Hot Water Series

5.2 

 

Water System  Installation

5.2.1

  

Water Tank Installation

5.2.2

  

Water Piping Installation

1. The water tank should be put in a place where 

suggested to install the heat pump, the water 

ambient temperature is more higher.

tank and the circulation pump at the same level. 
Besides, the height difference between the heat 

2. It can be installed either outdoors or on the 

pump and the water tank should be no more than 

roof-top (some elements such as the size of 

2 meters, when water tank position is higher than 

water tank and the bearing capability of the 

that of the heat pump.

building should be considered). Installation on 
roof-top should be based on support such as 

4. Do not install the water tank in a pollutive or 

crossbeam or pillar.

corrosive area.

3.The water tank should not be installed lower 
than the foundation of the heat pump; It is 

1.

 Drainpipe and overflow pipe should be 

carried out for the water supply valve and the 

installed near the gutter or the sinkhole for 

stop valve of the system (according to local 

draining water more efficiently. Discharge valve 

ambient temperature) for avoiding icing of the 

is necessary on the drainpipe.

water supply pipe and the valves.

2. 

Service valve needs to be installed before the 

6. 

Keep the water pipes straight and the pipeline 

magnet-valves on the system pipeline for further 

allocation reasonable; Reduce pipe turnings as 

inspection.

many as possible to reduce water resistance.

3. 

The pressure of the water outlet should be 

7.

 Prevent the pipeline and the connectors from 

between 0.3MPa and 0.6MPa.

water leakage.

4.

 It is recommended to use metal pipeline such 

8. 

The water pressure bearing capability of each 

as stainless steel pipes, internal-plastic pipes, 

part of the piping system should be tested after 

internal stainless steel pipes or copper pipes 

the installation is finished; Drainage should be 

etc; Telescopic issue of the pipeline between 

done to create a clean interior system.

heat pump unit and water tank should be 

9.

 Measures of heat preservation for the hot 

considered if plastic pipeline such as PPR pipe 

water pipeline need to be conducted after 

and ABS pipe etc. is used.

assuring no water leakage.

5.

 In winter, heat preservation may need to be 

11

Water 

Tank

Water 

Tank

Summary of Contents for YASBP-25HL

Page 1: ...25HL YASBP 38HL YASBP 56HL YASBP 90HL Jan 2012s V Presented by Jimmy Zhang Thank you very much for purchasing our air source heat pumps Please read this manual carefully and keep it for future referen...

Page 2: ...Before Commissioning 6 2 Commissioning 5 Installation 5 1 Heat Pump unit Installation 5 2 Water System Installation 5 2 1 Water Tank Installation 5 2 2 Water Piping Installation 5 3 Power Source Insta...

Page 3: ...corrsion hard performance and safety before exit factory water high pressure and unexpected freeze caused by power cut off Simple Maintenance and Serviceability Full access for maintenance or service...

Page 4: ...n 3 91 0 8 3 64 1 2 5 57 R410a Panasonic Rotary 1 55 60 86 0 8 Tube in shell 20 3 4 48 I IPX4 220 1 50 YASBP 25HL 38 43 770 300 490 820 325 520 kW kW A kW A C C L h 3 m h Kpa mm dB A V Ph Hz kg mm mm...

Page 5: ...er Supply Cable Hole Controller Cable Hole Hot Water Series 770 940 Length mm 300 360 Wide mm 490 550 Height mm YASBP 25HL YASBP 38HL Model 4 2 Dimension 3 L H W High Pressure Gauge 940 360 550 YASBP...

Page 6: ...pacity W Return Water Temp 30 Return Water Temp 35 Return Water Temp 40 Return Water Temp 50 Return Water Temp 55 YASBP 25HL Heating Capacity Heating Capacity W Ambient Temp COP Curves 0 1 2 3 4 5 6 1...

Page 7: ...40 R eturn Water Temp 50 R eturn Water Temp 55 YASBP 38HL COP Curve COP Ambient Temp KRS 50B N2 S HeatingCapacity 0 1000 2000 3000 4000 5000 6000 10 5 0 5 10 20 AmbientTemp Heating C apac ity W Return...

Page 8: ...a te r T e m p 3 0 R e turn W a te r T e m p 3 5 R e turn W a te r T e m p 4 0 R e turn W a te r T e m p 5 0 R e turn W a te r T e m p 5 5 YASBP 56HL Heating Capacity Heating Capacity W Ambient Temp...

Page 9: ...y W R eturn W ater T emp 30 R eturn W ater T emp 35 R eturn W ater T emp 40 R eturn W ater T emp 50 R eturn W ater T emp 55 YASBP 90HL Heating Capacity Heating Capacity W C OP C urves 0 1 2 3 4 5 6 10...

Page 10: ...ting Mode High pressure switch High pressure switch Low pressure switch Low pressure switch 4 way valve 4 way valve Suction accumulator Suction accumulator Compressor Compressor Condenser fin tube fin...

Page 11: ...heat exchanger has big heat exchanging area and rational fin distance thus significantly improves heating and defrosting efficiency Fan The exterior motor fan with multiple fan blades is strictly bala...

Page 12: ...y from windows of neighboring buildings and the exhaust air cannot flow back Moreover adequate service clearance should be kept around the unit 6 The unit sould not be installed at places accompanied...

Page 13: ...ing to local draining water more efficiently Discharge valve ambient temperature for avoiding icing of the is necessary on the drainpipe water supply pipe and the valves 2 Service valve needs to be in...

Page 14: ...wire specification 2 3x1 5mm Power Cable LCD controller Sensor Model Water Pump YASBP 25HL YASBP 38HL YASBP 56HL 2 3x1 5mm 2 3x2 5mm 2 3x0 75mm 2 3x0 75mm 2 3x0 75mm 2 3x0 35mm 2 3x0 35mm 2 3x0 35mm 2...

Page 15: ...2 holes at a level parallel to the sight line as picture 3 The hole distance is 60mm diameter is 8mm 4 Place the plastic screws of the enclosure into the hole and use the tapping screw ST4 16 D 1 enc...

Page 16: ...ance with the specification in the manual or on the heat pump nameplate Make sure all power connections and control circuit are in place Make sure the wiring grounding and all terminals are strong and...

Page 17: ...ress them to adjust the value of water temperature clock timer parameters During failure checking and parameter checking press any of them to exit checking Long press them for a few seconds can lock a...

Page 18: ...symbol Auxiliary heat source start Parameter number symbol the figure under is the parameter number Water tank temperature symbol the figure under is the temperature value Clock time setting symbol Pa...

Page 19: ...choose 1 0 11 for water tank temperature setting see 1 on the above picture NOTICE During parameter setting if no operation for more than 8 seconds the interface of the controller panel will automatic...

Page 20: ...Flashing Step 6 Flashing Press or to adjust the hour value Press to select minute and the minute value flashes Press or to adjust the minute value Press to confirm the value and return to main interf...

Page 21: ...the heat pump to switch on at 9 10 and switch off at 12 30 Step 2 Flash Flashing Flashing Step 3 Step 4 Flashing Step 5 Flashing Step 6 Step 1 Press to start ON time setting Press again to select hour...

Page 22: ...ought forward b f Press to select hour and the hour value flashes Press or to adjust the hour value Press to select minute and the minute value flashes Press or to adjust the minute value Step 7 Press...

Page 23: ...K CM R S C Pump GND T S A S C S GND GND GND R S Tank Temp Sensor Ambient Temp Sensor Coil Temp Sensor Exhaust Air Temp Sensor MCU AC L AC N CQC 250VAC 2 5mm 2 N High Pressure Switch Low Pressure Switc...

Page 24: ...ale Fan Pump 4 Way Vale Tank Temp Sensor Ambient Temp Sensor Coil Temp Sensor Exhause Air Temp Sensor AC 220V 1Ph 50Hz Flow Switch Transformer LCD Controller 220V AC 12V AC AC N AC L MCU BK RE BL BL B...

Page 25: ...efore ex factory Users must not adjust it when inspection of the system is required before next the heat pump unit is in use operation Regular inspection is required for the power Users should call th...

Page 26: ...no C Start temperature 10 55 47 no D Exhaust temperature 9 99 ajdusted by technicians E Pipe temperature 9 99 ajdusted by technicians F Reserved 9 99 ajdusted by technicians 10 Ambient temperature 9 9...

Page 27: ...Fill water into the water supply system 2 Discharge air from the water system 3 Open all the valves in the system 4 Clean the water filter Low heating capacity 1 Lack of refrigerant 2 Bad water system...

Reviews: