16
TECHNICAL INFORMATION
Detector Specifications:
Model CO-9X
Sensor Type:
Electrochemical
Sensor Life:
7 Years
Alarm Sound Level:
85dB at 1 metre (3 feet)
Power Pack Life:
7 years (Life of product)
Temperature Range:
-10ºC (14ºF) to 40ºC (104ºF)
Operating Humidity Range: 30 - 90% RH
Weight:
90 grams (3.2oz)
Certified to:
EN 50291-1: 2010, EN 50291-2: 2010
This FireAngel carbon monoxide detector is designed to continuously monitor for CO.
Its response times meet the requirements of European standard EN 50291-1: 2010 and
EN 50291-2: 2010.
The alarm will sound:
•
Between 60 and 90 minutes when exposed to 50ppm of CO.
•
Between 10 and 40 minutes when exposed to 100ppm of CO.
•
Within 3 minutes when exposed to CO levels of 300ppm or more.