background image

FIRECLASS FC490ST

4 Appendix

User Manual  Doc. version 2

11

4

Appendix

4.1

Additional Information

4.1.1

Menu Functions

Low Battery : Indicates Low Battery by using a flashing 
symbol in the bottom right of the LCD display.

CPU Reset : Switch is accessed through a small hole at 
the rear of the unit near the label.

LCD Backlight : The display can also be temporarily illu-
minated by pressing any two buttons simultaneously at 
any time.

4.1.2

Device Type IDs

MAIN MENU 
DISPLAY

ACTIONS

Address Program

Read/Writes the address of the 
connected addressable device.

Reads the stored address map of 
used addresses.

Analogue Values

Displays the analogue values of 
the addressable device.

Measure Temp.

Measures temperature in 
degrees C and F (only available on 
detectors which have a tempera-
ture sensing element).

Measure CO level

For CO detectors only. Gives val-
ues for CO levels in the measuring 
environment. Normal value is 
zero PPM (parts-per-million)

Test All

Performs:

a self test, if the detector has such 
a facility

remote LED output

functional base interface output

Dirtiness

Indicates the contamination level 
of the optical chamber expressed 
as a percentage, where 100% is 
the fault level.

Device Type ID

Displays the device type identifi-
cation value.

Digital Inputs

Displays the status of the digital 
inputs in addressable devices.

Digital Outputs

Allows the user to set the digital 
output of the addressable device.

Table 5: Functional Reference Table 

DESCRIPTION

MODEL

TYPE 
VALUE

Optical Smoke/Heat 
Detector

FC400PH, 
FC460PH

10

Optical Smoke Detector

FC400P, 
FC460P

15

Optical CO Detector

FC460PC

70

Heat Detector

FC400H, 
FC460H

20

Sounder Module

FC430SAM

80

Loop Powered Beacon

FC430SAB

82

Mini-Input Module

FC410MIM

128

Indoor Callpoint

FC420CP

129

Outdoor Callpoint

FC421CP

130

Single I/O Module

FC410SIO

148

Multi I/O Module 3in/4 
out

FC410MIO

194

Contact I/P Module

FC410CIM

145

Detector I/P module

FC410DIM

146

Beam Detector Module

FC410BDM

181

Relay I/F Module

FC410RIM

161

Sounder Output Module

FC410SNM

177

DDM800 Fire &Gas 
Detector Module

FC410DDM

149

Quad Monitored O/P 
Module

FC410QMO

166

Quad I/O Module

FC410QIO

195

Quad Relay Module

FC410QRM

167

LP Sounder Red

FC410LPSYR

183

LP Sounder White

FC410LPSYW

183

LP Sounder IP65

FC410LPSY

183

LP Sounder/Beacon White FC410LPAVW 184

LP Sounder/Beacon IP65

FC410LPAV

184

LP Sounder/Beacon Red

FC410LPAVR

184

Table 6: Type Values 

Summary of Contents for FC490ST

Page 1: ...User Manual 120 515 079_FC D 490ST U Doc version 2 17 March 2015 FIRECLASS FC490ST Loop Service Tool From Software version 1 0 ...

Page 2: ...ghts to this documentation including the contents of the online help are reserved in particular but not limited to the rights of copying distribution and translation No portion of this documentation including the online help may be reproduced edited copied or distributed in any form without prior written authorization from Tyco Fire Security GmbH ...

Page 3: ...ns 7 2 2 4 EMC Specifications 7 3 Operating Instructions 8 3 1 Charging Batteries 8 3 2 Password Protection 8 3 3 Connecting to a device 8 3 4 Button Operation 9 4 Functionality 11 4 1 ADDRESS PROGRAM 11 4 1 1 ANALOGUE VALUES 11 4 1 2 MEASURE TEMP 12 4 1 3 MEASURE CO LEVEL 12 4 1 4 TEST ALL 12 4 1 5 DIRTINESS 12 4 1 6 DEVICE TYPE ID 12 4 1 7 DIGITAL INPUTS 13 4 1 8 DIGITAL OUTPUTS 13 4 1 9 Additio...

Page 4: ...Contents FIRECLASS FC490ST 4 User Manual Doc version 2 ...

Page 5: ... detection system They should already have been given training Keyword Symbol Explanation DANGER Warning Imminent danger Death or severe injury when disregarded WARNING Warning Potentially dangerous situa tion Death or severe injury possi ble when disregarded CAUTION Warning Potentially dangerous situa tion Minor injury possible when disregarded NOTICE Warning Potentially dangerous situa tion Mate...

Page 6: ...h a shoulder strap The FC490ST has four external connections DC IN 12 V External connection from the car ciga rettelighter or110 230VACuniversalmains adaptor AUX External connection from the Ancillary connec tion port PC PC connection port not used P Microprocessor Connector not used Detectors are programmed by placing the detector onto the FC490ST and turning clockwise until fully engaged Ancilla...

Page 7: ...MC Specifications The FC490ST meets the requirements of the EU EMC Directive 89 336 EEC Parameter Value Operating Temperature 0 C to 45 C Storage Temperature 0 C to 50 C Relative Humidity 90 non condensing Battery Disposal Should be disposed of in accordance with local regulations Table 4 Environmental Specifications ...

Page 8: ...dstandsforEnglishversion appro priate letters are used for other languages The FC490ST then displays the screen below The FC490ST requires a 6 digit password to be entered The password uses only the digits 1 to 4 and may be entered by pressing the corresponding buttons F1 to F4 example button F1 to enter 1 button F2 to enter 2 etc The password is 121234 On successful entry of the password the main...

Page 9: ...referable Connections It is good practice to Connect only a detector or an ancillary at any one time However the FC490ST is equipped with a port interlock feature When the ancillary lead is connected to the AUX socket communication with the detector will be disabled When the ancillary lead is removed the detector will be able to commu nicate The FC490ST may be connected to an ancil lary device tha...

Page 10: ...n in Fig 6 Thebottom linedisplaysinformationtotheuser Thetop line displays the available options In some cases there may be fewer options available In Fig 8 pressing F1 selects the Menu Fig 6 Example of Writing an address F1 Selecting Back F2 Selecting Write F3 Selecting Dn for down F4 Selecting Up Fig 7 Example of Reading an address F1 Selecting Menu F2 Selecting Write F3 No action F4 Clear used ...

Page 11: ...llowed by Having programmed an address the FC490ST moves to the next unused sequential address If an address has already been used the FC490ST indi cates If the user then decides to use a previously used address the following screen is displayed Press Write and the FC490ST displays PRO GRAMMED OK briefly and then displays the next availa ble sequential address 4 1 1 ANALOGUE VALUES ANALOGUE VALUES...

Page 12: ...lect the TEST ALL menu to begin WAIT is displayed until all tests are completed When the tests are complete the test results are reported on three alternating displays Self Test is available only on the following types of detector FC400PH Optical Heat Optical sensing element only FC460PHOptical Heat Opticalsensing element only 4 1 5 DIRTINESS This option is only available for detectors with an opt...

Page 13: ... firmation of the action to send the data to the device as fol lows Select Yes and the LED should illuminate red 4 1 9 Additional Functions DEVICE POLLING In all operations that retrieve data from an attached device theFC490STpollstheattacheddeviceatapre determined interval This interval is 2 seconds for the ADDRESS PRO GRAM function and 5 seconds for all other functions LOW BATTERY This is indica...

Page 14: ...erintothepinholeonthebottomof the FC490ST to actuate a switch When a CPU reset is carried out the FC490ST will start up as described in 3 2 Password Protection 4 1 10 Ordering Information Accessory Kit 516 800 923 Consisting of Carry case Car lighter adaptor Shoulder strap 4 1 11 Spares Spare ancillary lead 516 800 922 Ancillary lead spare pins bag of 10 516 800 924 CPU Reset This function is not ...

Page 15: ...evel of the optical chamber expressed as a percentage where 100 is the fault level Device Type ID Displays the device type identifi cation value Digital Inputs Displays the status of the digital inputs in addressable devices Digital Outputs Allows the user to set the digital output of the addressable device Table 5 Functional Reference Table DESCRIPTION MODEL TYPE VALUE Optical Smoke Heat Detector...

Page 16: ...Company stamp Further information about FIRECLASS can be found on the Internet at www fireclass net 120 515 079_FC D 490ST U doc version 2 17 March 2015 Subject to change without notice ...

Reviews: