
Summary of Contents for BRONTE TOP OUTLET RU