background image

REQUIREMENTS

1.  Only non-combustible materials should come in direct contact with any part of the fire pit. Underneath area should be non-   

     combustible or a flat level combustible surface according to the clearances specified in this manual.
2.   

We recommend using 3/4” black iron pipe; however please refer to the NFPA54 (National Fuel Gas Code) for proper  

      pipe sizing when exceeding 20-feet in length for fire pits rated above 100,000 BTU’s.

3.   Determine the size of the round fire pit you are preparing to install (Refer to page 3).
4.   

You must provide a round opening out to place the flat disc onto the non-combustible enclosure.  Do not exceed the  

       maximum opening from Table 1, dimension B located on page 3.

5.   Follow the local code requirements for the gas type being used. This fire pit should be installed in accordance with           

      local codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1           

       NFPA54 or CSA B149.1, Natural and Propane Installation Code in Canada.
6.   Fire pits create high temperatures, it is very important to have any combustibles at a safe distance. Refer to page 3. 
7.   Normal operation of the fire pit is with a battery pack that is supplied with your system (Fig 19). The battery box has        

      12-feet of black sleeved wire that is to be passed through the junction box provided. This wire should not be cut or  

      spliced and the junction box can be placed in the facing of the vertical finish of the fire pit, if you place the wire under  

      ground you should install those wires into an approved protective conduit/sleeve material.
8.   Fire pit should never be left unattended while in operation. It should always be a safe distance from all trees and                         

     combustible landscape materials. 
10.  Construction of the finished fire pit should be stable and solid. From the bottom of the control box that houses the          

       gas valve and module, it should be a according to specifications on Table #1. 

NOTE

Proper drainage is critical to       

       ensure that water does not damage gas valve and components.

 Never install fire pit below grade.

11.  

CAUTION: The fire pit enclosure MUST have a minimum ventilation of 18 square inches on each side of the            

       finished enclosure.

12.  The insulation square pad provided with the fire pit is to be placed foil up toward the bottom of pan on top of the           

       valve box. 
13.  Never fill the cavity under and around the valve box with any material, this is a provided air space necessary for           

       ventilation. 
14.  These products are designed for outdoor use only. Not approved for any indoor use. 
15.  This fire pit is designed to have decorative rock, lava rock/media covering the burner, so the burner is not visible.  Optional  

        concrete logs can be added to consumers taste. Decorative rock is not provided. When purchasing decorative rock use  

        minimum of 1-inch diameter rock as a base to fill the burner pan. 

DO NOT COVER THE  IGNITION HOOD WITH ANY  

       ROCK OR MEDIA.

16.  Gas lines and fittings must be installed in to the non-combustible structure. All gas connections must be leak tested  

       before installation of the fire pit. Soapy water leak detection is required before regular use of the fire pit.
17.  Do not use material that will absorb moisture over time and will not release this moisture quickly. Moisture can boil in this  

       material and can rapidly break apart and cause damage or personal injury.
18.  Never leave any other combustible material on top of the fire pit. This could cause unsafe operation of this system           

       and damage to the component that will not be covered under the warranty.

INSTALLATION OF FIRE PIT INTO AN APPROVED ENCLOSURE

NOTE

:  Gas valve, flexible gas lines 

and TFS components are supplied.  

Gas shut-off is not supplied. 

Fig. 18  Typical installation.

Valve

Box

Battery Pack 

SECTION C THERMOCOUPLE  FLAME SENSE INST

ALLA

TION

REV. 5-7-14  Page 14

Flat Disc Burning Spur Fire Pits

Summary of Contents for FPB-G34DBSMT-N

Page 1: ...m 18 square inches per side of cross ventilation Failure to provide proper ventilation can void the warranty Natural Gas Description Propane Match Light MT FPB G34DBSMT N 34 G90 Flat Disc Spur Kit FPB G34DBSMT P FPB G44DBSMT N 44 G90 Flat Disc Spur Kit FPB G44DBSTM P Thermocouple Manual Safety TMS FPB G34DBSTMS N 34 G90 Flat Disc Spur Kit FPB G34DBSTMS P FPB G44DBSTMS N 44 G90 Flat Disc Spur Kit F...

Page 2: ...3 B2392 254 8 C D438E 3F 38 58 897 4 4659 958 G377 H C I 4 F234 56673589 38 58 897 4 4659 4 92 54 5 95 6 J F 8FJ 95 2 C 03 2 1 02 2 03 2 01 902 2 0 7 90 A 21 1 6 2 1 0 9 2 61 6 10 7 A 6 1 2 B 1 1 7 03 K L D M K 1L 0 1 1 2 1 03 1 4 5 6 1 7 28 27 2 03 5292 20 032 1 03 1 66 2 9 61 6 1 2 0 02 A 7B 0 0A 0 1 02 A 1529 1 2 0 9 9 9 2 B 1 1 61 6 10 7 C 7 03 2 0 02 A 6 1 02 7 2 0 9 2 01 902 03 1 3 4 1 2 0 2...

Page 3: ...17 Thermocouple Flame Sense 19 20 Optional Accessories 18 TABLE OF CONTENTS Flat Disc Burning Spur Fire Pits Fuels used in gas fired appliances and the products of combustion such as fuels contain chemicals known to cause cancer birth defects and or other reproductive harm This warning is issued pursuant to the California Health Safety Code Sec 25249 1 NOTE This installation instruction covers 3 d...

Page 4: ...odel Propane Gas LP A Disc Depth B Pan Diameter C Min Max Install Opening D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor FPB G34DBSMT N FPB G34DBSMT P 0598 34 24 31 18 19 69 18 FPB G44DBSMT N FPB G44DBSMT P 0598 44 24 40 18 19 69 18 FPB G34DBSTMS N FPB G34DBSTMS P 0598 34 24 31 18 19 69 18 FPB G44DBSTMS N FPB G44DBSTMS P 0598 44 24 40 18 19 69 18 FPB G34DBSTFS N FPB G34DBSTFS...

Page 5: ...rior house wall If pipe is to pass through a foundation or house wall make sure to re seal the area around the pipe with weather sealant 3 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or g...

Page 6: ...REV 5 7 14 Page 5 Flat Disc Burning Spur Fire Pits Section A Match Light Installation ...

Page 7: ...ring the spur burner so that the burner is not visible Do not cover more than 1 above the top of the burner When purchasing lava rock use 1 diameter as a base to cover the flat disc 10 Gas lines and fittings must be installed in to the non combustible structure All gas connections must be leak tested before installation of the fire pit Soapy water leak detection is required before regular use of t...

Page 8: ... not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple SECTION A MATCH LIGHT MT INSTALLATION Landscape Patio Block Illustration Shows possible ventilation Illustration depicts flat disc shaded area unde...

Page 9: ...fuel supply connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 8 Inserting Key into Valve O N O F F Fig ...

Page 10: ...REV 5 7 14 Page 9 Flat Disc Burning Spur Fire Pits Section B Thermocouple Manual Safety Installation ...

Page 11: ...age 3 5 Follow the local code requirements for the gas type being used This fire pit should be installed in accordance with local codes and ordinances or in the absence of local codes with the latest National Fuel Gas Code ANSI Z223 1 NFPA54 or CSA B149 1 Natural and Propane Installation Code in Canada 6 Fire pits create high temperatures it is very important to have any combustibles at a safe dis...

Page 12: ... Fig 15 Keep screen cover exposed IGNITOR ALIGNMENT It is important check that the ignitor probes be properly aligned over top of the burner port holes and did not move during shipping Use the Fig 14 as a guide Before lighting remove the screen cover of the ignition hood to burner and ensure the thermocouple is directly over top of a burner port hole The sparking probes and the thermocouple must b...

Page 13: ...ppliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS TURNING ON FIRE PIT CAUTION Ensure you have leak tested the fire pit before operating 1 Light a ...

Page 14: ...Section C Thermocouple Flame Sense Installation REV 5 7 14 Page 13 Flat Disc Burning Spur Fire Pits ...

Page 15: ...tom of the control box that houses the gas valve and module it should be a according to specifications on Table 1 NOTE Proper drainage is critical to ensure that water does not damage gas valve and components Never install fire pit below grade 11 CAUTION The fire pit enclosure MUST have a minimum ventilation of 18 square inches on each side of the finished enclosure 12 The insulation square pad pr...

Page 16: ...and install the 4 four AA batteries 6 Be sure the batteries are installed positive to positive and negative to negative If one battery is installed wrong the system will not operate 7 Once the fire pit is installed into the enclosure the burner and control system should be tested before the media lava rock is installed INSTALLATION OF BATTERY INTO TRANSMITTER You have one handheld transmitter and ...

Page 17: ... electronic module up to a total of three transmitters are available Contact Firegear to discuss additional transmitter options or see the accessory page of this instruction manual Learning the new transmitters is simple but will require pressing the learn button on the module You should learn any new transmitters before the final installation of the fire pit Follow the steps below 1 Remove the tw...

Page 18: ...liance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines The direct spark ignition will turn OFF after 15 seconds if the burner does not light after which you will need to press transmitter OFF button then back ON to initiate ignition again Flame height is HI and LO By pressing the buttons on the handheld transmitter you can operate ON OFF HI L...

Page 19: ...Replacement Parts Maintenance Accessories REV 5 7 14 Page 18 Flat Disc Burning Spur Fire Pits ...

Page 20: ...ery cover slides on off Latching Solenoid DC Motor Drive 10 11 12 13 S I Remote Off ADJ IPI POWER AUX Learn Module 17 19 AA Batteries AA Batteries AA Batteries AA Batteries 20 18 5 7 LOW HI OFF ON 25 4 6 O N O F F 15 14 16 21 22 23 24 28 29 30 REV 5 7 14 Page 19 Flat Disc Burning Spur Fire Pits ...

Page 21: ...lot 1 ST3 040 1025 x 15 Thermocouple Bracket Must be ordered with TFS item 14 1 ST3 100 1054 x 16 Ignitor Probes 1 VCS 5000DSI2P01 x 17 Ignition Module 1 VCS 5000MODTC x 18 Ignition Hood for Spur Burner 1 ST3 100 1057 x x 19 Mesh Screen Cover 1 ST3 100 1027 x x 20 AA Batteries 1 5 Volt used in battery pack 4 AA Batteries x 21 Valve Mounting Plate used with item 9 1 ST3 100 1058 x 22 Valve Box Stai...

Page 22: ...use Sooting may also occur periodically on the screen of the ignitor hood To clean brush off with a dry bristle brush or cloth Keep soot away from clothing or furniture 6 Over time galvanized parts can discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TROUBLE SHOOTING FOR MT TMS MODELS Sympton Remedy Fire pit won t ...

Page 23: ...odels only Model 1322 WT Wireless 4 button timer 30 60 120 OFF TFS models only Model TMR AF1 Wireless wall switch ON OFF TFS models only Model 1001D A Model LPK 41 LP Conversion Kit is for use with listed models below Kit Includes OAS rating plate sticker and instructions For Use With Models FPB G34DBSMT N FPB G34DBSTMS N FPB G44DBSMT N FPB G44DBSTMS N NOTE There is no LP conversion kit for Thermo...

Page 24: ...ame sensing 5 Ensure orange white leads from module are plugged into the PILOT connection on the valve body 6 Ensure green white leads from module are plugged into the MAIN connection on the valve body 7 Verify lead from igniter on electrode assembly is connected to the I terminal on the module 8 Verify lead from flame sensor on electrode assembly is connected to the S terminal on the module 9 Ver...

Page 25: ...en the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system is in the ON position but does not sense a flame 2 Make sure that the flame sensor electrode is clean Soot buildup will insulate the electrode and will not allow for proper flame sensing 3 Make sure that wind does no...

Page 26: ... 855 498 8324 Firegear Outdoors 9230 Conservation Way Fort Wayne IN 46809 For Sales 888 672 8929 Tech Support E mail www support skytechpg com WEB SITE www firegearoutdoors com REV 5 7 14 Page 25 Flat Disc Burning Spur Fire Pits ...

Reviews: