Firegear B360EXSSA11-N Installation And Operation Instructions Manual Download Page 16

 

16 

FIREGEAR REVOLUTION LIQUID PROPANE HEARTH KIT PARTS LIST 

Shown in black steel 

– actual unit is constructed of 304 Stainless Steel

 

 

 

 

PART NUMBER 

ITEM 

DESCRIPTION 

 

 

 

48-38-38FL 

VALVE OUT 

– LP ONLY - BRASS HEX NIPPLE – 3/8 MALE X 3/8 MALE FLARE 

49-38-38FL 

REGULATOR INPUT FEED 

– BRASS HEX ELBOW – 3/8 MALE X 3/8 MALE FLARE – LP ONLY 

49-38-38FL/T 

ORIFICE MOUNT 

– BRASS HEX ELBOW – 3/8 MALE X 3/8 MALE FLARE – TAP ½ 20 FOR ORIFICE – LP ONLY 

DC-1 

– COMMON PARTS PAGE 

DAMPER CLAMP 

GL-REV/10 

VALVE TO BURNER GAS LINE 

– 10” – REVOLUTION 360 LP ONLY – 420 NG ONLY 

GL-REV/12 

VALVE TO BURNER GAS LINE 

– 12” – REVOLUTION 420 – LP ONLY 

FG-AF1000S 

15 

AMERICAN FLAME VALVE SOLENOID - REMOTE OPERATION ONLY 

HBR-360/A 

HEARTH BURNER REVOLUTION - 24" 360 BURNER - GRATE ASSEMBLY 

HBR-420/A 

HEARTH BURNER REVOLUTION - 30" 420 BURNER - GRATE ASSEMBLY 

IM-REVA11 

– COMMON PARTS PAGE 

INSTRUCTION MANUAL 

– REVOLUTION AF-1100 – ON / OFF REMOTE 

NIP-INS/2 

12 

REVOLUTION 

– 2” NIPPLE FROM REGULATOR TO VALVE – LP ONLY 

OR-S/52 

#52 BRASS ORIFICE 

– STEM TYPE – ½ 20 THREAD – ½ HEX – 420 LP 

OR-S/53 

#53 BRASS ORIFICE 

– STEM TYPE – ½ 20 THREAD – ½ HEX – 360 LP 

PI-1 

17 

PIEZO IGNITER 

PIW-18 

18 

PIEZO IGNITER WIRE 

– 18” 

REG-10 

11 

REGULATOR - 10.0" W.C. - LP 

REV-EMB 

– COMMON PARTS PAGE 

REVOLUTION - EMBERS - ROCK WOOL 

FG-CINDER 

– COMMON PARTS PAGE 

REVOLUTION - LAVA ROCK 

SPGL-R360/ODS 

SAFETY PILOT GAS LINE 

– REVOLUTION 360 / ODS ASSEMBLY 

SPGL-R420/ODS 

SAFETY PILOT GAS LINE 

– REVOLUTION 420 / ODS ASSEMBLY 

SE-MF/38 

13 

STEEL STREET ELBOW 

– 3/8” MALE X 3/8” FEMALE – LP ONLY 

SPI-ODS/P 

10 

SAFETY PILOT - ODS - LP - SOURDILLON 

SPS-1 

SAFETY PILOT SHIELD 

– FOR ODS SAFETY PILOT 

SV-1100/ODS 

14 

SAFETY VALVE 

– AMERICAN FLAME – 1100 – NO SOLENOID / ODS THERMO BLOCK 

SV-1110/ODS 

14 

SAFETY VALVE 

– AMERICAN FLAME – 1110 – WITH SOLENOID / ODS THERMO BLOCK 

SVA-BC 

16 

SAFETY VALVE AUXILLIARY - BRASS CAP - MANUAL OPERATION ONLY - NO SOLENOID 

SVAF-MB/P 

SAFETY VALVE MOUNTING BRACKET - REVOLUTION - AM FLAME 

– PIEZO MOUNT 

SVE-AF 

– OPTIONAL  

ACCESSORY PAGE 

SAFETY VALVE EXTENSION 

– OPTIONAL ACCESSORY 

WC-FG 

– COMMON PARTS PAGE 

WARRANTY CARD - FIREGEAR 

 

12 

13 

16 

15 

18 

17 

10 

11 

14 

Summary of Contents for B360EXSSA11-N

Page 1: ...adian Standards Association CSA certification numbers for the gas and ignition systems used with firegear outdoor gas log systems The valve systems are manufactured by Skytech II Inc The complete syst...

Page 2: ...EVER use liquid propane gas in a natural gas unit or natural gas in a liquid propane unit DO NOT use solid fuel or lighter fluid in any gas appliance Keep appliance area clear and free from combustibl...

Page 3: ...ons LOG FRONT DEPTH HEIGHT MINIMUM SET WIDTH IN IN IN VENT IN SIZE INCHES INCHES INCHES SQ INCHES FG 360A11 30 14 19 25 7 sq in FG 420A11 36 14 20 33 8 sq in FOR OUTDOOR USE ONLY MINIMUM FIREPLACE DIM...

Page 4: ...afe Installation 12 or more Non combustible material Less than 12 Non combustible material must be extended to at least 8 with the installation of the optional fireplace hood If you can not extend non...

Page 5: ...d with unvented gas logs WARNING Any modification to this unvented gas heater or its controls can be dangerous Improper installation or use of the heater can cause serious injury or death from fire bu...

Page 6: ...onnected from the gas supply piping system during any system pressure test in excess of PSI 3 5 KPA Use a system manual shut off valve to shut off the gas supply to this gas appliance before continuin...

Page 7: ...k steel actual unit is constructed of 304 Stainless Steel FIGURE 11 REVOLUTION BURNER ASSEMBLY ANGLE VIEW Shown in black steel actual unit is constructed of 304 Stainless Steel WHEN INSTALLING THE APP...

Page 8: ...stable pipe wrenches one wrench on the gas stub and one wrench on the fitting remove the existing cap or gas jet assembly from the gas stub in your fireplace by turning the wrench on the gas cap in a...

Page 9: ...Free Burner Systems use 1 The American Flame AF 1100 Series Valves AF 1110 shown here with remote solenoid shown separately in diagram All systems use only an ODS safety pilot with a thermocouple SEE...

Page 10: ...R REAR VIEW FIGURE 17 HAND HELD REMOTE RECEIVER TOP VIEW IMPORTANT TERMINAL BLOCK CONNECTIONS FOR HAND HELD TRANSMITTER REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 16 17 WAL...

Page 11: ...s Logs Box Two before continuing with FINAL SET UP step 2 2 Remove all contents from the Decorative Gas Log shipping container Box Two 3 Check the contents of the shipping container against the shippi...

Page 12: ...unit See Figure 27 28 29 Follow these instructions exactly when lighting the appliance BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor as LP gas is heavier t...

Page 13: ...anual shut off valve and recheck all gas connections for leaks Do not continue until all leaks are corrected Once you are assured that there are no leaks proceed with step seven 7 7 Locate the pilot p...

Page 14: ...wo 2 inches and allow the flame to burn for another thirty 30 minutes Continue this procedure at thirty 30 minute intervals for a total of three 3 hours MAINTENANCE SERVICE Your firegear Decorative Ga...

Page 15: ...ASS ORIFICE STEM TYPE 20 THREAD HEX 420 NG OR S 37 5 37 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 NG PI 1 14 PIEZO IGNITER PIW 18 15 PIEZO IGNITER WIRE 18 REG 35 9 REGULATOR 3 5 W C NG REV EMB A COMMO...

Page 16: ...E FROM REGULATOR TO VALVE LP ONLY OR S 52 5 52 BRASS ORIFICE STEM TYPE 20 THREAD HEX 420 LP OR S 53 5 53 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 LP PI 1 17 PIEZO IGNITER PIW 18 18 PIEZO IGNITER WIRE...

Page 17: ...s When ordering parts first obtain the Model Number from the name plate on your equipment then determine the PART NUMBER not the Index Number and the part description of each part from the parts list...

Page 18: ...Check gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Faulty Regulator Replace...

Page 19: ...covered by this Limited Warranty Before returning any parts contact firegear Customer Service Center If firegear confirms the defect and approves the claim firegear will replace such parts without cha...

Page 20: ...20 www firegearusa com REVEXSSA11 2 0...

Reviews: