Firenzo Woodfires 102107 Installation And Operation Manual Download Page 29

Forte Flush & Athena Flush AG/RURAL 

-

 November 2018

 

 

 29

 

 

 

 

10

 

For  information  (including  claim  procedures)  concerning  potential  claims,  potential         

warranty claimants should contact: 

 

          

-

 in the first instance, the retailer/dealer from whom the Firenzo wood fire was  originally          

purchased or 

 

-

  (if  the  retailer/dealer  is  not  contactable  or  does  not  address  the  claim  to  the        

claimant

s satisfaction) Firenzo at the specified address, 

 

including as appropriate to arrange an inspection of the Firenzo wood fire.

 

11

 

After complying with paragraph 10, for valid claims, a warranty claimant must submit a 

comple  ted  warranty  claim  form  (please  see  Firenzo

s  website,  or  contact  Firenzo,  for  this 

form)  or  other  form  acceptable to  Firenzo  providing  details  of  the  consumer

s  warranty  from 

the      Warranty Registration Card (including its date of issue) and specifying the defect: 

 

-

 to the retailer/dealer from whom the Firenzo wood fire was originally purchased; or

 

-

 to Firenzo at the specified address.

 

12

 

The warranty claimant is responsible for paying any service call fees, transport charges 

and for  any  damages  and  loss  incurred  in  transit  to  the  Firenzo  wood  fire  or  its  component 

parts  and  materials,  to and from  Firenzo  or  its  designated  accredited  agent. Where  Firenzo 

honours a warranty, as  described in paragraph 13, it will reimburse the warranty claimant any                      

transportation costs they have incurred.

 

13

 

Firenzo  or  its  designated  accredited  agent  (please  see  paragraph  16)  will  replace  any   

component parts and materials covered by the warranties or the entire Firenzo wood fire, at its 

discretion,  where  Firenzo  is  reasonably  satisfied  a  defect  is  solely  due  to  faulty  Firenzo          

workmanship or materials.

 

14

 

Firenzo may decline (in whole or part) to honour a warranty claim:     

 

-

 until any amounts due but unpaid by a consumer in respect of the Firenzo wood fire 

or its     servicing are paid.

 

-

  until  Firenzo  is  provided  with  the  applicable  compliance  and  installation  permits 

(please see below);

 

-

 if it appears to Firenzo that the Firenzo wood fire has:

 

-

 not been installed correctly at the specified residential address, or not been  

 

 operated  and  maintained  strictly  in  accordance  with  the  manufacturer

s            

instructions, AS/NZS 2918:2001 and any relevant building code or consent 

or these warranty terms.

 

not  been  inspected  and confirmed  after  installation  as a compliant  installation 

(with the requisite specifications and permits);

 

not been regularly maintained and at least annually serviced;

 

-

 been subject to misuse, neglect, or accident in transit, storage or use.

 

-

 been damaged by water ingress in any way, including any surface rust which 

has     occurred in transit or storage. However this exclusion will not apply 

to any damage to the Firenzo wood fire which is determined to have been 

caused by wetback leakage attributable to faulty Firenzo component parts 

or materials  or  workmanship;.

-

  been  over fired  or  has  used any fuel  other 

than  clean  dry  firewood  (having  25%  or  less  moisture  content),  including 

any  chemically treated timbers or driftwood. 

 

-

  if  it  appears  to  Firenzo  that  the  defect  is  attributable  to  a  failure  to  replace             

consumable  parts  or components  or materials within a  timely manner to maintain 

their durability. 

 

Summary of Contents for 102107

Page 1: ...someone competent to do so Firenzo recommend the use of a NZ Home Heating Association solid fuel Fire installation technician SFAIT or other suitably qualified person The Fire and Flue System must be installed in accordance with AS NZS2918 All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior...

Page 2: ...17 6 Assembly Instructions 18 Typical Insert Installation 19 7 Wetback 20 8 Insert Flue System 21 Fascade Chase Termination 22 Minimum Height of Flue Outlet 23 9 Fascia Assembly Installation 24 10 Operating Instructions 25 Operating Instructions 26 11 Maintenance 27 12 13 Maintenance 28 30 14 Warranties Your Warranties Registration Card is enclosed please complete and return to us Under our policy...

Page 3: ...o not use FLAMMABLE LIQUIDS or AEROSOLS in the vicinity of this Fire when it is operating Use caution when reloading with fuel Do NOT attempt to load fuel into the Fire when the fire inside the stove is at or near its peak Do NOT burn large quantities of paper or combustible material that would create an extremely hot quick fire Do NOT burn highly coloured paper or brochures junk mail USE ONLY DRY...

Page 4: ...hese installation instructions or any doubt about them must be checked against the requirements of the standards Please leave this manual with the owner when installation is complete 3 FLOOR PROTECTOR REQUIREMENTS If the Fire is to be placed on or within 500mm of a heat sensitive floor an insulated floor protector will be required The insulated floor protector needs to extend under the Fire and in...

Page 5: ...stallation the standard front clearance from the fireplace breast brickwork etc can be reduced by increasing floor protector height INSERT FLOOR PROTECTOR DEPTH HEIGHT FROM FIRE BREAST Level 520mm 20mm 490mm 40mm 400mm 60mm 400mm Min FLOOR PROTECTOR DIMENSIONS WHEN INSTALLING IN A ZERO CLEARANCE BOX Built in Fire Canopy HEIGHT FROM FIRE BREAST 40mm 500mm ...

Page 6: ...Forte Flush Athena Flush AG RURAL November 2018 6 ZERO CLEARANCE BOX Built in Fire Canopy Refer page 7 for Built in Fire Canopy Dimensions ...

Page 7: ...18 7 4 ZERO CLEAREANCE BOX Built in Fire Canopy A Zero Clearance Box is required if the fire is not being installed into a masonry fire place For Zero Clearance Box installations see the following pages 7 15 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 8: ...Forte Flush Athena Flush AG RURAL November 2018 8 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 9: ...Forte Flush Athena Flush AG RURAL November 2018 9 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 10: ...Forte Flush Athena Flush AG RURAL November 2018 10 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 11: ...Forte Flush Athena Flush AG RURAL November 2018 11 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 12: ...Forte Flush Athena Flush AG RURAL November 2018 12 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 13: ...Forte Flush Athena Flush AG RURAL November 2018 13 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 14: ...Forte Flush Athena Flush AG RURAL November 2018 14 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 15: ...Forte Flush Athena Flush AG RURAL November 2018 15 ZERO CLEARANCE BOX Built in Fire Canopy ...

Page 16: ...ial MANTEL Masonry Fireplace If the mantel shelf is of a combustible material there should be a minimum distance above the top of the fascia of 400mm This may be reduced if a deflector or heat shield is fitted under the mantel MANTEL using ZERO CLEARANCE BOX Built in Fire Canopy FORTE Can NOT have a combustible mantel however if the mantel is made of a non heat sensitive material then the minimum ...

Page 17: ...e as per instructions on Page 20 21 if installing in a Masonry Fireplace or pages 8 9 10 11 12 15 if using a Zero Clearance Box Built in Fire Canopy 6 Now that the firebox and flue are in position place 25mm White Kaowool Blanket supplied on top of casing 7 As this fire sources its combustion air from the chimney cavity enclosure the fire MUST be sealed around the front between the casing and the ...

Page 18: ...Forte Flush Athena Flush AG RURAL November 2018 18 ...

Page 19: ...Forte Flush Athena Flush AG RURAL November 2018 19 7 WETBACK ...

Page 20: ...equired 2 Assemble flue ensuring all seams are in line and assembly is straight and tight with crimped ends pointing downwards Secure flue with at least 3 stainless steel or monel rivets and seal 3 Fasten chimney plate supplied onto the chimney top The chimney plate must be weather sealed with silicone or mortar 4 Install chimney liner on top of the chimney plate 5 Ensure flue is extended over the...

Page 21: ...Forte Flush Athena Flush AG RURAL November 2018 21 ...

Page 22: ...p of the floor protector 2 The flue cowl must be at least 600mm above the highest point of the roof if within 3 me tres of it or 1 metre above the roof penetration if more than 3 metres from the ridge 3 No part of the building or any adjacent building may be in or above a circular area of a horizontal radius of 3 metres from the flue exit ...

Page 23: ...o 6mm screws in body and tighten 7 The screw on the bay section may now require adjusting to support canopy 8 Fit upper cast grill on side locaters FORTE WITH FLUSH DOOR 1 Remove screws fixed to lugs on firebox side 2 Place pre assembled fascia against firebox position left hand slip behind hinges and secure the screw Place right hand slip against fascia and secure 3 Set the machine screw on the t...

Page 24: ...5 Open door carefully and place small pieces then larger logs on top 6 Close door tight and leave Air Control on HIGH for some 30 minutes The value in establishing this technique is that you are providing an excellent base for burning your wood effectively 7 When a good fire is established move air control to middle position DO NOT IMMEDIATELY SHUT THE FIRE TO LOW Remember to close the air control...

Page 25: ...n an almost empty Fire set at the same position Remember you only get out of any Fire what you put into it The better the fuel the better the Fire Do NOT burn plastic household refuse or driftwood This will void any Warranty and reduce the lifespan of the fire FLAMMABLE LIQUIDS CAUTION Never use gasoline type fuel kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in t...

Page 26: ...note of the manufacturer s instructions for spraying Never spray a hot fire BLACK OR SILVER PLATED RAILS The black or silver plated rails must not come in contact with abrasive materials Use a clean damp cloth when the Fire is cool if cleaning is required FIRE BRICKS The internal fire bricks on the sides and base of the firebox can crack in extreme heat However they are safe to leave as is until t...

Page 27: ...nsulating material for the glass should be replaced at this time also NEVER place glass directly against the door Without the insulation seal tape in place the glass is likely to shatter Your Firenzo agent will be able to supply any spare parts 13 SAFETY All surfaces on the inserts will get hot and cause burning if touched by bare hands Firenzo recommends using a fireguard The heat from inserts wi...

Page 28: ...sumer Guarantees Act 1993 To the fullest extent permitted at law no other warranties or guarantees express or implied are assumed or given by Firenzo to any person with respect to the quality merchantability description or fitness for purpose or use of Firenzo wood fires or their component parts and materials 6 Firenzo is not liable for and to the maximum extent permitted by law excludes any liabi...

Page 29: ...ials covered by the warranties or the entire Firenzo wood fire at its discretion where Firenzo is reasonably satisfied a defect is solely due to faulty Firenzo workmanship or materials 14 Firenzo may decline in whole or part to honour a warranty claim until any amounts due but unpaid by a consumer in respect of the Firenzo wood fire or its servicing are paid until Firenzo is provided with the appl...

Page 30: ...tions about the warranties or this document please contact Firenzo at its specified address on telephone 06 8438260 by email at firenzo firenzo co nz or via the Firenzo website www firenzo co nz 18 This document is intended to form part of and may be expressly referenced in the terms of sale and purchase by every original New Zealand consumer of a Firenzo wood fire With out limiting that intent by...

Page 31: ...tessa Encore Lady Kitchener Napier Viking Vision Insert Aqualux Athena Bay Flush Forte Bay Flush Kompact Athena Kompact Deco Kompact Diva Kompact Forte Kompact Plaza Kompact Serenity Topaz 98 Niven Street PO Box 3231 HB Mail Centre Napier 4142 Phone 06 8438260 Website www firenzo co nz email firenzo firenzo co nz ...

Reviews: