REV. 8-30-18 Page 5
Linear Outdoor Fire (LOF)
SPECIFICATIONS
Table1
LOF Pan Dimensions
36”
96”
24”
Maximum
Overhang
Center of Flame
Ground Level
A
B
C
D
E
End View
Fig. 1
Linear Pan Dimensions; refer to Table 1.
Fig. 2
Clearance to Combustibles (Not
to be used in an enclosed space)
Model
Btu’s
NG/(LP)
Factory Orifice
NG LP
LOF-30MT-N; LOF-30MSI-N 45,000 Btu’s
#36
#49
LOF-36MT/N; LOF-36MSI-N 75,000 Btu’s
#29
#41
NG
LP
Min.
Inlet
5.0”WC
11.0”WC
Max.
Inlet
10.5”WC 13.0”WC
Table 3
Gas Pressures
Model
A
Pan Depth
B
Min/Max Opening Width - Length
C
Inside Pan
D
Ground Level
LOF-30MT/N; LOF-30MSI-N
2
¾”
6
¼”
- 7
½”
W x 30
¼”
- 31
¾”
L
30”
6”
LOF-36MT/N; LOF-36MSI-N
2
¾”
6
¼”
- 7
½”
W x 36
¼”
- 37
¾”
L
36”
6”
Note:
Linear Outdoor Fire’s are rated at maximum Btu’s which is
dependent upon proper gas pipe sizing. Flex line size also affect
Btu’s. As a result your Btu’s will may vary from Table 2
specifications listed above.
Table 2
Btu Specifications based on 7.0”WC - NG and 10.0”WC -LP