SPECIFICATIONS
A
B
C
.875 TYP. (usable flat lip)
*
*
D
Ground Level (Earth)
Figure 1. Fire pit dimensions; refer to Table 1. (Dimensions applicable to
round or square pans)
36”
96”
24”
Maximum
Overhang
Center of Flame
Figure 2. Clearance to Combustibles
(Not to be used in an enclosed space)
REV. 7-22-14 Page 4
Table1. Fire pit dimensions
Model
:
Match Throw (MT)
A
Pan Depth
B
Min/Max Cutout
C
Inside Pan
D
Ground Level
FPB-19RFSMT-N
2.625”
19.25”/21.5”
19”
8”
FPB-25RFSMT-N
2.625”
25.25”/27.5”
25”
8”
FPB-14SFSMT-N
2.625”
14.25”/15.75”
14”
8”
FPB-20SFSMT-N
2.625”
20.25”/21.75”
20”
8”
FPB-26SFSMT-N
2.625”
26.25”/27.75”
26”
8”
FPB-32SFSMT-N
2.625”
32.25”/33.75”
32”
8”
FPB-38SFSMT-N
2.625”
38.25”/39.75”
38”
8”
FPB-G29RFSMT-N
2.750”
30.00”/31.25”
29.5
8”
FPB-G33RFSMT-N
2.750”
34.00”/35.25”
33.5
8”
Note:
Btu listings are based on 7.0”WC for Natural Gas and 11.0”WC
for Liquid Propane (LP) at the burner orifice. Flex line size and
proper gas pipe sizing will also affect Btu’s. As a result your Btu’s
may vary slightly from Table 2 specifications.
Firestar Fire Pits
Model:
Match Throw
BTU/H
Natural/Propane (LP)
Factory Orifice
NG LP
FPB-19RFSMT/N
60,000 Btu/H
#31
#45
FPB-25RFSMT/N
100,000 Btu/H
#22
#35
FPB-14SFSMT/N
36,000 Btu/H
#42
#52
FPB-20SFSMT/N
60,000 Btu/H
#31
#45
FPB-26SFSMT/N
100,000 Btu/H
#22
#35
FPB-32SFSMT/N
160,000 Btu/H
#8
#29
FPB-38SFSMT/N
183,000 Btu/H
#3
#25
FPB-G29RFSMT-N
100,000 Btu/H
#22
#35
FPB-G33RFSMT-N
160,000 Btu/H
#8
#29
Table 2: Btu/H Specifications
Pressure
NG
LP
Min. Inlet
3.5” WC
8.0” WC
Max. Inlet
10.5” WC 13.0” WC
Normal Inlet 7.0” WC
11.0” WC
Table 3. Gas Pressures