Firecom 3010R Installation & Operation Manual Download Page 8

M O D U L A R P L U G I N S T A L L A T I O N

This section describes the installation of the RJ-12 modular
plugs onto the flat CA cable.

1.  Using the cutter blade on the crimping tool (labeled "A" 

in Figure 7), cut the flat CA cable so the cut is clean 
and 90 degrees to the sides of the cable.

2.  Insert one end of the CA cable between the stripping 

blades (labeled "C" in Figure 6) until the end of the 
cable hits the stop (labeled "B" in Figure 7).

3.  Squeeze the handles of the crimping tool together until 

the tool bottoms out.

4.  While holding the handles together, pull the cable out of 

the tool.

5.  The stripped insulation should expose approximately 

3 /16" of wire (Figure 8).

6.  Push a RJ-12 modular plug into the plug holder on the 

crimping tool (labeled "D" in Figure 7) until the release 
tab on the plug locks into position.

7.  Holding the cable so that the printed side of the cable is 

toward the release-tab on the plug, push the cable into 
the plug as far as it will go.

ALWAYS make sure the printed side of the 
cable is facing the release-tab on the RJ-12 
modular plug (Figure 9). This ensures proper 
orientation of the plug on each end of the cable.

8.  Squeeze the tool handles COMPLETELY together. You 

may feel the crimper finish punching the contacts through
the insulation on the wires.

9.  Let the handles spring open.

10. Push down on the release-tab on the RJ-12 modular plug

(Figure 9) and remove the RJ-12 modular plug from the 
crimping tool.

11. Inspect the plug to ensure that the cable is held securely 

in place.

12. Repeat this procedure as necessary to install a RJ-12 

modular plug on each end of the CA cables.

FIGURE 7:

RJ-12 Modular Plug

Crimping Tool

FIGURE 8:

Stripped CA Cable

FIGURE 9:

RJ-12 Modular Plug

6

Remote Head Manual  12/4/03  10:06 AM  Page 8

Summary of Contents for 3010R

Page 1: ...3025R 3020R 3015R 3010R FIRE APPARATUS INTERCOM REMOTE HEAD 3025 REMOTE HEAD I N S T A L L A T I O N O P E R A T I O N M A N U A L Remote Head Manual 12 4 03 10 06 AM Page 1...

Page 2: ...2 way radio in the apparatus MOBILE RADIO INTERFACE CABLE Provides the interface connections between the 3010R Series Intercom Unit and the 2 way radio in the apparatus There are many different cable...

Page 3: ...I O N CA CABLES Six conductor flat cable which connects the 3010R Series Intercom Unit to the HM 10 PP 20 headset modules and the remote heads FIGURE 1 3010R Series System Overview 1 Remote Head Manu...

Page 4: ...he 3020R Intercom REMOTE CONTROL 3025R Part Number 108 1325 00 This will control the 3025R Intercom BRACKET ASSEMBLY Part Number 108 0303 00 Remote Kit MODEL 3015R Intercom Communication Single Radio...

Page 5: ...aying a message that has been recorded by the digital message recorder DMR PLAY LED 3015R 3025R ONLY A green LED which indicates the digital message recorder is playing a recorded message RECORD LED 3...

Page 6: ...in 4 directions Flush to the outside of the mounting plane in the up down and right side direction or through the mounting plane on the back When exiting up down and right a small wire groove is prov...

Page 7: ...the CA cable to the bracket anchors as shown in Figure 6 10 Before installing the bracket to the mounting surface drill a 3 4 hole at the wire location Snap the grommet into the bracket as shown in F...

Page 8: ...se tab on the plug locks into position 7 Holding the cable so that the printed side of the cable is toward the release tab on the plug push the cable into the plug as far as it will go ALWAYS make sur...

Page 9: ...A cable is inserted all the way 2 Make sure the cable ends were installed correctly see Figure 9 on page 6 3 Check that the ribbon cable from the membrane switch is fully inserted into the edge connec...

Page 10: ...does not extend to any other equipment or apparatus to which this product may be attached or connected The foregoing is your sole remedy for failure in service or defects Sonetics Corporation shall no...

Reviews: