NKL
auditlok xl
®
®
SERVICE MANUAL
12
®
service nOTes
basic TrOUbLeshOOTing
Lost pin:
NKL does not have access to any
PIN nor can a key (or user number) be
made functional without it. If a PIN is lost the
user must be deleted and reenrolled.
damaged Key:
This may be caused by
extreme temperature; exposure to electro-
magnetic fields; immersion in liquid. Delete
any lost or damaged keys.
message
ErrOr
,
iNVALiD UsEr
:
The user is not enrolled, has been deleted,
or the key is damaged.
message
kEy iNActiVE sEE mAN-
AgEr
:
The user is inactive. A manager can
reactivate a user.
display blank and completely inoperative:
Check power supply connections. Verify
power is present at the AC outlet. Verify
power is present at the DIN connector from
the transformer. If the power supply is okay
the problem is the inner board, outer board,
internal power supply cable, or communi-
cation cable.
display responds to only some buttons:
Re
-
place the outer board.
display responds normally but there is no
beeping sound when buttons are pressed:
The
buzzer is damaged or disconnected. The
buzzer is located in the cavity behind the
outer board. The buzzer is connected di
-
rectly to the inner board.
continuous tone with doors closed:
A door sen-
sor needs adjustment, has failed or become
disconnected. Log in at the Administrator
level (New XL) or run an override (New or
Old XL) to disable the offending sensor
until it can be adjusted, reconnected or
replaced.
Unable to enroll a user:
The user memory is
full. Delete one or more users. If memory is
not full and/or deleting users does not solve
the problem, run an override to clear the
user table or replace the inner board.
Keyport does not respond:
Replace the outer
board.
erratic behavior or corrupt settings:
Replace
the inner board.
majOr hisTOricaL changes
power supply (Old XL):
In January 2000
NKL switched from a 9V transformer to a
12V transformer. Transformers are not in-
terchangeable due to different connectors
and internal cables. Units with the 9V trans-
former were built with an 8V backup battery
mounted behind the inner board. The bat-
tery backup feature is no longer supported.
An external UPS is recommended for all
installations, past or present.
power supply (new XL):
AuditLok XL requires
less power than AuditLok XLV, however you
may use the AuditLok XLV transformer (part
15000346) if you have one available and do
not have the normal 12V transformer.
gold display (Old XL):
A gold outer board
was used 2001-2003. If a gold outer board
fails it should be replaced with a blue outer
board (15020200).
Keyless Option (Old XL):
Software became
available to support keyless access,
streaming audit output and optional bio-
metrics reader in 2005.
door sensors:
Starting in late 2003 to early
2004 NKL stopped using the switch sensor
mounted behind the door closer and began
using the white magnetic plunger sensor
mounted at the top hinge side of the outer
door. At the same time the same plunger
began being used on the inner door.
dust covers:
In January 2004 the dust covers
were changed for improved quality. New
dust covers cannot be retrofitted onto old
safes.
cam mounting:
In January 2000 NKL began
using washers with a cotter pin to mount
the center cam. Prior to this the cam was
mounted with a capture nut.