Congratulations on your purchase of a Firefly Oasis Battery!
The Firefly batteries use a patented carbon Microcell Foam grid structure that is highly resistant
to sulfation and grid corrosion. They have the longest life of any lead acid battery used for deep
cycling, even at extreme temperatures and operation at less than full charge.
The Firefly batteries have many advantages over a traditional lead acid battery:
•
Plate corrosion is inhibited.
•
Plates are resistant to sulfation.
•
The high plate porosity allows the electrolyte to react more efficiently.
Receiving & Refreshing Charge
•
Check the Individual battery voltages , It will be around 12.90 V for a fully charged 12V
Battery G31 Battery and 4.20V for L16 battery.
•
Freshening charge shall be carried out using a CCCV ( Constant current _Constant
voltage charger as per OCV voltage observed on the batteries.
•
In case the OCV (Open circuit voltage) of the battery is less than 12.70 V , the G31
battery needs to be charged @ 14.40 V (2.40 V / cell ) for 12 hrs. before commissioning.
•
In case the OCV (Open circuit voltage) of the battery is less than 4.10 V, the L16 battery
4V 450 Ah block needs to be charged @ 4.80V (2.40 V / cell ) for 12 hrs. before
commissioning
Installation
MOUNTING ORIENTATION
•
Both the G31 and the L16 batteries can be installed in normal orientation or on their
sides with the narrow side down.
SPACE AND VENTILATION
•
The batteries should be installed with a minimum of 1” between batteries to allow for
proper ventilation and air circulation.
•
There also needs to be adequate space in the compartment for ventilation.
•
If possible, mount the batteries on low stand-offs to encourage air circulation around
their bases.
FOLLOW ALL ABYC INSTALLATION GUIDELINES
•
The batteries should be fastened securely and restrained from movement in any
direction.
•
The positive terminals should be protected by a cover or boots.
•
Refer to ABYC standards for more installation guidelines.