Firenzo Athena-Flush-AG-08 Operator'S Handbook Manual Download Page 4

Flush AG08 Installation 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Athena-Flush-AG-08

Page 1: ... ATHENA FLUSH ATHENA FLUSH AG08 AG08 AG08 AG08 FORTE FLUS FORTE FLUS FORTE FLUS FORTE FLUSH H H H AG08 AG08 AG08 AG08 The Appliance and Flue System must be installed in accordance with AS NZS2918 2001 Consult with the Building Authority having jurisdiction to obtain a permit prior to commencing the installation Failure to follow these instructions may also void your fire insurance and warranty ...

Page 2: ...Page 13 14 Raised Builtin Fire Canopy Framing Guide Page 15 Cavity Chimney Termination Page 18 Insert Flue System for Masonry Fireplace Page 19 Minimum Height of Flue Outlet Page 20 Typical Insert Installation Diagram PAGE ITEM 3 1 Warnings 4 Firebox Fascia Floor Protector Dimensions 5 2 Floor Protector Requirements 6 12 3 Builtin Fire Canopy 13 14 Raised Builtin Fire Canopy 15 Builtin Fire Cavity...

Page 3: ...SE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its peak Do NOT burn large quantities of paper or combustible material that would create an extremely hot quick fire Do NOT burn highly coloured paper or brochures junk mail USE ONLY DRY...

Page 4: ...Flush AG08 Installation 4 ...

Page 5: ...or Protector shall consist of a minimum thickness of 40mm consisting of 20mm of an approved insulation material i e 2 sheets 10mm micorboard or superlux 10mm tile backing board and 10mm tiles or similar on the top surface All joints on the upper surface should be sealed to prevent spilt ash from contacting any heat sensitive material INSERT FLOOR PROTECTOR DIMENSIONS WHEN BEING INSTALLED IN A MASO...

Page 6: ...tallation 6 3 BUILT IN FIRE CANOPY A Built In Fire Canopy is required if the fire is not being installed into a masonry fire place For Built In Fire Canopy installations see the following pages 6 7 8 9 10 11 12 13 14 ...

Page 7: ...Flush AG08 Installation 7 ...

Page 8: ...Flush AG08 Installation 8 BUILT IN FIRE CANOPY INSTRUCTONS FOR NON MASONARY INSTALLATION ...

Page 9: ...Flush AG08 Installation 9 ...

Page 10: ...Flush AG08 Installation 10 ...

Page 11: ...Flush AG08 Installation 11 ...

Page 12: ...Flush AG08 Installation 12 ...

Page 13: ...Flush AG08 Installation 13 ...

Page 14: ...Flush AG08 Installation 14 ...

Page 15: ...Flush AG08 Installation 15 Built In Fire Canopy Instructions ...

Page 16: ... Masonry Fireplace If the mantel shelf on a masonry fireplace is of a combustible material there should be a minimum distance above the top of the fascia of 215mm This may be reduced if a deflector or heat shield is fitted under the mantel MANTEL using BUILT IN FIRE CANOPY FORTE FLUSH Can NOT have a combustible mantel however if the mantel is made of a non heat sensitive material then the minimum ...

Page 17: ...on place 25mm white kaowool blanket supplied on top of casing 7 As this fire sources its combustion air from the chimney cavity enclosure the fire MUST be sealed around the front between the casing and the masonry or inbuilt canopy This is achieved by packing the yellow ISB insulation supplied between the casing and the masonry or inbuilt canopy at the FRONT ONLY to maximum depth of 90mm UNDER NO ...

Page 18: ...the chimney top The chimney plate must be weather sealed with silicone or mortar 4 Install chimney liner on top of the chimney plate 5 Ensure flue pipe is extended over the chimney liner by 180mm Secure top spacer bracket to the flue pipe and ensure slots fit snugly inside the chimney liner 6 Slide flashing cone over top of flue until it rests firmly over top spacer Ensure ventilation gap is not c...

Page 19: ...Flush AG08 Installation 19 ...

Page 20: ...Flush AG08 Installation 20 ...

Page 21: ...ll 7 Remove cast ash lip from the firebox and fit below the door with the attached screws 8 Refit the lower steel grill 9 Fit control knob FORTE WITH FLUSH DOOR 1 Remove all items from packaging and separate 2 Remove screws fixed to the lugs on the firebox side 3 Place fascia against body 4 Position infills each side of the door 5 Replace screws into body lugs securing the fascia and infills 6 Rem...

Page 22: ...ODFIRES by HEWITSONS LIMITED Manufacturers of Lady Kitchener Contessa Bronte Viking Royale Zealandia Coaster Athena Forte Plaza Deco 68 Austin Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 8430505 Email hothouse firenzo co nz Website www firenzo co nz ...

Reviews: