NFOD42 Gas Fireplace
INSTALLATION
FINISHING
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into fi nal position - it is important to know the total thickness / height of fi nished hearth. The base of the fi replace should be
level or higher than the fi nished hearth height.
”
18
”
41-1/2”
If material such as brick, stone, etc extends past the faceplate depth (1-1/2"), when fi nishing around the faceplate, the minimum opening dimensions
noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance.
For material such as brick, stone, etc that extend up to 1-1/2" , the minimum opening dimensions noted below must be adhered, when fi nishing around
the faceplate. This is to ensure the removal of the faceplate and for the safe operation of this appliance.
For facing material is over 1” (25mm)thick, use the
outer cut out
for your
faceplate template.
40 1/4”
18”
For facing material is
under
1” (25mm) thick, use the
inner cut out
to keep construction material out of the fi rebox.
16”
38”
HZO42
”
16
”
38-1/16”
Unit shown without faceplate
NFOD42